Loading...
HomeMy WebLinkAbout026.5 A2 FIRST AND SECOND FLOOR 18-PLEXDESCRIPTION:NO:DATE:DRAWN BY:CHECKED BY:JOB NO:PLOT SCALE:BY:2004-2022 JDS ARCHITECTSc01-06-22FALLON STREETSTAMPNo. 2557SOBREPENAJESSE D.ANATNOMFOE T ATS TANAMONEMANBOZENSELICARCDH I TECT BOZEMAN, MT WEST SIDE FLATS 18-PLEX PHASE 2 & 3A2 1/8"=1'-0"REFPATIOTYPE B UNITADAADAPTABLEWDSTORAGESTORAGEREFPATIOTYPE B UNITADAADAPTABLEWDREFPATIOTYPE A UNITWDSTORAGERISER ROOMREFPATIOTYPE B UNITWDUPADAADAPTABLEADAACCESSIBLEWHWHWHD.W.REFPATIOTYPE B UNITADAADAPTABLEWDSTORAGESTORAGEREFPATIOTYPE B UNITADAADAPTABLEWDUPWHWHUPD.W.D.W.D.W.D.W.D.W.WHREFWDSTORAGESTORAGEREFWDREFWDSTORAGESTORAGEREFWDUPDNDNREFWDSTORAGESTORAGEREFWDUPDNDNUPDNDNWHWHWHWHWHWHDECKDECKTYPE C UNITTYPE C UNITTYPE D UNITDECKDECKDECKDECKTYPE C UNITTYPE D UNITTYPE C UNITD.W.D.W.D.W.D.W.D.W.D.W.D.W.D.W.D.W.D.W.D.W.D.W.1/8"=1'-0"FIRST FLOOR PLAN 18-PLEXAA21/8"=1'-0"SECOND FLOOR PLAN 18-PLEXBA226'-0"12'-0"26'-0"26'-0"12'-0"26'-0"26'-0"12'-0"26'-0"42'-0"196'-0"14'-2"11'-10"26'-0"12'-0"14'-2"23'-8"14'-2"12'-0"14'-2"23'-8"14'-2"12'-0"14'-2"11'-10"52'-0"52'-0"26'-0"196'-0"16'-0"10'-0"12'-0"26'-0"26'-0"12'-0"26'-0"26'-0"16'-0"10'-0"12'-0"52'-0"12'-0"52'-0"12'-0"26'-0"AS3.1AS3.2AS3AS3.1AS3.2AS3W2W4W4W4W2W5W4W2W4W4W210'-0"16'-0"16'-0"10'-0"10'-0"16'-0"4'-0"16'-0"10'-0"10'-0"4'-0"4'-0"16'-0"10'-0"10'-0"16'-0"16'-0"10'-0"10'-0"16'-0"16'-0"10'-0"4'-0" 4'-0" 4'-0" 4'-0" 16'-9"9'-5"15'-10"W1W1W1W1W1W1W1W1W1W1W1W1W1W1W1W1W1W1W1W1W1W1W1W115'-8"20'-4"14'-2"14'-2"23'-8"14'-2"14'-2"23'-8"14'-2"42'-0"42'-0" 16'-9"9'-5"15'-10"14'-10"10'-3"13'-11"PROVIDE 1-HOUR WALL AT ALLSTORAGE UNITS COMMONWALLS. PROVIDE 5/8" TYPE X ONEA SIDE OF FRAMING, W/ MIN.FIRE TAPE FINISH4'-0"BS4.1BS4.1BS4.1BS4.1CRAWLSPACE, TYP.PROVIDE FIRE EXTINGUISHER ONEACH LANDING, MIN. SIZE2A:10BC, HUNG NO HIGHER THAN48" OFF FLOOR, TYP.42'-0"16'-11"9'-3"15'-10"11'-10"26'-0"192'-0"16'-0"26'-0"192'-0"TOTAL BUILDING AREA20,194 S.F.6,706 S.F.AREA 1ST FLOOR AREA TABULATIONS6,744 S.F.AREA 2ND FLOOR AREA 3RD FLOOR 6,744 S.F.1,118 S.F.UNIT TYPE "A"UNIT AREAS1,118 S.F.UNIT TYPE "B"UNIT TYPE "C"1,118 S.F.UNIT TYPE "D"1,136 S.F.NOTE:TOILETS MUST BE WATERSENSE LABELED (1.28GAL/FLUSH)SHOWERS MUST BE WATERSENSE LABELED (1.5 GPM)CLOTHES WASHERS MUST BE CEE TIER RATED(WATER FACTOR OF 4.0 OR LESS)PENETRATIONS