Loading...
HomeMy WebLinkAbout017_L3.2IrrigationDetailsFILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTION----IRRIGATION DETAILSWESTLAKE PARK IMPROVEMENTSWESTLAKE PARK, BLOCK 1, WESTLAKE'S FOURTH SUBDIVISIONBOZEMAN, MONTANAL3.2 EJS18098_18_LS DETAILS.DWGALM08/03/211ST SP SUBMITTAL09/27/2212/27/22----2ND SP SUBMITTAL3RD SP SUBMITTAL------18098.1812" NOTES: 1.USE TEFLON TAPE FOR ALL THREADED PIPE CONNECTIONS. 2.ALL WIRES TO BE INSTALLED AS PER LOCAL CODES. NO ''IN-LINE'' WIRE SPLICES WILL BE ALLOWED.24"PVC MALE ADAPTOR & LATERAL LINE FINISHED GRADE 12" STANDARD VALVE BOX DRAIN GRAVEL 1 CU. FOOT SCH.80 UNION CENTER VALVE IN BOX SCH.80 NIPPLE SCH.40 PVC SXT 90\ CLASS 200 PVC PIPE CONTROL WIRES SCH.40 PVC TEE OR 90 ANGLE TO DIRECT LATERAL IN TRENCH SUCH THAT PIPE IS NOT CURVED OR OTHERWISE STRESSED.DOUBLE VALVE BOXES BOLTED BACK TO BACK ELECTRIC CONTROL VALVE N.T.S.1 18" PLANS SECTIONS DIRECT BURY PLAN DIRECT BURY SECTION TAPE & BUNDLE ALL WIRING AT 10' INTERVALS. USE 6" WIDE MARKING TAPE 6" ABOVE ALL DIRECT BURIAL WIRING. ALL SPLICES SHALL BE MADE IN VALVE BOXES AND LOCATED ON AS-BUILT PLANS (ALL 120 V). WIRING SHALL BE IN CONDUIT WITH MARKER TAPE AS ABOVE. ALL WIRING UNDER PAVEMENT & THROUGH SLEEVES SHALL BE IN CONDUIT. TIE A LOOSE 20 INCH LOOP IN WIRING AT ALL CHANGES IN DIRECTION GREATER THAN 30 DEGREES. UNTIE ALL LOOPS AFTER MAKING CONNECTIONS. 18" CONDUIT SECTION CONDUIT PLAN 24" 36" 24" 36" LATERAL PIPE IN TRENCH SNAKE ALL FINISHED GRADE MARKING TAPE LOOP TIES FINISHED GRADE LATERAL MAIN LINE BEDDING LOW VOLTAGE WIRE OR 120V WIRE IN CONDUIT LATERAL TRENCHING DETAILS N.T.S.3 DRIPLINE EXHAUST HEADER MANUAL FLUSH VALVE PLUMBED TO PVC OR POLY SUPPLY HEADER VALVE, FILTER AND PRESSURE REGULATOR DRIPLINE N.T.S. NOTES: 1.INSTALL PER MANUFACTURERS SPECIFICATIONS. 2.SEE MANUFACTURERS GUIDE FOR DRIPLINE SPACING. 4 POP-UP SPRAY HEAD N.T.S. 4" FINISH GRADE POP-UP SPRINKLER BODY. SEE SPECIFICATION FOR TYPE. WALK/CURB (3) MARLEX STREET ELLS FLEXIBLE PIPE SCH. 40 P.V.C. TEE NOTES: 1. NIPPLE AND STREET ELL DIAMETERS SHALL EQUAL INLET SIZE SPRAY BODY. 5 POP-UP ROTOR N.T.S. 18" FINISH GRADE HUNTER I-20 USE FACTORY ASSEMBLED O RING SWING JOINT SEE SPECS. SCH. 40 P.V.C. TEE SQUARE PIECE OF SOD AROUND HEAD IN NEW SEEDED AREAS ONLY VARIES TOP SAND/TOPSOIL MIX 6 3" 12"12" 12" CONCRETE PAD PLAN 0.5% SLOPE 6"CONTROLLER ENCLOSURE INSTALL 3" HT. SELF ADHESIVE VINYL LETTERING CORRESPONDING WITH FIELD UNIT # ON INSIDE SURFACE OF ACCESS PANEL. CONCRETE PAD 8' MIN FROM CONTROLLER FINISHED GRADE 1/2" x 8' SOLID COPPER GROUNDING ROD W/ BRONZE 10 INCH ROUND VALVE BOX (TYPICAL). QUANTITY AS RECOMMENDED BY MANUFACTURER. #6 BARE COPPER GROUNDING WIRE 3/4" CONDUIT - GROUND WIRE 3" CONDUIT W/ SWEEP ELL - CONTROL WIRES 1" CONDUIT (CONTINUOUS) - 120v ELECTRICAL SERVICE CONTINUOUS FROM ELECTRIC METER. ELECTRICAL SERVICE FOR IRRIGATION SYSTEM IS CONSIDERED INCIDENTAL TO IRRIGATION SYSTEM. COORDINATE WITH CIVIL AND ELECTRICAL CONTROLLER ENCLOSURE CONTROLLER WITH PAD N.T.S.7 NOTE: COVER DRIP LATERAL AND EMITTER DISTRIBUTION TUBING WITH MULCH, ALL PLANTING BEDS. BURY TUBING AT 6" DEPTH IN OPEN AREAS. 'RAINBIRD EMITTER, INLINE OR XB-10,AT BASE OF EACH PLANTING RAINBIRD XT-700 1/2" DRIP TUBING MULCH, AS SPECIFIED 6" STL. STAPLE AT 6' O.C. MAXIMUM ALONG DRIP LATERAL; NOT REQUIRED WHERE DRIP LATERAL IS BURIED FINISH GRADE WEED BARRIER LANDSCAPE FABRIC, TYP. SECTION DRIP EMITTER N.T.S.8 3" 10" ROUND VALVE BOX BRAND "QC" INTO VALVE BOX FINISHED GRADE 3/4" CRUSHED GRAVEL ROCK SUMP - 1 CU. FT QUICK COUPLING VALVE WEED BARRIER FABRIC 1" PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) QUICK COUPLER VALVE STABILIZER 1" PVC SCH 80 FIPxFIP 90 ELL 1-1"X3" SCH.80 PVC NIPPLE 1" SCH.80 PVC FIPxFIP 90 ELL 1"X8" SCH.80 PVC NIPPLE 1-1"X 3" SCH.80 PVC NIPPLE 1" SCH.80 PVC FIPxFIP 90 ELL PRESSURE MAINLINE SERVICE TEE - SOLVENT WELD OR GASKETED FITTING. QUICK COUPLER VALVE N.T.S.9 ROTARY HEAD WITH SDR 35 PIPE N.T.S. USE FACTORY ASSEMBLED O RING SWING JOINT SEE SPECS. SDR 35 6" PIPE FOR HEAD PROTECTION IN DIRT JUMP AREA USE STAINLESS STEEL SELF FLUSHING HEADS USE TOPSOIL/SAND MIX TO BACK FILL HEAD SDR PIPE TO BE FLUSH WITH FINISH GRADE 6"10 p:\18098_18_westlake_bmx_track_landscape_&_design\CADD_C3D\production_dwg\18098_18_LS DETAILS.dwg, IRRIGATION DETAILS, 12/27/2022 2:50:49 PM, amartoncik, 1:1