HomeMy WebLinkAbout036_A2.3 BUILDINGS 3-6 - TERRACE FLOOR PLANREF.REF.242322212019181716151413242322212019181716151413151413121110987654321151413121110987654321OPEN TO BELOWROOF TERRACE30-0 X 17-6ROOF TERRACE30-0 X 17-669' - 0"34' - 6"34' - 6"22' - 0"18' - 0"40' - 0"3' - 6"27' - 4"3' - 8" 3' - 8"27' - 4"3' - 6"69' - 0"BALCONY33-5 X 4-0BALCONY33-5 X 4-042" HIGH WALLHOSE BIBHOSE BIBGUARDRAIL (36" H MIN.)GUARDRAIL (36" H MIN.)42" HIGH GUARDRAIL42" HIGH GUARDRAILOPEN TO BELOW72" X 30"SLIDER(6' -8") HEAD72" X 30"SLIDER(6' -8") HEAD36" x 80"FULL LITETEMPERED72" X 30"SLIDER(6' -8") HEAD36" x 80"FULL LITETEMPERED72" X 30"SLIDER(6' -8") HEAD6' - 2"11' - 4"11' - 4"5' - 8"5' - 8"11' - 4"11' - 4"6' - 2"34' - 6"34' - 6"1A4.12-HR FIRE PARITION TYPICAL BETWEEN DWELLING UNITS5A4.117' - 6" 4' - 6"22' - 0"18' - 0"40' - 0"17' - 6" 4' - 6" 6' - 0" 12' - 0"5' - 0"29' - 6"5' - 0"29' - 6"42" HIGH GUARDRAIL42" HIGH GUARDRAILGAS FOR BBQ. LOCATION T.B.D.GAS FOR BBQ. LOCATION T.B.D.15R @ 7 3/4", 14T @ 10"15R @ 7 3/4", 14T @ 10"GUARDRAIL (36" H MIN.)GUARDRAIL (36" H MIN.)HANDRAIL ON AT LEAST ONE SIDE OF THE STAIRS. 34"-38" IN HEIGHT WITH A GRIPPING SURFACE PER R311.7.8.5.HANDRAIL ON AT LEAST ONE SIDE OF THE STAIRS. 34"-38" IN HEIGHT WITH A GRIPPING SURFACE PER R311.7.8.5.FLOOR AREASPER UNIT1ST FLOOR (COMMERCIAL): 1,317 SF GROSS2ND FLOOR (RESIDENTIAL): 1,177 SF GROSSTOTAL: 2,494 SF GROSSRESIDENTIAL AREA = 47.2% GROSS AREA OF BUILDINGBALCONY = 165 SFROOF TERRACE = 558 SFGENERAL NOTES1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND JOB SITE CONDITIONS BEFORE COMMENCING WORK AND SHALL REPORT ANY DISCREPANCIES TO THE ARCHITECT.2. GENERAL CONTRACTOR TO COORDINATE ARCHITECTURAL DRAWINGS WITH MECHANICAL, ELECTRICAL, AND PLUMBING.APPLICABLE CODES:2018 INTERNATIONAL BUILDING CODE 2018 UNIFORM PLUMBING CODE 2018 INTERNATIONAL MECHANICAL CODE 2017 NATIONAL ELECTRIC CODE 2018 INTERNATIONAL FUEL GAS CODE2018 INTERNATIONAL ENERGY CONSERVATION CODEDESIGN CRITERIASEISMIC ZONE D0PLAN NOTES1. CONTRACTOR TO CONFIRM SIZE & TYPE OF WATER HEATER, SET HEATER IN 1 1/2" DEEP 24 GA. GALVANIZED STEEL PAN DRAINED w/ 3/4" INDIRECT WASTE PIPE. WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO PREVENT HORIZONTAL MOVEMENT2. ELEVATE WATER HEATER 18" MINIMUM ABOVE GARAGE SLAB TO ANY ELEMENT OR SWITCH THAT MAY SPARK3. A PERMANENT CRAWL SPACE LADDER OR ATTIC SPACE PULL DOWN LADDER IS TO BE INSTALLED TO ACCESS THE HEATING UNIT OR BOILER. 4. THE MAXIMUM CLEAR TRAVEL PATH FROM THE CRAWL SPACE OR ATTIC ACCESS OPENING TO THE HEATING UNIT OR BOILER IS 20 FEET.5. PROVIDE LIGHT FIXTURE CONTROLLED BY A SWITCH LOCATED AT THE CRAWL SPACE ACCESS HATCH & A RECEPTACLE OUTLET SHALL BE INSTALLED AT OR NEAR THE FURNACE.MECHANICALEGRESS WINDOWSSAFETY GLAZING REQUIREMENTS1. TEMPER GLAZING AT LOCATIONS SPECIFED IN IBC 2018 2406.4FIRE RESISTANT CONSTRUCTION REQUIREMENTS1. DOOR(S) BETWEEN GARAGE & HOUSE SHALL BE 20-MINUTE & EQUIPPED WITH A SELF-CLOSING DEVICE.2. INSTALL 1/2" GWB @ WALLS & UNDER-STAIR SURFACE IN ENCLOSED ACCESSIBLE SPACE UNDER STAIRS 3. 