OF FIRE-RESISTIVE WALLS,FLOOR-CEILINGS, AND ROOF-CEILINGS SHALL BEPROTECTED AS REQ'D IN IBC SECTION 714NOTE:THRESHOLDS IN ROLL-IN-TYPE SHOWERCOMPARTMENTS SHALL BE 1/2" MAX. IN HEIGHT INACCORDANCE WITH SECTION 303.STANDARDROLL-IN TYPESHOWERSEE NOTEFORTHRESHOLDSSEE E/S4.1W5W5W5W5W5W5W5W5W5W3W3W3W3PROVIDE 20MIN. RATEDDOORS AT ALLSTORAGE &FIRE RISER ROOMSPROVIDE 1-HOUR WALL AT ALLSTORAGE UNITS COMMONWALLS. PROVIDE 5/8" TYPE X ONEA SIDE OF FRAMING, W/ MIN.FIRE TAPE FINISHPROVIDE 3 1/2"SOFFIT AT ALLFLOORS FOR FIRE SPRINKLERSAND DUCTS, TYPELECTRIC WATERHEATER TYP.ELECTRIC WATER HEATER TYP.W5W5W5W5W5W5W5W3W3W3W3W3W3PROVIDE 20MIN. RATEDDOORS AT ALLSTORAGE &FIRE RISER ROOMSPROVIDE 1-HOUR WALL AT ALLSTORAGE UNITS COMMONWALLS. PROVIDE 5/8" TYPE X ONEA SIDE OF FRAMING, W/ MIN.FIRE TAPE FINISHPROVIDE 3 1/2"SOFFIT AT ALLFLOORS FOR FIRESPRINKLERSAND DUCTS, TYPAC UNIT, TYP.ELECTRIC WATER HEATER TYP.3'-0"14'-2"4'-0" 4'-0" 4'-0"PROVIDE 1-HOUR WALL AT ALL STORAGEUNITS COMMON WALLS. PROVIDE 5/8" TYPEX ON EA SIDE OF FRAMING, W/ MIN. FIRETAPE FINISHPROVIDE 1-HOUR WALL AT ALL STORAGE UNITSCOMMON WALLS. PROVIDE 5/8" TYPE X ON EA SIDEOF FRAMING, W/ MIN. FIRE TAPE FINISHPROVIDE 1-HOUR WALL AT ALL STORAGEUNITS COMMON WALLS. PROVIDE 5/8" TYPEX ON EA SIDE OF FRAMING, W/ MIN. FIRETAPE FINISHPROVIDE 1-HOUR WALL AT ALL STORAGE UNITSCOMMON WALLS. PROVIDE 5/8" TYPE X ON EA SIDEOF FRAMING, W/ MIN. FIRE TAPE FINISH4'-0"W3W3W3W3W3W5W5W5W3W3W357 SQ. FT.57 SQ. FT.57 SQ. FT.57 SQ. FT.57 SQ. FT.57 SQ. FT.80 SQ. FT.80 SQ. FT.80 SQ. FT.80 SQ. FT.80 SQ. FT.80 SQ. FT.19-073JDSRBT2'-0"2'-0"2'-0"2'-0"4'-4"4'-4" 4'-4" 4'-4" 4'-4" 4'-4"AWNING ABOVEAWNING ABOVEAWNING ABOVEAWNING BELOWAWNING BELOWAWNING BELOW2" WATER SERVICE4" FIRE RISER26'-0"12'-0"11'-10"AC UNIT, TYP.PROVIDE FIRE EXTINGUISHER ONEACH LANDING, MIN. SIZE2A:10BC, HUNG NO HIGHER THAN48" OFF FLOOR, TYP.PROVIDE FIREEXTINGUISHERON EACHLANDING MIN.SIZE 2A-10BC,HUNG NO HIGHERTHAN 48" OFFFLOOR TYP.PROVIDE FIRE EXTINGUISHER ON EACHLANDING MIN. SIZE 2A-10BC, HUNG NOHIGHER THAN 48" OFF FLOOR TYP.F.D.SIAMESECONNECTIONPROVIDE FIRE EXTINGUISHER ONEACH LANDING, MIN. SIZE2A:10BC, HUNG NO HIGHER THAN48" OFF FLOOR, TYP.PROVIDE FIRE EXTINGUISHER ONEACH LANDING, MIN. SIZE2A:10BC, HUNG NO HIGHER THAN48" OFF FLOOR, TYP.1 COB REVISIONS 03-09-22 AS