Loading...
HomeMy WebLinkAbout004-C1.2_UtilitiesPlanHYDUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPFOFOFOFOFOFOFOFOGASGASGASGASGASGASGASUGPUGPUGPUGPUGPUGPUGPUGPUGPFOFOFOGASGASGASSEWSEWSEWSEWSEWSEWSEWSEWSEWSEWSEWSEWSEWSEWSEWSEWSEWWATWATWATWATWATWATWATWATWATWATWATWATWATWATWATWATWATWATWATWAT WATSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTDDSSS56° 08' 10"E100.33'N88° 42' 50"E191.24'N6° 41' 29"W76.50'L=139.1834,R=170.0000D=46.9096N53° 35' 57"W75.17'S3 6 ° 2 4 ' 0 3 " W 23 1 . 0 8 'HYD8''W 8''W 8''W 8''W 8'' W 8'' W 8''W8''W8''W8''W8''S8''S8''S8''S8''S8''S8''S8''SSS0'20'40'60'C1.2AS NOTED UTILITIES PLANCKHEC Dec 02, 2022 - 10:39amCAD FILE: M:\213624\Drawings\Site Plan Submittal\1 - SITE PLAN.dwg REVISIONSDATEPROJECT NUMBERHYALITE Engineers, PLLC2304 N 7th Ave. Ste. LBozeman, MT 59715Tel: (406) 587.2781w w w . hyaliteeng. comFax: (406) 522.92252018LOT 17 ROYAL WOLF WAY BOZEMAN, MT11/02/202221362422x34 originals SCALESHEET TITLEDESIGN BYP R E L I M I N A R YMONTANABRETT C.No. 29106 PEMEGAARDPEFORSOILNASRENI G ENE PROPERTY LINEPROPOSED UTILITY EASEMENTEXISTING BURIED GAS LINEEXISTING OVERHEAD POWEREXISTING UNDERGROUND FIBEREXISTING 8" SEWER MAINEXISTING SEWER SERVICE LINEPROPOSED 6" SCH 40 PVC SEWER SERVICEEXISTING 8" DUCTILE IRON WATER MAINPROPOSED 1.5" COPPER WATER SERVICEEXISTING STORM WATER MAINPROPOSED STORM PIPEPROPOSED STORM RETENTIONEXISTING SIDEWALKPROPOSED SIDEWALK/WALKWAYPROPOSED ASPHALTFINISHED GROUND ELEVATIONEXISTING HYDRANTEXISTING STORM DRAIN MANHOLEEXISTING SANITARY SEWER MANHOLEEXISTING RECTANGULAR STORM DRAIN INLETEXISTING VALVEEXISTING POWER POLEMASTER LINE & SYMBOL LEGENDGAS1000OHPFO8''SSEWWATSHYDSTSEWER SERVICECLEANOUTPROPOSED 8" SEWERMAINPROPOSED 8" WATER MAINPROPOSEDBUILDINGPROPOSEDBUILDINGROYAL WOLF ROADVISION TRIANGLE (TYP.)PROPOSED CURB CUTAND SIDEWALK CHASEPROPOSED 70'X60'X45'STORM RETENTION PONDFOR STORMWATER BASIN 3PROPOSED 30'X15' STORMRETENTION POND FORSTORMWATER BASIN 1PROPOSED 60'X12' STORMRETENTION POND FORSTORMWATER BASIN 2EXISTING WATER LINES ARENOT BEING USED BY THEPROPOSED BUILDINGS ANDWILL BE CUT AND CAPPED ATTHE WATER MAINEXISTING SEWER LINE IS NOTBEING USED BY THEPROPOSED BUILDINGS ANDWILL BE CUT AND CAPPED ATTHE SEWER MAINSEWER SERVICECLEANOUTPROPOSED SEWERMANHOLESPROPOSED SEWERMANHOLESPROPOSED FIRE HYDRANTPROPOSED 4" FIRE LINEPROPOSED 4" FIRE LINEPROPOSED GAS AND POWERPER THE ARCHITECTPROPOSED 1.5" WATER LINEPROPOSED 1.5" WATER LINEPROPOSED 6" SEWER SERVICEPROPOSED 6" SEWER SERVICE106/07/2022TAP INTO EXISTINGWATER MAIN111CORE INTO EXISTING MANHOLEMATCH EXISTING INVERT ELEVATION1140.00' UTILITY EASEMENT1208/02/2022PROPOSED CURB STOP (TYP.)NOTE:-CORROSION PROTECTION SHALL BE PROVIDED FOR THEDUCTILE IRON WATER MAINS. V-BIO ENHANCEDPOLYETHYLENE ENCASEMENT OF THE MAIN WILL BEREQUIRED.230.0' SEWER AND WATER ESMT210.0' UTILITY ESMT2311/30/20223PROPOSED GATEVALVE (TYP.)3