Loading...
HomeMy WebLinkAbout18-Plex Truss Drawings612 =2x4 =4x4 =4x4 =2x4 5 4 1 2 3 W1 T1 W3 B1 W2 1-0-0 -1-0-0 2-0-0 2-0-0 2-0-02-1-121-1-12 2-1-12Scale = 1:24.4 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 41.0 Plate Grip DOL 1.15 TC 0.15 Vert(LL)n/a -n/a 999 MT20 169/123 (Roof Snow = 41.0)Lumber DOL 1.15 BC 0.02 Vert(CT)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.08 Horz(CT)n/a -n/a n/a BCLL 0.0*Code IRC2018/TPI2014 Matrix-P BCDL 10.0 Weight: 11 lb FT = 20% LUMBER TOP CHORD 2x6 SPF-S No.2 BOT CHORD 2x4 DF No.1&Btr WEBS 2x4 SPF-S Std BRACING TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)4=58/ Mechanical, (min. 0-1-8), 5=278/0-5-8, (min. 0-1-8) Max Horiz 5=62 (LC 10) Max Uplift 4=-50 (LC 19), 5=-23 (LC 13) Max Grav 4=74 (LC 20), 5=382 (LC 20) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-5=-365/155 NOTES 1)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-16; Pf=41.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.103)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 41.0 psf on overhangs non-concurrent with other live loads. 5)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 6)Refer to girder(s) for truss to truss connections. 7)One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 5 and 4. This connection is for uplift only and does not consider lateral forces. 8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S)Standard Job Truss Truss Type Qty Ply WEST SIDE FLATS 18-PLEX A01 12 1WEST SIDE 18-PLEX Jack-Closed Job Reference (optional) Simkins Hallin Lumber Company, Bozeman,MT, jim Run: 8.43 S Jan 20 2021 Print: 8.430 S Jan 20 2021 MiTek Industries, Inc. Mon Jun 21 15:58:31 Page: 1 ID:5BDg?3FBBao0hfz05KduO5z5?J?-D3dvTw9?a5VJ_S9d4zmlZM_DxhWHi8amvPvwAPz4?Fs 812 =M18SHS 3x12 =7x8 =4x10 =4x6 =4x6 =4x6 =7x8 =4x4 =3x8 =6x6 =4x6 =4x10 =4x6 =2x4 =7x8 10117 16 24 15 14 25 13 12 26 11 27 9 2 2318 3 8 4 72219 5 20 21 6 T2 T1 T3 T4 T5 W1 B1 B3B2 W3 W4 W5 W6 W5 W7 W8 W2 HW2 3-0-0 -3-0-0 7-3-12 23-7-14 8-0-5 16-4-2 8-3-13 8-3-13 9-1-7 32-9-5 10-2-11 43-0-0 7-0-4 23-6-2 8-2-1 16-5-14 8-3-13 8-3-13 9-2-11 42-0-0 9-3-3 32-9-513-5-62-1-40-9-413-0-0Scale = 1:78.4 Plate Offsets (X, Y): [2:Edge,0-4-4], [5:0-5-4,0-3-8], [6:0-3-12,0-4-0], [16:0-2-4,0-2-0] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 41.0 Plate Grip DOL 1.15 TC 0.81 Vert(LL)-0.23 9-11 >999 240 MT20 169/123 (Roof Snow = 41.0)Lumber DOL 1.15 BC 0.85 Vert(CT)-0.38 9-11 >999 180 M18SHS 220/195 TCDL 10.0 Rep Stress Incr YES WB 0.77 Horz(CT)0.11 9 n/a n/a BCLL 0.0*Code IRC2018/TPI2014 Matrix-S BCDL 10.0 Weight: 240 lb FT = 20% LUMBER TOP CHORD 2x6 SPF-S No.2 *Except* T1,T5:2x6 DF 1800F 1.6E BOT CHORD 2x4 DF No.1&Btr WEBS 2x4 SPF-S Std *Except* W1,W2:2x4 DF No.1&Btr WEDGE Right: 2x6 SPF-S No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 2-8-10 oc purlins, except end verticals, and 2-0-0 oc purlins (3-7-10 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 16-17. WEBS 1 Row at midpt 4-14, 5-13 WEBS 2 Rows at 1/3 pts 8-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)9=2667/0-5-8, (min. 0-2-14), 17=2884/0-5-8, (min. 0-3-1) Max Horiz 17=-304 (LC 9) Max Uplift 9=-145 (LC 12), 17=-160 (LC 11) Max Grav 9=2713 (LC 23), 17=2884 (LC 1) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=0/334, 2-18=-3044/278, 3-18=-2992/293, 3-4=-2823/318, 4-19=-2641/348, 5-19=-2431/380, 5-20=-2102/391, 20-21=-2102/391, 6-21=-2102/391, 6-22=-2519/396, 7-22=-2610/365, 7-8=-2780/352, 8-23=-3654/355, 9-23=-3779/321, 2-17=-2808/397 BOT CHORD 16-17=-265/333, 16-24=-166/2529, 15-24=-166/2529, 14-15=-166/2529, 14-25=-56/2099, 13-25=-56/2099, 12-13=-189/2946, 12-26=-189/2946, 11-26=-189/2946, 11-27=-189/2946, 9-27=-189/2946 WEBS 4-16=-321/140, 4-14=-585/176, 5-14=-57/705, 5-13=-132/254, 6-13=-55/825, 8-13=-1182/229, 8-11=0/532, 2-16=-130/2329 NOTES 1)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) and C-C Exterior(2E) -3-1-8 to 1-0-14, Interior (1) 1-0-14 to 16-4-2, Exterior(2R) 16-4-2 to 22-3-6, Interior (1) 22-3-6 to 23-7-14, Exterior(2R) 23-7-14 to 29-7-2, Interior (1) 29-7-2 to 43-1-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-16; Pf=41.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 41.0 psf on overhangs non-concurrent with other live loads. 4)Provide adequate drainage to prevent water ponding. 5)All plates are MT20 plates unless otherwise indicated. 6)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf. 7)One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 17 and 9. This connection is for uplift only and does not consider lateral forces. 8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S)Standard Job Truss Truss Type Qty Ply WEST SIDE FLATS 18-PLEX B01 32 1WEST SIDE 18-PLEX Piggyback Base Job Reference (optional) Simkins Hallin Lumber Company, Bozeman,MT, jim Run: 8.43 S Jan 20 2021 Print: 8.430 S Jan 20 2021 MiTek Industries, Inc. Mon Jun 21 15:58:31 Page: 1 ID:mnNd0U4ru4nBFOxflJwRmrz5?N5-D3dvTw9?a5VJ_S9d4zmlZM_3dhJIizomvPvwAPz4?Fs 812 =M18SHS 3x12 =7x8 =4x10 =4x6 =4x6 =4x6 =7x8 =4x4 =3x8 =6x6 =4x6 =4x6 =4x6 =4x10 =7x8 =M18SHS 3x12 10118 17 25 16 15 26 14 13 27 12 11 921924 83 4 7 20 23 5 21 22 6 T2 T1 T3 T2 T1 W1 W1 B1 B1B2 W3 W4 W5 W6 W5 W4 W3 W2 W2 3-0-0 -3-0-0 3-0-0 43-0-0 7-3-12 23-7-14 8-0-5 16-4-2 8-0-5 31-8-3 8-3-13 8-3-13 8-3-13 40-0-0 7-0-4 23-6-2 8-2-1 16-5-14 8-2-1 31-8-3 8-3-13 40-0-0 8-3-13 8-3-1313-5-62-1-413-0-0Scale = 1:77 Plate Offsets (X, Y): [2:Edge,0-4-4], [5:0-5-4,0-3-8], [6:0-3-12,0-3-12], [9:Edge,0-4-4], [12:0-3-0,0-1-12], [17:0-3-0,0-1-12] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 41.0 Plate Grip DOL 1.15 TC 0.59 Vert(LL)-0.17 15-17 >999 240 MT20 169/123 (Roof Snow = 41.0)Lumber DOL 1.15 BC 0.60 Vert(CT)-0.28 15-17 >999 180 M18SHS 220/195 TCDL 10.0 Rep Stress Incr YES WB 0.50 Horz(CT)0.06 11 n/a n/a BCLL 0.0*Code IRC2018/TPI2014 Matrix-S BCDL 10.0 Weight: 246 lb FT = 20% LUMBER TOP CHORD 2x6 SPF-S No.2 *Except* T1:2x6 DF 1800F 1.6E BOT CHORD 2x4 DF No.1&Btr WEBS 2x4 SPF-S Std *Except* W1,W2:2x4 DF No.1&Btr BRACING TOP CHORD Structural wood sheathing directly applied or 3-6-1 oc purlins, except end verticals, and 2-0-0 oc purlins (3-10-7 max.): 5-6. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 4-15, 5-14, 7-14 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)11=2756/0-5-8, (min. 0-2-15), 18=2756/0-5-8, (min. 0-2-15) Max Horiz 18=-326 (LC 9) Max Uplift 11=-158 (LC 12), 18=-158 (LC 11) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=0/334, 2-19=-2870/247, 3-19=-2829/266, 3-4=-2583/291, 4-20=-2444/329, 5-20=-2226/359, 5-21=-1853/368, 21-22=-1853/368, 6-22=-1853/368, 6-23=-2221/359, 7-23=-2445/329, 7-8=-2636/291, 8-24=-2828/266, 9-24=-2870/247, 9-10=0/334, 2-18=-2680/383, 9-11=-2680/383 BOT CHORD 17-18=-263/354, 17-25=-136/2400, 16-25=-136/2400, 15-16=-136/2400, 15-26=-58/1950, 14-26=-58/1950, 13-14=-69/2212, 13-27=-69/2212, 12-27=-69/2212 WEBS 4-17=-290/158, 4-15=-611/177, 5-15=-55/726, 6-14=-37/682, 7-14=-610/177, 7-12=-291/159, 2-17=-112/2178, 9-12=-113/2172 NOTES 1)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) and C-C Exterior(2E) -3-1-8 to 0-10-8, Interior (1) 0-10-8 to 16-4-2, Exterior(2R) 16-4-2 to 22-0-0, Interior (1) 22-0-0 to 23-7-14, Exterior(2R) 23-7-14 to 29-3-12, Interior (1)29-3-12 to 43-1-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-16; Pf=41.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 41.0 psf on overhangs non-concurrent with other live loads. 4)Provide adequate drainage to prevent water ponding. 5)All plates are MT20 plates unless otherwise indicated. 6)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7)One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 18 and 11. This connection is for uplift only and does not consider lateral forces. 