Loading...
HomeMy WebLinkAbout068 ED2.1.1 LEVEL 1 FLOOR PLAN -LIGHTING DEMOLITION PLAND 3 5 64 C.1 C B A D 7 E 1 2 2 M O N T A N A PROF E SSIONA L E N G INEERLICENS E D T KNOLL JOHN PATRICK 13431 PE ACE JOB 22MS5546 12 N. BROADWAY SECOND FLOOR BELGRADE, MT 59714 406-388-3320 issue date project # phasesheet projectownerrevision date PERMIT SETaddress120 19TH AVE. SUITE HBOZEMAN, MONTANA 5971808/29/2022 8/29/2022 5:37:20 PMED2.1.1 08/29/2022LEVEL 1 FLOOR PLAN - LIGHTING DEMOLITION PLAN 22006.00 PERMIT SETSPANISH PEAKSCONNECTIONS HEALTH SOLUTIONSN.T.S.19 LEVEL 1 LIGHTING SYSTEMS DEMOLITION PLAN TRUE NORTH 0'4'2'4'8' SCALE : 1/4" = 1'-0" ELECTRICAL GENERAL DEMOLITION NOTES I ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH NEC, STATE AND LOCAL BUILDING CODE. J PRESENT ANY USABLE/ SALVAGEABLE ELECTRICAL DEVICES TO OWNER INCLUDING BUT NOT LIMITED TO: LIGHT FIXTURES, ELECTRICAL HEATERS, PANELS, CIRCUIT BREAKERS ETC. REMOVE ALL UNCLAIMED ITEMS AND DISPOSE IN ACCORDANCE WITH ALL REGULATIONS AND STANDARDS. K ALL DASHED ITEMS ON DEMOLITION PLANS ARE TO BE REMOVED UNLESS NOTED OTHERWISE. SOLID ITEMS ARE TO REMAIN OR TO BE RELOCATED AS NOTED. L ANY WORK THAT REQUIRES POWER DISRUPTIONS SHALL BE SCHEDULED AND APPROVED BY THE OWNER. ALL WORK SHALL BE PERFORMED WITH NO DISRUPTION OF THE OWNER'S BUSINESS. ELECTRICAL GENERAL DEMOLITION NOTES A INTENT OF DEMOLITION WORK IS TO REMOVE ALL ELECTRICAL SYSTEMS WITHIN THE PROJECT AREA IN PREPARATION FOR RENOVATION WORK. THIS INCLUDES ALL DEVICES, WIRING, FIXTURES, AND ABANDONED SYSTEMS CABLING. FIRE ALARM CABLING COMING FROM THE ADJOINING SPACE SHOULD BE REMOVED BACK TO PROJECT BOUNDARY. B ALL DEVICE AND EQUIPMENT SHOWN ARE BASED ON LIMITED FIELD OBSERVATIONS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND MAKE ALLOWANCE IN THEIR BID TO ACCOUNT FOR ALL EXISTING CONDITIONS THAT AFFECT THEIR WORK. C EXISTING WIRING METHODS OBSERVED IN THE PROJECT AREA DO NOT COMPLY WITH REQUIREMENTS FOR THE PLANNED FUTURE USE AS A HEALTHCARE FACILITY IN ACCORDANCE WITH 2017 NEC 517.13(A). ALL WIRING THAT DOES NOT COMPLY WITH THIS REQUIREMENT SHALL BE REMOVED. D ELECTRICAL CONTRACTOR SHALL REMOVE ALL ELECTRICAL DEVICES IN AREAS OF THIS FACILITY AFFECTED BY REMODEL WORK INCLUDING BUT NOT LIMITED TO: JUNCTION BOXES, OUTLETS, LIGHTS, CABLE, CONDUIT AND WIRE. ALL DEVICES MAY NOT BE SHOWN ON THIS SHEET AND SITE INVESTIGATION IS REQUIRED FOR EXACT QUANTITIES. CONFIRM DEMOLITION SCOPE WITH GENERAL CONTRACTOR AT PRE-BID WALK AND RECYCLE WHERE FEASIBLE. DISPOSE OF ALL FLUORESCENT LAMPS AND BALLASTS IN A LEGAL AND ENVIRONMENTALLY FRIENDLY MANNER. PROVIDE PROPER DISPOSAL DOCUMENTATION STATING ITEMS DISPOSED OF AND QUANTITY TO OWNER FOR RETENTION. E EXISTING CONDUITS STUBBED THROUGH THE FLOOR THAT ARE NOT REUSED OR ARE ABANDONED SHALL BE REMOVED. F RETAIN ALL FIRE ALARM DEVICES FOR REUSE. RETURN ALL UNUSED FIRE ALARM DEVICES TO THE OWNER. G PROVIDE NEW CONDUCTORS IN EXISTING RACEWAYS THAT ARE FEASIBLE TO RE-USE. USE EXISTING BACKBOXES WITH NEW DEVICES IN APPROPRIATE AREAS. H REMOVE ALL WIRING FROM DESTINATION POINT BACK TO SOURCE AS NO EXISTING WIRING MAY BE REUSED IN THE NEW ELECTRICAL WORK. EXISTING CONDUITS AND PATHWAYS MAY BE REUSED IF THEY MEET THE PROJECT REQUIREMENTS. ELECTRICAL KEYNOTES 1 REMOVE EXIT SIGN FOR REPLACEMENT. 2 REMOVE ILLUMINATED EXTERIOR SIGN AND ASSOCIATED CIRCUITS.