Loading...
HomeMy WebLinkAbout017 A2.2.1 ROOF PLANM M M M M M DSDDSDDSD DSDDSDDSD DSDDSD1. REFER TO ALL DRAWINGS FOR ADDITIONAL INFORMATION CONCERNING THE WORK. NOTIFY ARCHITECT IMMEDIATELY OF ANY CONFLICT PRIOR TO COMMENCING WORK. 2. PROVIDE ROOF CRICKETS AT ALL UPSLOPE AREAS OF MECHANICAL EQUIPMENT, CURBS AND ROOF HATCHES. 3. CRICKETS TO SLOPE POSITIVELY TWICE THE FIELD SLOPE MINIMUM PER FOOT FROM HORIZONTAL PLANE. 4. MAINTAIN 1/8" PER FOOT MINIMUM FOR ALL CRICKET VALLEYS. 5. CRICKETS SHOWN ARE FOR REFERENCE ONLY; CONTRACTOR TO PROVIDE DETAILED LAYOUT PLAN FOR ARCHITECT'S REVIEW PRIOR TO INSTALLATION. 6. ROOF PENETRATIONS OF ANY KIND SHALL NOT BE LOCATED IN CRICKET VALLEYS. 7. IN ADDITION TO OPENING AND EQUIPMENT SHOWN ON THIS DRAWING, MECHANICAL AND ELECTRICAL DRAWINGS 8. INDICATE ADDITIONAL ITEMS PENETRATING THE ROOF ASSEMBLY; PROVIDE APPROPRIATE FLASHING. 9. REFERENCE MECH DRAWINGS FOR VENT LOCATIONS, EQUIPMENT LOCATIONS, AND ADDITIONAL INFORMATION, TYP. ROOF PLAN NOTES 5 64 C.1 C B A4.1.1 5 A4.1.1 1 A4.1.1 13 3 A D 7 E D4.1.1 1 D4.1.1 13 D4.1.1 9 SECURED ROOF ACCESS EXISTING RTUEXISTING RTU SCALE: 1/8" = 1'-0" 8'6'4'2'8'16'0' NORTH EXHAUST FAN, SEE MECHANICAL DRAWINGS EXHAUST FAN, SEE MECHANICAL DRAWINGS 07-03 07-03 07-04 07-0407-07 07-07 07-06 07-05 07-06 NOTE: SEE MECHANICAL DRAWINGS FOR EXTENT OF SCOPE OF GAS LINE INSTALL WITHIN WORK IN SHADED AREA GENERATOR SEE CIVIL FOR SITE WORK A4.1.2 8 A5.3.1 1 07-08 07-08 07-07 07-08 PROTECT ROOF DURING INSTALLATION OF EQUIPMENT AND PIPES; REPAIR / RESTORE ROOFING CONDITIONS TO NON-LEAK PRE-EXISTING CONDITIONS 07-05 07-0807-04 07-06 05-01 6' - 0" 20' - 0" issue date project # phasesheet projectownerrevision dateaddress PERMIT SET8/29/2022 5:32:11 PMA2.2.1 08/29/2022ROOF PLAN22006.00 PERMIT SETSPANISH PEAKSCONNECTIONS HEALTH SOLUTIONS120 19TH AVE. SUITE HBOZEMAN, MONTANA 5971805-01 42" HIGH GALVANIZED STEEL RAILING, PAINT BLACK 07-03 RELOCATED RTU, SEE MECHANICAL DRAWINGS; EXACT RTU TO BE DETERMINED AFTER EXPLORATORY LOCATION DETERMINED 07-04 CONDUCT EXPLORATORY WORK TO FIND LOCATION OF JOINTS OF SIPS TYPE PANEL USED IN EXISTING CONSTRUCTION; RTU'S TO BE LOCATED IN CENTER OF JOINTS 07-05 REPLACE, PATCH AND SEAL EPDM ROOFING TO MATCH EXISTING 07-06 INSTALL ROOF CRICKETS AT RELOCATED RTU 07-07 INSTALL SINGLE SLOPE TYPE PLYWOOD CLOSURE AND WITH SUPPORTS OVER EXISTING RTU CURB FROM REMOVED UNIT, FILL VOID WITH BATT INSULATION. 07-08 EXTEND ROOFING MEMBRANE REPAIR 2' MINIMUM AT PERIMETER OF NEW INSTALLATION, SEAL AS RECOMMENDED BY ROOFING MANUFACTURER WITH COMPATIBLE PRODUCTS KEYNOTES 1/8" = 1'-0"13 ROOF