HomeMy WebLinkAboutREScheck 12-PlexGenerated by REScheck-Web Software
Compliance Certificate
Project West Side Flats 12-Plex
Energy Code:2018 IECC
Location:Bozeman, Montana
Construction Type:Multi-family
Project Type:New Construction
Conditioned Floor Area:13,488 ft2
Glazing Area 18%
Climate Zone:6 (7836 HDD)
Permit Date:
Construction Site:Owner/Agent:Designer/Contractor:
Permit Number:
Compliance: Passes using UA trade-off
0.5% Better Than Code Maximum UA:3884 Your UA:3865
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Ceiling: Raised or Energy Truss 4,508 0.0 49.0 0.020 90
Side Wall: Wood Frame, 16" o.c.1,426 21.0 0.0 0.057 73
Window 3: Vinyl Frame 150 0.290 44
Side Wall: Wood Frame, 16" o.c.1,426 21.0 0.0 0.057 73
Side Wall Windows: Vinyl Frame 150 0.290 44
Front Wall: Wood Frame, 16" o.c.3,271 21.0 0.0 0.057 140
Door: Solid Door (under 50% glazing)240 0.200 48
Front Wall Windows: Vinyl Frame 576 0.290 167
Rear Wall: Wood Frame, 16" o.c.3,271 21.0 0.0 0.057 142
Door 1: Glass Door (over 50% glazing)240 0.290 70
Rear Wall Windows: Vinyl Frame 540 0.290 157
Floor: Slab-On-Grade (Unheated)
Insulation depth: 4.0'
4,472 21.0 0.630 2817
Project Title: West Side Flats 12-Plex
Data filename:Page 1 of 2
05/14/21Report date:
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Title: West Side Flats 12-Plex
Data filename:Page 2 of 2
05/14/21Report date: