HomeMy WebLinkAboutREScheck 18-PlexGenerated by REScheck-Web Software
Compliance Certificate
Project West Side Flats 18-Plex
Energy Code:2018 IECC
Location:Bozeman, Montana
Construction Type:Multi-family
Project Type:New Construction
Conditioned Floor Area:20,194 ft2
Glazing Area 18%
Climate Zone:6 (7836 HDD)
Permit Date:
Construction Site:Owner/Agent:Designer/Contractor:
Permit Number:
Compliance: Passes using UA trade-off
0.8% Better Than Code Maximum UA:5723 Your UA:5679
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Ceiling: Raised or Energy Truss 6,744 0.0 49.0 0.020 135
Side Wall: Wood Frame, 16" o.c.1,426 21.0 0.0 0.057 73
Side Window: Vinyl Frame 150 0.290 44
Side Wall: Wood Frame, 16" o.c.1,426 21.0 0.0 0.057 73
Side Window: Vinyl Frame 150 0.290 44
Front Wall: Wood Frame, 16" o.c.4,907 21.0 0.0 0.057 210
Door: Solid Door (under 50% glazing)360 0.200 72
Front Window: Vinyl Frame 864 0.290 251
Rear Wall: Wood Frame, 16" o.c.4,907 21.0 0.0 0.057 213
Door 1: Glass Door (over 50% glazing)360 0.290 104
Rear Window: Metal Frame w/ Thermal Break 810 0.290 235
Floor: Slab-On-Grade (Unheated)
Insulation depth: 4.0'
6,706 21.0 0.630 4225
Project Title: West Side Flats 18-Plex
Data filename:Page 1 of 2
05/14/21Report date:
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Title: West Side Flats 18-Plex
Data filename:Page 2 of 2
05/14/21Report date: