HomeMy WebLinkAbout070 E2.1.2 LEVEL 1 FLOOR PLAN -LIGHTINGFACPD D
PP PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
PP
OS OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
D
OSLV
LV
PP
PP
PP
OS LVLVPP
PP
LV
LV
OS LVLV
PP
PP
OSOS
PP
OS LVLVLVLV
LV
LV
LVD
PP
PP
D
OS
OS
OSD D
PP
LV
LV
PP
PP
LV LVLVPP
PP
PP
PP PP
PP
PP
PP
PP
PPLV LV
PP
PP
PP
PPPP
LV3 5 64
C.1
C
B
A
D
7
E
MECH
120B
IT
121
ENV
120A
STAFF BREAK
124
G2
G3
G2
G3
G3
G3
1
U1
U1
U1
U1
U1
U1
S1
S1
S1
S1
CONSULT
123
CONSULT
122
CORRIDOR
132
STAFF TOILET
119
CLEAN LINEN
118
SOIL HOLD
117A CORRIDOR
131
LAUNDRY
117
VESTIBULE
116
CATERING/FOOD
PREP
115 INVOL. PATIENT
114 INVOL. PATIENT
113
CORRIDOR
130
RESTRAINT
ROOM
110
SALLY PORT
109 STORAGE
108
PATIENT
107
PATIENT
106
PATIENT
105
PATIENT
104
DAY ROOM /
DINING
129
COMFORT SAFE
ROOM
103
CONSULT
102
MEDS
127
LAB
126
C1 C1 C1
C1
B2 B2
WORK AREA
128A
L1
L1
C1
B2B2
C1
C1
C1
C1 C1
C1
C1
C1 C1
C1
C1
C1
C1
C1
C1
C1
C1
C1
A1
A1
A1
A1
A1A1A1A1
A2
A2
A2
A2
C1
C1
C1
C1 C1
C1 C1
C1
A2 C1C1
C1 C1
C1C1
C1 C1
C1
C1C1
C1
C1
C1
B1 B1
B1 B1
B1
A2
A2 A2
A2
A2A2
C2 C2 C2
C2
C2
C2
A3
S2
S2
2
2
S2
S2
S2
S2
S2 S2
S2
S2
2
2
2
2
2
2
2
2
S2
S22
2
LED DRIVERS
LED DRIVERS
3
3
B1
B1B1
B1
B1
B1
B1
B1
B1
B1
B2
B1
B1
B1
B1B1 B1
X1
X1
X1
X1
X1
X2
X2
X2
V1
V1
V1
X2
X2
V2
C1 C1
TOILET
111
TOILET
112
WAITING
101
4
C1
4 D-5
5
nPOD GFX
a
a a a
a
a
a
a
b
b
b b
b
b
b b
b
cc
cc
b
b
b
a
a
b
b
b
b
a
a
b
a
a a
a
b
b
b
b
b
a
a aa
b
b
b
c
c
c
c
c
b
6
C1 C1
C1C1
D-1
D-7
D-2
D-4
D-3
D-4
D-8
D-4
7
7
7
7
7
7
7
77
c
cc
U1 U1
4
4
a
a
a
a
b
b
b
b
U1
U1
C3
C3
C3 C3
C3 C3
C3 C3
C3 C3
C3
S2
D-8
CLINIC STATION
128
d
d
d
D-3
8
D-3
D-3
8
8
D-8
D-8
8
8
9
nD
nD
nER
nD nD nD
nD
nD
nD
n
n
nDnD
nD
n
nD
nD nD
nD
n
nS
nnER
n
nD
nD
n
n
n
n
n
n
n
n
n
n
n
c
nER
nER
nER
nER
nER
nLIGHT SYMBOL LEGEND
nPOD WALL SWITCH, SUBSCRIPT INDICATES TYPE:
nD
nLV
n
nLIGHT POWER PACK/RELAY, SUBSCRIPT INDICATES TYPE:
n
nER
nD
nS
nLIGHT OCCUPANCY SENSOR, SUBSCRIPT INDICATES TYPE:
n10
PP
OS n
NOTE:
BASIS OF DESIGN FOR DEVICES IS nLIGHT BY ACUITY BRANDS. ALL OTHER
MANUFACUTURER'S MUST HAVE PRIOR APPROVAL FOR BIDDING.
= NCM 10
= nPP16
= nPP16ER
= nPP16D
= nSP5
= nPODM DX
= nPODM
n
S
M O N T A
N
A
PROF
E
SSIONA L E N G INEERLICENS E D
T
KNOLL
JOHN PATRICK
13431 PE
ACE JOB 22MS5546
12 N. BROADWAY
SECOND FLOOR
BELGRADE, MT 59714
406-388-3320
issue date
project #
phasesheet projectownerrevision date
PERMIT SETaddress120 19TH AVE. SUITE HBOZEMAN, MONTANA 5971808/29/2022
8/29/2022 5:37:18 PME2.1.2
08/29/2022LEVEL 1 FLOOR PLAN - LIGHTING
22006.00
PERMIT SETSPANISH PEAKSCONNECTIONS HEALTH SOLUTIONSELECTRICAL KEYNOTES
1 COORDINATE INSTALLATION OF UNDER CABINET LIGHTING WITH CABINET PROVIDER.
MOUNTED LIGHT FIXTURE ON BOTTOM SIDE OF CABINET. TYPICAL.
