HomeMy WebLinkAbout027-PH1.1 - Photometric Lighting Plan_03182022S2-LC R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 S1 S1 S1 S2-RC W-13'-0"15'-0"POLE7'-0"DEPTH OF EMBEDFINISHED GRADE FINISHED GRADE HANDHOLE - 2 1/2" X 5" TWIN CONDUCTOR AS SHOWN ON PLANS, PROVIDE 1' OF COILED SLACK ON CONDUCTOR FEED THRU 1" CHAMFER BASE COVER 1'-8" SQUARE BUSH CONDUITS 2'-6"MIN.(4) #7 BARS @ CORNERS #3 BARS @ 12" O.C., VERT. REINFORCED CONC. BASE BY ELECTRICAL CONTRACTOR NOTE: CONTRACTOR SHALL GRIND EXPOSED CONCRETE SMOOTH. CONDUIT, PER SITE PLAN CONNECT GROUND TO POLE BASE W/ BOUNDRY #GB4C PROJECT ANCHOR BOLTS 3" MIN. ABOVE TOP OF BASE. PROVIDE DOUBLE NUTS FOR LEVELING UNIT (ONE ABV. AND ONE BLW. BASE FLANGE). PROVIDE NON-SHRINK GROUT IN VOID BETWEEN BASE FLANGE AND TOP OF CONC, LEAVING DRAIN HOLE. HAND FINISH. ANCHOR BOLTS FROM POLE MFR. FINISH GRADE. COMPACT SOIL IN 6" MAX. LEFTS IN EXCAVATED AREA AROUND POLE FOUND. LAMPS MOUNTING / VOLTAGECATALOG NO.MFR.TYPE LUMINAIRE SCHEDULE WALL MOUNT LED LITHONIAW-1 S-1 R1 LEDAREA LIGHT RECESSED CAN LED WALL / 10W RECESSED DOWNLIGHT / 6WLDN6 30K 05 L06 AR LD MVOLT DESCRIPTION LITHONIA LITHONIA WALL MOUNT W/ FORWARD THROW OPTIC RECESSED CAN - 6" ROUND WDGE2-P1-30K-90CRI-VCF POLE - FIXTURE AT 18' ABOVE GRADE SYMBOL S-2LC S-2RC AREA LIGHT AREA LIGHT LED LED AREA - TYPE V WIDE AREA - LEFT CORNER CUTOFF AREA - RIGHT CORNER CUTOFF LITHONIA LITHONIA DSX0 LED P1 30K T5W MVOLT HS POLE - FIXTURE AT 18' ABOVE GRADE POLE - FIXTURE AT 18' ABOVE GRADE DSX0 LED P1 30K LCCO MVOLT DSX0 LED P1 30K RCCO MVOLT UNITS AVG./MIN.MAX.TYPE PHOTOMETRIC CALCULATIONS ILLUMINANCE FOOTCANDLES AVG.LABEL 0.8 MIN. 3.7 0.2 4.0PARKING LOT SITE ILLUMINANCE FOOTCANDLES N/A 18.5 N/A MAX./MIN. Notes: 0.5 3.7 0.0 3805 valley commons drive suite #11 bozeman, mt 59718 406.556.6676 p 406.556.5782 f www.legendsstudio.com Reproduction of this sheet and/or re-use of this design without the express written consent of Legends Studio, Inc. violates the copyright laws of the United States and will be subject to legal prosecution. Copyright c 2022 Legends Studio, Inc. Verify scale noted on drawings, as size reduction will affect scale of drawings. DATE 3-18-22 PROJECT NO. TITLE SHEET REVISIONS ISSUED FOR SITE PLAN APPLICATION NELSON MEADOWS LOFTS BUILDINGS 1 & 2 LOT 17 NELSON MEADOWS SUBDIVISION BOZEMAN, MT KIRA E. OGLE 16002 BOZEMAN, MT PHOTOMETRIC SITE LIGHTING PLAN PH1.1 SCALE: 1 PH1.1 PHOTOMETRIC SITE LIGHTING PLAN 1"=20'-0"SCALE: 2 PH1.1 POLE FIXTURE DETAIL 3/4"=1'-0"