8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S)Standard Job Truss Truss Type Qty Ply WEST SIDE FLATS 18-PLEX B02 12 1WEST SIDE 18-PLEX Piggyback Base Job Reference (optional) Simkins Hallin Lumber Company, Bozeman,MT, jim Run: 8.43 S Jan 20 2021 Print: 8.430 S Jan 20 2021 MiTek Industries, Inc. Mon Jun 21 15:58:32 Page: 1 ID:bUokP9ZxTNqW2X_L5ieqOHz5?MT-hFAHgG9dLOdAbckpehI?5ZXHq4jRRVFv83eUirz4?Fr 812 =2x4 =6x6 =4x10 =4x6 =4x6 =4x6 =4x6 =4x6 =6x6 =3x8 =7x8 =4x4 =4x6 =4x6 =4x4 =4x10 =7x8 =M18SHS 3x12 11120 19 18 2717 16 28 15 14 29 13 12 1022126 3 4 9 8 522 25 6 23 24 7 T2 T1 T3 T4 T5 W1 W1 B1 B1B2 W7 W8 W7 W9 W10 W11 W3 W2 W6W5 W4 3-0-0 -3-0-0 3-0-0 43-0-0 4-2-12 4-2-12 6-0-11 10-3-7 7-3-12 23-7-14 6-0-11 16-4-2 8-0-5 31-8-3 8-3-13 40-0-0 4-2-12 4-2-12 6-0-11 10-3-7 6-2-7 16-5-14 7-0-4 23-6-2 8-2-1 31-8-3 8-3-13 40-0-013-5-62-1-413-0-0Scale = 1:77 Plate Offsets (X, Y): [2:Edge,0-3-12], [4:0-2-12,0-2-0], [6:0-3-12,0-3-4], [7:0-5-4,0-3-8], [10:Edge,0-4-4], [13:0-1-12,0-1-8] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 41.0 Plate Grip DOL 1.15 TC 0.59 Vert(LL)-0.15 13-15 >999 240 MT20 169/123 (Roof Snow = 41.0)Lumber DOL 1.15 BC 0.56 Vert(CT)-0.24 13-15 >999 180 M18SHS 220/195 TCDL 10.0 Rep Stress Incr YES WB 0.56 Horz(CT)0.05 12 n/a n/a BCLL 0.0*Code IRC2018/TPI2014 Matrix-S BCDL 10.0 Weight: 253 lb FT = 20% LUMBER TOP CHORD 2x6 SPF-S No.2 *Except* T1,T5:2x6 DF 1800F 1.6E BOT CHORD 2x4 DF No.1&Btr WEBS 2x4 SPF-S Std *Except* W1,W11,W4:2x4 DF No.1&Btr BRACING TOP CHORD Structural wood sheathing directly applied or 3-11-8 oc purlins, except end verticals, and 2-0-0 oc purlins (4-4-9 max.): 6-7. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 7-16, 8-15, 4-19, 5-18 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)12=2517/0-5-8, (min. 0-2-11), 19=2326/0-5-8, (min. 0-2-10), 20=669/0-5-8, (min. 0-1-8) Max Horiz 20=326 (LC 10) Max Uplift 12=-155 (LC 12), 19=-148 (LC 11), 20=-79 (LC 7) Max Grav 12=2517 (LC 1), 19=2470 (LC 22), 20=783 (LC 17) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=0/334, 4-5=-1715/243, 5-22=-1841/305, 6-22=-1819/337, 6-23=-1393/325, 23-24=-1393/325, 7-24=-1393/325, 7-25=-1850/326, 8-25=-2074/294, 8-9=-2238/270, 9-26=-2512/245, 10-26=-2545/226, 10-11=0/334, 2-20=-762/232, 10-12=-2441/361 BOT CHORD 19-20=-307/284, 18-27=-102/1416, 17-27=-102/1416, 16-17=-102/1416, 16-28=0/1575, 15-28=0/1575, 14-15=-51/1942, 14-29=-51/1942, 13-29=-51/1942 WEBS 6-16=-48/461, 7-16=-392/102, 7-15=-54/766, 8-15=-658/177, 10-13=-88/1900, 4-19=-2241/227, 5-18=-834/118, 4-18=-110/1623 NOTES 1)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) and C-C Exterior(2E) -3-1-8 to 0-10-8, Interior (1) 0-10-8 to 16-4-2, Exterior(2R) 16-4-2 to 22-0-0, Interior (1) 22-0-0 to 23-7-14, Exterior(2R) 23-7-14 to 29-3-12, Interior (1)29-3-12 to 43-1-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-16; Pf=41.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 41.0 psf on overhangs non-concurrent with other live loads. 4)Provide adequate drainage to prevent water ponding. 5)All plates are MT20 plates unless otherwise indicated. 6)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord andany other members, with BCDL = 10.0psf. 7)One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 20, 12, and 19. This connection is for uplift only and does not consider lateral forces. 8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S)Standard Job Truss Truss Type Qty Ply WEST SIDE FLATS 18-PLEX B03 30 1WEST SIDE 18-PLEX Piggyback Base Job Reference (optional) Simkins Hallin Lumber Company, Bozeman,MT, jim Run: 8.43 S Jan 20 2021 Print: 8.430 S Jan 20 2021 MiTek Industries, Inc. Mon Jun 21 15:58:32 Page: 1 ID:NkY1m0jbY3FFPubZW5rZcqz5?Jh-hFAHgG9dLOdAbckpehI?5ZXHq4k3RUJv83eUirz4?Fr 812 =M18SHS 3x12=4x4 =3x8 =4x4 =4x10 =4x10 =4x10 =4x10 =4x10 =4x10 =4x6 28151 50 49 48 47 46 45 44 43 42 41 52 40 53 39 54 38 55 37 36 35 34 33 32 31 30 29 27 2 263 254524 236 227 218 9 20 10 19 11 18 1213 14 15 1617 W1 T2 T1 T3 T2 T1 B1 B3B2 ST9ST9ST9ST8 ST7 ST6 ST5 ST4 ST3 ST2 ST1 ST9 ST8 ST7 ST6 ST5 ST4 ST3 ST2 ST1 3-0-0 -3-0-0 7-3-12 23-7-14 16-4-2 16-4-2 19-4-2 43-0-0 42-0-013-5-62-1-40-9-413-0-0Scale = 1:78.4 Plate Offsets (X, Y): [5:0-2-13,Edge], [12:0-5-0,0-0-0], [17:0-5-0,0-0-0], [24:0-2-13,Edge], [50:0-4-12,0-1-8] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 41.0 Plate Grip DOL 1.15 TC 0.74 Vert(LL)-0.16 39-40 >764 240 M18SHS 169/123 (Roof Snow = 41.0)Lumber DOL 1.15 BC 0.62 Vert(CT)-0.22 39-40 >545 180 MT20 169/123 TCDL 10.0 Rep Stress Incr YES WB 0.61 Horz(CT)0.01 27 n/a n/a BCLL 0.0*Code IRC2018/TPI2014 Matrix-S BCDL 10.0 Weight: 307 lb FT = 20% LUMBER TOP CHORD 2x6 SPF-S No.2 *Except* T1:2x6 DF 1800F 1.6E BOT CHORD 2x6 SPF-S No.2 WEBS 2x4 SPF-S Std OTHERS 2x4 SPF-S Std BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 12-17. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 15-39, 14-40, 13-41, 11-43, 10-44, 9-45, 16-38, 18-37, 19-35, 20-34 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 16-3-8. except 27=17-2-8, 37=17-2-8, 35=17-2-8, 34=17-2-8, 33=17-2-8, 32=17-2-8, 31=17-2-8, 30=17-2-8, 29=17-2-8 (lb) -Max Horiz 51=-303 (LC 9) Max Uplift All uplift 100 (lb) or less at joint(s) 29, 30, 31, 32, 33, 34, 45, 46, 47, 48, 49 except 27=-144 (LC 8), 35=-400 (LC 21), 37=-245 (LC 7), 43=-139 (LC 7), 44=-423 (LC 21), 50=-839 (LC 17), 51=-215 (LC 7) Max Grav All reactions 250 (lb) or less at joint(s) 30, 31, 33, 35, 44, 46, 49, 50 except 27=416 (LC 19), 29=319 (LC 20), 32=253 (LC 1), 34=363 (LC 1), 37=1364 (LC 1), 43=1317 (LC 1), 45=363 (LC 1), 47=254 (LC 1), 48=253 (LC 1), 51=1598 (LC 17) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-51=-1553/498, 1-2=0/334, 2-3=-551/210, 3-4=-264/105, 7-8=-234/277, 8-9=-269/339, 9-10=-304/403, 10-11=-310/470, 11-12=-371/462, 12-13=-308/442, 13-14=-308/442, 14-15=-308/442, 15-16=-308/442, 16-17=-308/442, 17-18=-371/462, 18-19=-311/470, 19-20=-304/403, 20-21=-311/339, 21-22=-318/277, 22-23=-328/259, 23-24=-330/260, 24-25=-337/249, 25-26=-354/261, 26-27=-403/280 BOT CHORD 50-51=-210/274, 49-50=-210/274, 48-49=-210/274, 47-48=-210/274, 46-47=-210/274, 45-46=-210/274, 44-45=-210/274, 43-44=-210/274, 42-43=-210/274, 41-42=-210/274, 41-52=-210/274, 40-52=-210/274, 40-53=-210/274, 39-53=-210/274, 39-54=-210/274, 38-54=-210/274, 38-55=-210/274, 37-55=-210/274, 36-37=-210/274, 35-36=-210/274, 34-35=-210/274, 33-34=-210/274, 32-33=-210/274, 31-32=-210/274, 30-31=-210/274, 29-30=-210/274, 27-29=-210/274 WEBS 11-43=-520/24, 3-50=-211/826, 18-37=-519/83, 26-29=-253/129 NOTES 1)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) and C-C Corner(3E) -3-1-8 to 1-0-0, Exterior(2N) 1-0-0 to 16-4-2, Corner(3R) 16-4-2 to 20-6-8, Exterior(2N) 20-6-8 to 23-7-14,Corner(3R) 23-7-14 to 27-10-4, Exterior(2N) 27-10-4 to 43-1-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3)TCLL: ASCE 7-16; Pf=41.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 41.0 psf on overhangs non-concurrent with other live loads. 5)Provide adequate drainage to prevent water ponding. 6)All plates are MT20 plates unless otherwise indicated. 7)All plates are 2x4 MT20 unless otherwise indicated. 8)Gable studs spaced at 2-0-0 oc. Job Truss Truss Type Qty Ply WEST SIDE FLATS 18-PLEX B04 2 1WEST SIDE 18-PLEX Piggyback Base Supported Gable Job Reference (optional) Simkins Hallin Lumber Company, Bozeman,MT, jim Run: 8.43 S Jan 20 2021 Print: 8.430 S Jan 20 2021 MiTek Industries, Inc. Mon Jun 21 15:58:32 Page: 1 ID:Vmuod5H3UVAbY6hbmTBb0kz5?Iy-hFAHgG9dLOdAbckpehI?5ZXFT4j7RTXv83eUirz4?Fr Continued on page 2 9)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 10)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 45, 46,47, 48, 49, 34, 33, 32, 31, 30, 29 except (jt=lb) 51=215, 27=144, 43=138, 44=422, 50=838, 37=245, 35=400. 11)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13)"NAILED" indicates 3-10d (0.148"x3") or 3-12d (0.148"x3.25") toe-nails per NDS guidlines. LOAD CASE(S)Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-2=-102, 2-12=-102, 12-17=-102, 17-28=-102, 27-51=-20 Concentrated Loads (lb) Vert: 42=-54, 37=-54, 52=-54, 53=-54, 54=-54, 55=-54 Job Truss Truss Type Qty Ply WEST SIDE FLATS 18-PLEX B04 2 1WEST SIDE 18-PLEX Piggyback Base Supported Gable Job Reference (optional) Simkins Hallin Lumber Company, Bozeman,MT, jim Run: 8.43 S Jan 20 2021 Print: 8.430 S Jan 20 2021 MiTek Industries, Inc. Mon Jun 21 15:58:32 Page: 2 ID:Vmuod5H3UVAbY6hbmTBb0kz5?Iy-hFAHgG9dLOdAbckpehI?5ZXFT4j7RTXv83eUirz4?Fr 812 =4x6 =4x4 =4x10 =6x6 =4x10 =4x10 =6x6 =4x10 =4x6 =4x4 1 2748 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 262 3 25 4 24235 226 217 8 20 199 10 18 11 171213141516 W1 T2 T1 T3 T2 T1 W1 B1 B1B2 ST9ST9ST8 ST7 ST6 ST5 ST4 ST3 ST2 ST1 ST9 ST8 ST7 ST6 ST5 ST4 ST3 ST2 ST1 3-0-0 -3-0-0 3-0-0 43-0-0 7-3-12 23-7-14 16-4-2 16-4-2 16-4-2 40-0-0 40-0-013-5-62-1-413-0-0Scale = 1:77 Plate Offsets (X, Y): [2:0-2-0,0-1-12], [12:0-5-0,0-0-0], [16:0-5-0,0-0-0], [26:0-2-0,0-1-12], [28:Edge,0-3-8] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 41.0 Plate Grip DOL 1.15 TC 0.59 Vert(LL)-0.04 39-40 >999 240 MT20 169/123 (Roof Snow = 41.0)Lumber DOL 1.15 BC 0.19 Vert(CT)-0.05 39-40 >999 180 TCDL 10.0 Rep Stress Incr YES WB 0.46 Horz(CT)0.01 28 n/a n/a BCLL 0.0*Code IRC2018/TPI2014 Matrix-R BCDL 10.0 Weight: 300 lb FT = 20% LUMBER TOP CHORD 2x6 SPF-S No.2 *Except* T1:2x6 DF 1800F 1.6E BOT CHORD 2x4 DF No.1&Btr WEBS 2x4 SPF-S Std OTHERS 2x4 SPF-S Std BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 12-16. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 14-38, 13-39, 11-40, 10-41, 9-42, 8-43, 15-37, 17-36, 18-35, 19-34, 20-33 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 20-9-8. except 48=15-2-8, 41=15-2-8, 42=15-2-8, 43=15-2-8, 44=15-2-8, 45=15-2-8, 46=15-2-8, 47=15-2-8 (lb) -Max Horiz 48=-326 (LC 9) Max Uplift All uplift 100 (lb) or less at joint(s) 30, 31, 32, 33, 34, 35, 37, 38, 43, 44, 45, 46 except 28=-234 (LC 8), 29=-505 (LC 17), 42=-107 (LC 11), 47=-505 (LC 17), 48=-250 (LC 7) Max Grav All reactions 250 (lb) or less at joint(s) 29, 31, 32, 33, 34, 35, 37, 42, 44, 45, 47 except 28=1130 (LC 17), 30=277 (LC 1), 36=258 (LC 1), 38=630 (LC 1), 41=640 (LC 1), 43=264 (LC 1), 46=277 (LC 1), 48=1130 (LC 17) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-48=-1122/425, 1-2=0/334, 2-3=-282/222, 6-7=-128/276, 7-8=-163/337, 8-9=-198/400, 9-10=-230/485, 10-11=-281/483, 11-12=-236/433, 12-13=-236/467, 13-14=-236/467, 14-15=-236/467, 15-16=-236/467, 16-17=-228/426, 17-18=-269/519, 18-19=-238/467, 19-20=-199/399, 20-21=-163/337, 21-22=-128/276, 25-26=-270/209, 26-27=0/334, 26-28=-1122/424 WEBS 14-38=-410/33, 10-41=-406/16, 3-47=-131/556, 25-29=-125/556 NOTES 1)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) and C-C Corner(3E) -3-1-8 to 0-10-8, Exterior(2N) 0-10-8 to 16-4-2, Corner(3R) 16-4-2 to 20-4-2, Exterior(2N) 20-4-2 to 23-7-14, Corner(3R) 23-7-14 to 27-7-14, Exterior(2N) 27-7-14 to 43-1-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3)TCLL: ASCE 7-16; Pf=41.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 41.0 psf on overhangs non-concurrent with other live loads. 5)Provide adequate drainage to prevent water ponding. 6)All plates are 2x4 MT20 unless otherwise indicated. 7)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8)Gable studs spaced at 2-0-0 oc. 9)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 10)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 38, 43,44, 45, 46, 37, 35, 34, 33, 32, 31, 30 except (jt=lb) 48=249, 28=234, 42=107, 47=505, 29=505. 11)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. Job Truss Truss Type Qty Ply WEST SIDE FLATS 18-PLEX B05 6 1WEST SIDE 18-PLEX Piggyback Base Supported Gable Job Reference (optional) Simkins Hallin Lumber Company, Bozeman,MT, jim Run: 8.43 S Jan 20 2021 Print: 8.430 S Jan 20 2021 MiTek Industries, Inc. Mon Jun 21 15:58:33 Page: 1 ID:GavFteblbBK22y6OkD7SW?z5?IZ-9SkftcAF6il1DmJ0COpEen3SaUA5Ay72MjO1EIz4?Fq Continued on page 2 12)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S)Standard Job Truss Truss Type Qty Ply WEST SIDE FLATS 18-PLEX B05 6 1WEST SIDE 18-PLEX Piggyback Base Supported Gable Job Reference (optional) Simkins Hallin Lumber Company, Bozeman,MT, jim Run: 8.43 S Jan 20 2021 Print: 8.430 S Jan 20 2021 MiTek Industries, Inc. Mon Jun 21 15:58:33 Page: 2 ID:GavFteblbBK22y6OkD7SW?z5?IZ-9SkftcAF6il1DmJ0COpEen3SaUA5Ay72MjO1EIz4?Fq 812 =4x6 =4x4 =4x6 =4x10 =4x6 =4x10 =4x10 =4x6 =4x10 =4x6 29153 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 28 27 2 263 254524 236 227 218 209 1910 1811 1213 14 15 1617 W1 T2 T1 T3 T2 T1 B1 B3B2 HW2 ST9ST9ST9ST8 ST7 ST6 ST5 ST4 ST3 ST2 ST1 ST9 ST8 ST7 ST6 ST5 ST4 ST3 ST2 ST1 ST10 3-0-0 -3-0-0 7-3-12 23-7-14 16-4-2 16-4-2 19-4-2 43-0-0 42-0-013-5-62-1-40-9-413-0-0Scale = 1:78.4 Plate Offsets (X, Y): [5:0-2-13,Edge], [12:0-5-0,0-0-0], [17:0-5-0,0-0-0], [24:0-2-13,Edge], [28:Edge,0-1-5] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 41.0 Plate Grip DOL 1.15 TC 0.59 Vert(LL)n/a -n/a 999 MT20 169/123 (Roof Snow = 41.0)Lumber DOL 1.15 BC 0.07 Vert(CT)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.57 Horz(CT)-0.01 28 n/a n/a BCLL 0.0*Code IRC2018/TPI2014 Matrix-S BCDL 10.0 Weight: 304 lb FT = 20% LUMBER TOP CHORD 2x6 SPF-S No.2 *Except* T1:2x6 DF 1800F 1.6E BOT CHORD 2x4 DF No.1&Btr WEBS 2x4 SPF-S Std OTHERS 2x4 SPF-S Std WEDGE Right: 2x4 SPF-S Std BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (10-0-0 max.): 12-17. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 15-41, 14-42, 13-43, 11-45, 10-46, 9-47, 16-40, 18-39, 19-37, 20-36 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 42-0-0. (lb) -Max Horiz 53=-305 (LC 9) Max Uplift All uplift 100 (lb) or less at joint(s) 30, 31, 32, 33, 34, 35, 36, 37, 39, 40, 41, 42, 46, 47, 48, 49, 50, 51 except 28=-214 (LC 8), 52=-724 (LC 17), 53=-130 (LC 7) Max Grav All reactions 250 (lb) or less at joint(s) 30, 32, 33, 34, 35, 36, 37, 39, 41, 42, 45, 46, 47, 48, 49, 51, 52 except 28=306 (LC 22), 31=256 (LC 1), 40=256 (LC 24), 43=252 (LC 1), 50=257 (LC 1), 53=1456 (LC 17) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-53=-1470/499, 1-2=0/334, 2-3=-439/217, 7-8=-171/286, 8-9=-206/347, 9-10=-244/412, 10-11=-284/481, 11-12=-281/473, 12-13=-258/449, 13-14=-258/449, 14-15=-258/449, 15-16=-258/449, 16-17=-258/449, 17-18=-281/473, 18-19=-284/481, 19-20=-244/412, 20-21=-206/347, 21-22=-208/286, 22-23=-221/256, 23-24=-232/257, 25-26=-247/259, 26-27=-262/276, 27-28=-309/324 WEBS 3-52=-206/775 NOTES 1)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) and C-C Corner(3E) -3-1-8 to 1-0-0, Exterior(2N) 1-0-0 to 16-4-2, Corner(3R) 16-4-2 to 20-6-8, Exterior(2N) 20-6-8 to 23-7-14,Corner(3R) 23-7-14 to 27-10-4, Exterior(2N) 27-10-4 to 43-1-8 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3)TCLL: ASCE 7-16; Pf=41.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 41.0 psf on overhangs non-concurrent with other live loads. 5)Provide adequate drainage to prevent water ponding. 6)All plates are 2x4 MT20 unless otherwise indicated. 7)Gable requires continuous bottom chord bearing. 8)Gable studs spaced at 2-0-0 oc. 9)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 10)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 41, 42,46, 47, 48, 49, 50, 51, 40, 39, 37, 36, 35, 34, 33, 32, 31, 30 except (jt=lb) 53=130, 28=213, 52=723. 11)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. Job Truss Truss Type Qty Ply WEST SIDE FLATS 18-PLEX B06 2 1WEST SIDE 18-PLEX Piggyback Base Supported Gable Job Reference (optional) Simkins Hallin Lumber Company, Bozeman,MT, jim Run: 8.43 S Jan 20 2021 Print: 8.430 S Jan 20 2021 MiTek Industries, Inc. Mon Jun 21 15:58:33 Page: 1 ID:2Owi7BuRisTUYoWCiz4J1Hz5?IA-9SkftcAF6il1DmJ0COpEen3SaUByAxQ2MjO1EIz4?Fq Continued on page 2 12)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S)Standard Job Truss Truss Type Qty Ply WEST SIDE FLATS 18-PLEX B06 2 1WEST SIDE 18-PLEX Piggyback Base Supported Gable Job Reference (optional) Simkins Hallin Lumber Company, Bozeman,MT, jim Run: 8.43 S Jan 20 2021 Print: 8.430 S Jan 20 2021 MiTek Industries, Inc. Mon Jun 21 15:58:33 Page: 2 ID:2Owi7BuRisTUYoWCiz4J1Hz5?IA-9SkftcAF6il1DmJ0COpEen3SaUByAxQ2MjO1EIz4?Fq 612THISENDOVER STORAGE ROOM BEARING POINT =4x10 =6x6 =6x6 =2x4 =4x4 =4x6 =4x4 =3x8 =6x6 =4x4 =4x6 =4x4 =2x4 =6x6 =6x6 =4x10 111 2 16 15 14 13 12 101722 93 84182157 19 20 6 T2 T1 T2 T1 B1 B1B2 W3 W4 W1W2W1 HW1 HW1 2-0-0 -2-0-0 2-0-0 34-0-0 7-10-4 16-0-0 7-10-4 23-10-4 8-1-12 8-1-12 8-1-12 32-0-0 7-3-8 15-5-4 8-1-12 8-1-12 8-1-12 32-0-0 8-5-0 23-10-49-6-21-1-129-1-12Scale = 1:61.5 Plate Offsets (X, Y): [2:0-7-10,Edge], [6:0-3-0,0-4-4], [10:0-7-10,Edge] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 41.0 Plate Grip DOL 1.15 TC 0.79 Vert(LL)-0.05 12 >999 240 MT20 169/123 (Roof Snow = 41.0)Lumber DOL 1.15 BC 0.28 Vert(CT)-0.11 2-16 >999 180 TCDL 10.0 Rep Stress Incr YES WB 0.83 Horz(CT)0.03 10 n/a n/a BCLL 0.0*Code IRC2018/TPI2014 Matrix-S BCDL 10.0 Weight: 166 lb FT = 20% LUMBER TOP CHORD 2x6 SPF-S No.2 BOT CHORD 2x4 DF No.1&Btr WEBS 2x4 SPF-S Std SLIDER Left 2x8 DF No.2 --4-7-8, Right 2x8 DF No.2 --4-7-8 BRACING TOP CHORD Structural wood sheathing directly applied or 5-8-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-14, 8-14, 4-14 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.REACTIONS (lb/size)2=1071/0-5-8, (min. 0-1-8), 10=1146/0-5-8, (min. 0-1-8), 14=2116/0-5-8, (min. 0-2-4) Max Horiz 2=-103 (LC 11) Max Uplift 2=-112 (LC 13), 10=-130 (LC 14), 14=-54 (LC 13) Max Grav 2=1123 (LC 20), 10=1205 (LC 21), 14=2116 (LC 1) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-17=-1146/147, 3-17=-996/162, 3-4=-772/183, 6-19=-14/460, 6-20=-25/399, 8-9=-933/195, 9-22=-1164/173, 10-22=-1308/159 BOT CHORD 2-16=-109/819, 15-16=-109/819, 14-15=-109/819, 13-14=-65/958, 12-13=-65/958, 10-12=-65/958 WEBS 6-14=-908/75, 8-14=-1259/214, 4-14=-1212/214 NOTES 1)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) and C-C Exterior(2E) -2-1-4 to 1-1-3, Interior (1) 1-1-3 to 16-0-0, Exterior(2R) 16-0-0 to 19-2-6, Interior (1) 19-2-6 to 34-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)TCLL: ASCE 7-16; Pf=41.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.103)Unbalanced snow loads have been considered for this design. 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 41.0 psf on overhangs non-concurrent with other live loads. 5)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 6)One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2, 14, and 10. This connection is for uplift only and does not consider lateral forces. 7)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S)Standard Job Truss Truss Type Qty Ply WEST SIDE FLATS 18-PLEX C01 18 1WEST SIDE 18-PLEX Common Job Reference (optional) Simkins Hallin Lumber Company, Bozeman,MT, jim Run: 8.43 S Jan 20 2021 Print: 8.430 S Jan 20 2021 MiTek Industries, Inc. Mon Jun 21 15:58:33 Page: 1 ID:i7O4lcuxrZG4r9dvs7Y?D4z5?Fb-9SkftcAF6il1DmJ0COpEen3PRU8gAtM2MjO1EIz4?Fq 612 THIS END OVER STORAGE ROOM BEARING POINT =3x8 =6x6 =6x6 =4x6 =4x4 =4x6 =4x6 =4x6 =3x8 =6x6 =4x6 =4x6 =4x6 =4x6 =4x4 =6x6 =6x6 =6x6 =3x8 191 2 31 30 29 28 27 2625 24 23 22 21 20 18 4338 32 35 33 36 1733437 4 165151463942137 1284140 119 10 T2 T1 T2 T1 B1 B1 W3 W4 W1W2W1 HW1 HW1 ST6 ST7 ST4 ST5 ST2 ST3ST1 ST8 ST9 ST10 ST11 ST12 ST13 ST1 2-0-0 -2-0-0 2-0-0 34-0-0 7-10-4 16-0-0 7-10-4 23-10-4 8-1-12 8-1-12 8-1-12 32-0-0 7-3-8 15-5-4 8-1-12 8-1-12 8-1-12 32-0-0 8-5-0 23-10-49-6-21-1-129-1-12Scale = 1:61.5 Plate Offsets (X, Y): [2:Edge,0-0-0], [15:0-3-0,Edge], [18:Edge,0-0-0], [25:0-2-12,Edge] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 41.0 Plate Grip DOL 1.15 TC 0.52 Vert(LL)-0.19 23 >999 240 MT20 169/123 (Roof Snow = 41.0)Lumber DOL 1.15 BC 0.55 Vert(CT)-0.23 23 >854 180 TCDL 10.0 Rep Stress Incr YES WB 0.87 Horz(CT)0.03 18 n/a n/a BCLL 0.0*Code IRC2018/TPI2014 Matrix-S BCDL 10.0 Weight: 209 lb FT = 20% LUMBER TOP CHORD 2x6 SPF-S No.2 BOT CHORD 2x4 DF No.1&Btr WEBS 2x4 SPF-S Std OTHERS 2x4 SPF-S Std SLIDER Left 2x8 DF No.2 --4-7-8, Right 2x8 DF No.2 --4-7-8 BRACING TOP CHORD Structural wood sheathing directly applied or 5-6-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 10-26 JOINTS 1 Brace at Jt(s): 33, 34, 35, 36, 37 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)2=1070/0-5-8, (min. 