2 PROVIDE LED TAPE LIGHTING IN ARCHITECTURAL CEILING COVE. COORDINATE
INSTALLATION WITH ARCHITECTURAL.
3 PROVIDE DRIVERS FOR LED TAPE LIGHTING IN ACCESSIBLE CEILING SPACE. TYPICAL.
4 PROVIDE RAZTRANS24 MVOLT TRANSFORMER FOR UNDER CABINET LIGHTING IN
ACCESSIBLE CEILING SPACE. SEE ELECTRICAL DETAILS.
5 PROVIDE NSP5 PCD POWER PACK IN ACCESSIBLE CEILING SPACE FOR LED DRIVERS. WIRING
CONFIGURATION TYPICAL OF ALL S2 STRIP LIGHTS. SEE ELECTRICAL DETAILS.
6 PROVIDE POWER PACK IN ACCESSIBLE CEILING SPACE FOR PATIENT ROOM LIGHTING.
WIRING CONFIGURATION TYPICAL OF ALL PATIENT ROOMS. SEE ELECTRICAL DETAILS.
7 PROVIDE CAT6 CABLE TO CONNECT POWER PACK TO NPOD GFX CONTROLS. SEE
ELECTRICAL DETAILS #4.
8 INSTALL POWER PACK IN ACCESSIBLE CEILING SPACE ABOVE CLINIC STATION.
9 PROVIDE NPOD GFX LIGHTING CONTROL IN SLOPED SURFACE OF CASEWORK. SEE
ARCHITECTURAL DETAIL AND COORDINATE WITH CASEWORK PROVIDER.
N.T.S.19 LEVEL 1 LIGHTING PLAN NORTH
0'4'2'4'8'
SCALE : 1/4" = 1'-0"
ELECTRICAL LIGHTING GENERAL NOTES
A WHEN LIGHT SWITCHES ARE SHOWN LOCATED ON THE WALL THAT IS COMMON WITH
THE END OF THE DOOR SWING INTO A SPACE. DO NOT LOCATE THE SWITCHES BEHIND
THE DOOR, BUT RATHER A MINIMUM OF 6" FROM THE END OF THE SWING. VERIFY
EXACT DOOR SWING PRIOR TO ROUGH-IN.
B EC SHALL HAVE ALL EXPOSED RACEWAY AND CONDUIT SUPPORT SYSTEMS INSTALLED
PRIOR TO GC PAINTING OF AREA SUCH THAT ITEMS ARE PROPERLY PAINTED TO MATCH
EXPOSED AREAS OF BUILDING. COORDINATION OF EC INSTALL AND GC PAINING IS A
MUST TO INSURE ALL SYSTEMS ARE PROPERLY COATED. EC SHALL REMOVE ALL LABELS
AND OTHER ITEMS THAT WOULD IMPEDE PAINT ADHESION TO ELECTRICAL SYSTEMS.
C ALL CABLING LOCATED WITHIN THE CEILING SPACE SHALL BE PLENUM RATED UNLESS IT
IS COMPLETELY INSTALLED IN CONDUIT. THIS INCLUDES, BUT IS NOT LIMITED TO:
OCCUPANCY SENSOR/ LIGHTING CONTROL CABLING. ALL FIRE ALARM CABLING SHALL
BE IN A FULL CONDUIT SYSTEM, NO EXCEPTIONS.
D OCCUPANCY SENSORS INSTALLED IN CLASSROOMS AND CORRIDORS SHALL BE SET FOR A
30 MINUTE TIME OUT DELAY. OFFICES SHALL BE SET FOR 15 MINUTE DELAY AND REST
ROOMS SHALL BE SET FOR 20 MINUTE DELAY.
E CONNECT ALL OCCUPANCY SENSORS AHEAD OF ANY WALL SWITCHES SUCH THAT
OCCUPANCY SENSOR RECEIVES CONTINUOUS UN-SWITCHED POWER AND WALL SWITCH
PROVIDES MANUAL/ LOCAL CONTROL. LIGHTS SHALL ONLY TURN ON IF SWITCHES ARE
ON AND OCCUPANCY IS SENSED. EC SHALL WIRE ALL OCCUPANCY SENSOR SYSTEMS PER
MANUFACTURERS RECOMMENDATIONS.
F NOT ALL CIRCUITRY IS SHOWN FROM SWITCHES TO EACH CONTROLLED LIGHT
FIXTURE(S). EC SHALL MATCH SWITCH SUBSCRIPT TO ASSOCIATED LIGHT FIXTURE(S) AND
CONNECT COMPLETE.
G PROVIDE ALL LOW VOLTAGE WIRING REQUIRED TO CONNECT OCCUPANCY SENSORS IN
A SPACE TO THE POWER PACK ASSOCIATED WITH AN INDIVIDUAL AREA. WIRING NOT
SHOWN FOR DRAWING CLARITY.
H WHERE MULTIPLE OCCUPANCY SENSORS ARE IN A SINGLE ROOM, CONNECT SO THAT
ANY SENSOR TURNS ALL LIGHTS ON.
I EC SHALL PROVIDE A COMPLETE WIRING SYSTEM CONSISTING OF PROPER QUANTITY OF
SWITCH LEGS, NEUTRALS AND HOT CIRCUITS FOR A FUNCTIONAL INSTALLATION.
J PROVIDE UNSWITCHED HOT CONDUCTOR FROM LIGHTING CIRCUIT TO ALL EMERGENCY
POWER PACKS OR EMERGENCY FIXTURES. WIRING NOT SHOWN.