1/2" GWB SHALL BE INSTALLED ON ALL WALLS SEPARATING THE GARAGE FROM THE DWELLING .4. WHERE HABITABLE ROOMS ARE ABOVE A GARAGE, APPLY 5/8" TYPE 'X' GWB ON GARAGE CEILING & 1/2" GWB ON WALLS SUPPORTING FLOOR ABOVE5. FOAM INSULATION SHALL BE SEPARATED FROM THE INTERIOR OF A BUILDING BY AN APPROVEDTHERMAL BARRIER OF MINIMUM 1/2 INCH GWB OR A MATERIAL THAT IS TESTED IN ACCORDANCE NFPA 275.6. PROVIDE FIRE BLOCKING VERTICALLY AT THE CEILING AND FLOOR LEVELS & HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FT.ALL SLEEPING ROOMS SHALL HAVE A MEANS OF EGRESS DIRECTLY TO THE OUTSIDE VIA A DOOR OR WINDOW. EGRESS WINDOWS SHALL MEET THE REQUIREMENTS OF IBC 2018 SECTION 1003 & 1005ENERGY REQUIREMENTS2018 INTERNATIONAL ENERGY CONSERVATION CODEMONTANA CLIMATE ZONE 6BINSULATION & FENESTRATION REQUIRMENTS BY COMPONENTCEILING FLAT: FLAT R-49VAULTED R-38WALLS: ABOVE GRADE R-21BASEMENTS R-19 CAVITY/ R-15 CONT.CRAWL SPACE R-19 CAVITY/ R-15 CONT.FLOORS: OVER UNHEATED SPACES R-30PERIMETER SLAB FOR 4 FT. R-10EXTERIOR DOORS R-3WINDOWS NFRC UNIT RATING U-0.32WATER HEATER ENERGY FACTOR RATING 0.58HEATING SYSTEM ENERGY EFFICIENCY RATING 78%(AFUE FOR GAS; HSPF HEAT PUMP)2-HR COMMON WALLTYPICAL 2-HR COMMON WALL ASSEMBLY(INSTALL BETWEEN SHOPS & BETWEEN RESIDENTIAL UNITS)UL/GA DESIGN = WP 3820, STC 58 (TEST NO: NGC 3056)• (2) LAYERS 5/8" FIRE-SHIELD GWB APPLIED TO EACH SIDE OF COMMON WALL. (INSTALL HORIZONTALLY OR VERTICALLY)• (2) 2X6 WOOD STUD WALLS ON SEPARATE 2X6 PLATES SPACED 2" APART, 2X6 STUDS SPACED AT 16" O.C.• 7/16" WOOD STRUCTURAL PANELS MAY BE INSTALLED ON THE INSIDES OF EACH STUD WALL IF REQUIRED STRUCTURALLY• 3 1/2" (MIN.) BATT INSULATION INSTALLED IN EACH STUD WALL TO ACHIEVE STC RATINGTYPICAL 2-HR FOYER/STAIR WALL ASSEMBLY(INSTALL BETWEEN SHOP AND FOYER/STAIR IN EA. UNIT)UL/GA DESIGN = U301• (2) LAYERS 5/8" USG FIRECODE CORE GWB APPLIED TO EACH SIDE OF WALL. (INSTALL HORIZONTALLY OR VERTICALLY)• 2X6 WOOD STUD WALL, 2X6 STUDS SPACED AT 16" O.C.2-HR FLOOR/CLG ASSEMBLY2-HR FLOOR CEILING ASSEMBLY B/W SHOP & RESIDENTIAL UNIT ABOVEUL DESIGN = L535• FINISH FLOORING• 5/8” PLYWOOD SUBFLOOR APPLIED AT RIGHT ANGLE TO WOOD TRUSSES• WOOD FLOOR TRUSSES• 3 ½” BATT INSULATION STAPLED UNDER SUBFLOORING AT 12” O.C.• (1) LAYER 5/8” USG FIRECODE C GYPSUM PANELS (OR EQUAL) APPLIED AT RIGHT ANGLES TO WOOD TRUSSES• RC-1 CHANNEL OR EQUIVALENT• (2) LAYERS 5/8” USG FIRECODE C GYPSUM PANELS (OR EQUAL) APPLIED AT RIGHT ANGLES TO RESILIENT CHANNEL(406) 552-4490www.blackmountainarch.comBLACK MOUNTAIN ARCHITECTURE 2020A2.3TERRACEFLOOR PLANSWISS PLAZA DUPLEXBUILDING XXXXX N. 27th AVENUE, BOZEMAN, MONTANAPERMIT SETJULY 13, 2022200241/4" = 1'-0"1TERRACE LEVEL