Loading...
HomeMy WebLinkAbout070 E2.1.2 LEVEL 1 FLOOR PLAN -LIGHTINGFACPD D PP PP PP PP PP PP PP PP PP PP PP PP PP PP OS OS OS OS OS OS OS OS OS OS OS OS OS OS D OSLV LV PP PP PP OS LVLVPP PP LV LV OS LVLV PP PP OSOS PP OS LVLVLVLV LV LV LVD PP PP D OS OS OSD D PP LV LV PP PP LV LVLVPP PP PP PP PP PP PP PP PP PPLV LV PP PP PP PPPP LV3 5 64 C.1 C B A D 7 E MECH 120B IT 121 ENV 120A STAFF BREAK 124 G2 G3 G2 G3 G3 G3 1 U1 U1 U1 U1 U1 U1 S1 S1 S1 S1 CONSULT 123 CONSULT 122 CORRIDOR 132 STAFF TOILET 119 CLEAN LINEN 118 SOIL HOLD 117A CORRIDOR 131 LAUNDRY 117 VESTIBULE 116 CATERING/FOOD PREP 115 INVOL. PATIENT 114 INVOL. PATIENT 113 CORRIDOR 130 RESTRAINT ROOM 110 SALLY PORT 109 STORAGE 108 PATIENT 107 PATIENT 106 PATIENT 105 PATIENT 104 DAY ROOM / DINING 129 COMFORT SAFE ROOM 103 CONSULT 102 MEDS 127 LAB 126 C1 C1 C1 C1 B2 B2 WORK AREA 128A L1 L1 C1 B2B2 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 A1 A1 A1 A1 A1A1A1A1 A2 A2 A2 A2 C1 C1 C1 C1 C1 C1 C1 C1 A2 C1C1 C1 C1 C1C1 C1 C1 C1 C1C1 C1 C1 C1 B1 B1 B1 B1 B1 A2 A2 A2 A2 A2A2 C2 C2 C2 C2 C2 C2 A3 S2 S2 2 2 S2 S2 S2 S2 S2 S2 S2 S2 2 2 2 2 2 2 2 2 S2 S22 2 LED DRIVERS LED DRIVERS 3 3 B1 B1B1 B1 B1 B1 B1 B1 B1 B1 B2 B1 B1 B1 B1B1 B1 X1 X1 X1 X1 X1 X2 X2 X2 V1 V1 V1 X2 X2 V2 C1 C1 TOILET 111 TOILET 112 WAITING 101 4 C1 4 D-5 5 nPOD GFX a a a a a a a a b b b b b b b b b cc cc b b b a a b b b b a a b a a a a b b b b b a a aa b b b c c c c c b 6 C1 C1 C1C1 D-1 D-7 D-2 D-4 D-3 D-4 D-8 D-4 7 7 7 7 7 7 7 77 c cc U1 U1 4 4 a a a a b b b b U1 U1 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 S2 D-8 CLINIC STATION 128 d d d D-3 8 D-3 D-3 8 8 D-8 D-8 8 8 9 nD nD nER nD nD nD nD nD nD n n nDnD nD n nD nD nD nD n nS nnER n nD nD n n n n n n n n n n n c nER nER nER nER nER nLIGHT SYMBOL LEGEND nPOD WALL SWITCH, SUBSCRIPT INDICATES TYPE: nD nLV n nLIGHT POWER PACK/RELAY, SUBSCRIPT INDICATES TYPE: n nER nD nS nLIGHT OCCUPANCY SENSOR, SUBSCRIPT INDICATES TYPE: n10 PP OS n NOTE: BASIS OF DESIGN FOR DEVICES IS nLIGHT BY ACUITY BRANDS. ALL OTHER MANUFACUTURER'S MUST HAVE PRIOR APPROVAL FOR BIDDING. = NCM 10 = nPP16 = nPP16ER = nPP16D = nSP5 = nPODM DX = nPODM n S M O N T A N A PROF E SSIONA L E N G INEERLICENS E D T KNOLL JOHN PATRICK 13431 PE ACE JOB 22MS5546 12 N. BROADWAY SECOND FLOOR BELGRADE, MT 59714 406-388-3320 issue date project # phasesheet projectownerrevision date PERMIT SETaddress120 19TH AVE. SUITE HBOZEMAN, MONTANA 5971808/29/2022 8/29/2022 5:37:18 PME2.1.2 08/29/2022LEVEL 1 FLOOR PLAN - LIGHTING 22006.00 PERMIT SETSPANISH PEAKSCONNECTIONS HEALTH SOLUTIONSELECTRICAL KEYNOTES 1 COORDINATE INSTALLATION OF UNDER CABINET LIGHTING WITH CABINET PROVIDER. MOUNTED LIGHT FIXTURE ON BOTTOM SIDE OF CABINET. TYPICAL. 2 PROVIDE LED TAPE LIGHTING IN ARCHITECTURAL CEILING COVE. COORDINATE INSTALLATION WITH ARCHITECTURAL. 3 PROVIDE DRIVERS FOR LED TAPE LIGHTING IN ACCESSIBLE CEILING SPACE. TYPICAL. 