0-1-8), 18=1146/0-5-8, (min. 0-1-8), 26=2116/0-5-8, (min. 0-2-4) Max Horiz 2=-103 (LC 11) Max Uplift 2=-93 (LC 13), 18=-115 (LC 14), 26=-90 (LC 13) Max Grav 2=1127 (LC 20), 18=1226 (LC 21), 26=2116 (LC 1) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-38=-1145/100, 3-38=-980/115, 3-4=-901/126, 4-5=-833/164, 5-6=-745/168, 9-40=-20/296, 9-10=-37/288,10-11=-34/301, 14-15=-947/189, 15-16=-1025/184, 16-17=-1101/144, 17-43=-1197/130, 18-43=-1351/119 BOT CHORD 2-31=-75/806, 30-31=-75/806, 29-30=-75/806, 28-29=-75/806, 27-28=-75/806, 26-27=-75/806, 25-26=-35/985, 24-25=-35/985, 23-24=-35/985, 22-23=-35/985, 21-22=-35/985, 20-21=-35/985, 18-20=-35/985 WEBS 10-26=-723/8, 26-35=-1237/212, 35-36=-1239/213, 36-37=-1198/206, 14-37=-1243/215, 14-21=-47/295, 6-34=-1154/202, 33-34=-1117/194, 32-33=-1145/199, 26-32=-1171/202, 6-30=-46/285, 9-32=-358/68, 27-32=-312/63 NOTES 1)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) and C-C Exterior(2E) -2-1-4 to 1-1-3, Interior (1) 1-1-3 to 16-0-0, Exterior(2R) 16-0-0 to 19-2-6, Interior (1) 19-2-6 to 34-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3)TCLL: ASCE 7-16; Pf=41.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 41.0 psf on overhangs non-concurrent with other live loads. 6)All plates are 2x4 MT20 unless otherwise indicated. 7)Gable studs spaced at 2-0-0 oc. 8)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord andany other members. 9)One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2, 26, and 18. This connection is for uplift only and does not consider lateral forces. 10)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S)Standard Job Truss Truss Type Qty Ply WEST SIDE FLATS 18-PLEX C02 3 1WEST SIDE 18-PLEX Common Structural Gable Job Reference (optional) Simkins Hallin Lumber Company, Bozeman,MT, jim Run: 8.43 S Jan 20 2021 Print: 8.430 S Jan 20 2021 MiTek Industries, Inc. Mon Jun 21 15:58:34 Page: 1 ID:JepfOqgiYXSs885PAGCFMnz5?Ea-eeI15yBtt0turvuCm5KTA_ceSuQkuJ?CbN7ankz4?Fp 8 12 =4x4 =2x4 =4x4 =4x4 51 2 6 4 3 T1 T1 B1 ST1 1-0-3 1-0-3 1-0-3 7-3-0 2-7-5 6-2-13 2-7-5 3-7-8 5-2-112-5-40-6-14 0-1-8-0-1-82-3-122-3-12Scale = 1:20.5 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL 41.0 Plate Grip DOL 1.15 TC 0.08 Vert(LL)n/a -n/a 999 MT20 169/123 (Roof Snow = 41.0)Lumber DOL 1.15 BC 0.03 Vert(CT)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.03 Horz(CT)n/a -n/a n/a BCLL 0.0*Code IRC2018/TPI2014 Matrix-P BCDL 10.0 Weight: 22 lb FT = 20% LUMBER TOP CHORD 2x6 SPF-S No.2 BOT CHORD 2x4 DF No.1&Btr OTHERS 2x4 SPF-S Std BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.REACTIONS (lb/size)2=265/5-2-11, (min. 0-1-8), 4=265/5-2-11, (min. 0-1-8), 6=234/5-2-11, (min. 0-1-8) Max Horiz 2=-45 (LC 9) Max Uplift 2=-30 (LC 11), 4=-34 (LC 12) FORCES (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES 1)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.8psf; BCDL=4.2psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3)TCLL: ASCE 7-16; Pf=41.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 41.0 psf on overhangs non-concurrent with other live loads. 5)Gable requires continuous bottom chord bearing. 6)Gable studs spaced at 2-0-0 oc. 7)* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-06-00 tall by 2-00-00 wide will fit between the bottom chord and any other members. 8)One H2.5A Simpson Strong-Tie connectors recommended to connect truss to bearing walls due to UPLIFT at jt(s) 2 and 4. This connection is for uplift only and does not consider lateral forces. 9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10)See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S)Standard Job Truss Truss Type Qty Ply WEST SIDE FLATS 18-PLEX PB01 84 1WEST SIDE 18-PLEX Piggyback Job Reference (optional) Simkins Hallin Lumber Company, Bozeman,MT, jim Run: 8.43 S Jan 20 2021 Print: 8.430 S Jan 20 2021 MiTek Industries, Inc. Mon Jun 21 15:58:34 Page: 1 ID:LCiUNS2zb9PcOwC44ANk8Dz5?N8-eeI15yBtt0turvuCm5KTA_clIuYquW6CbN7ankz4?Fp