4 PROVIDE RAZTRANS24 MVOLT TRANSFORMER FOR UNDER CABINET LIGHTING IN ACCESSIBLE CEILING SPACE. SEE ELECTRICAL DETAILS. 5 PROVIDE NSP5 PCD POWER PACK IN ACCESSIBLE CEILING SPACE FOR LED DRIVERS. WIRING CONFIGURATION TYPICAL OF ALL S2 STRIP LIGHTS. SEE ELECTRICAL DETAILS. 6 PROVIDE POWER PACK IN ACCESSIBLE CEILING SPACE FOR PATIENT ROOM LIGHTING. WIRING CONFIGURATION TYPICAL OF ALL PATIENT ROOMS. SEE ELECTRICAL DETAILS. 7 PROVIDE CAT6 CABLE TO CONNECT POWER PACK TO NPOD GFX CONTROLS. SEE ELECTRICAL DETAILS #4. 8 INSTALL POWER PACK IN ACCESSIBLE CEILING SPACE ABOVE CLINIC STATION. 9 PROVIDE NPOD GFX LIGHTING CONTROL IN SLOPED SURFACE OF CASEWORK. SEE ARCHITECTURAL DETAIL AND COORDINATE WITH CASEWORK PROVIDER. N.T.S.19 LEVEL 1 LIGHTING PLAN NORTH 0'4'2'4'8' SCALE : 1/4" = 1'-0" ELECTRICAL LIGHTING GENERAL NOTES A WHEN LIGHT SWITCHES ARE SHOWN LOCATED ON THE WALL THAT IS COMMON WITH THE END OF THE DOOR SWING INTO A SPACE. DO NOT LOCATE THE SWITCHES BEHIND THE DOOR, BUT RATHER A MINIMUM OF 6" FROM THE END OF THE SWING. VERIFY EXACT DOOR SWING PRIOR TO ROUGH-IN. B EC SHALL HAVE ALL EXPOSED RACEWAY AND CONDUIT SUPPORT SYSTEMS INSTALLED PRIOR TO GC PAINTING OF AREA SUCH THAT ITEMS ARE PROPERLY PAINTED TO MATCH EXPOSED AREAS OF BUILDING. COORDINATION OF EC INSTALL AND GC PAINING IS A MUST TO INSURE ALL SYSTEMS ARE PROPERLY COATED. EC SHALL REMOVE ALL LABELS AND OTHER ITEMS THAT WOULD IMPEDE PAINT ADHESION TO ELECTRICAL SYSTEMS. C ALL CABLING LOCATED WITHIN THE CEILING SPACE SHALL BE PLENUM RATED UNLESS IT IS COMPLETELY INSTALLED IN CONDUIT. THIS INCLUDES, BUT IS NOT LIMITED TO: OCCUPANCY SENSOR/ LIGHTING CONTROL CABLING. ALL FIRE ALARM CABLING SHALL BE IN A FULL CONDUIT SYSTEM, NO EXCEPTIONS. D OCCUPANCY SENSORS INSTALLED IN CLASSROOMS AND CORRIDORS SHALL BE SET FOR A 30 MINUTE TIME OUT DELAY. OFFICES SHALL BE SET FOR 15 MINUTE DELAY AND REST ROOMS SHALL BE SET FOR 20 MINUTE DELAY. E CONNECT ALL OCCUPANCY SENSORS AHEAD OF ANY WALL SWITCHES SUCH THAT OCCUPANCY SENSOR RECEIVES CONTINUOUS UN-SWITCHED POWER AND WALL SWITCH PROVIDES MANUAL/ LOCAL CONTROL. LIGHTS SHALL ONLY TURN ON IF SWITCHES ARE ON AND OCCUPANCY IS SENSED. EC SHALL WIRE ALL OCCUPANCY SENSOR SYSTEMS PER MANUFACTURERS RECOMMENDATIONS. F NOT ALL CIRCUITRY IS SHOWN FROM SWITCHES TO EACH CONTROLLED LIGHT FIXTURE(S). EC SHALL MATCH SWITCH SUBSCRIPT TO ASSOCIATED LIGHT FIXTURE(S) AND CONNECT COMPLETE. G PROVIDE ALL LOW VOLTAGE WIRING REQUIRED TO CONNECT OCCUPANCY SENSORS IN A SPACE TO THE POWER PACK ASSOCIATED WITH AN INDIVIDUAL AREA. WIRING NOT SHOWN FOR DRAWING CLARITY. H WHERE MULTIPLE OCCUPANCY SENSORS ARE IN A SINGLE ROOM, CONNECT SO THAT ANY SENSOR TURNS ALL LIGHTS ON. I EC SHALL PROVIDE A COMPLETE WIRING SYSTEM CONSISTING OF PROPER QUANTITY OF SWITCH LEGS, NEUTRALS AND HOT CIRCUITS FOR A FUNCTIONAL INSTALLATION. J PROVIDE UNSWITCHED HOT CONDUCTOR FROM LIGHTING CIRCUIT TO ALL EMERGENCY POWER PACKS OR EMERGENCY FIXTURES. WIRING NOT SHOWN.