HomeMy WebLinkAbout017 A2.2.1 ROOF PLANM
M
M
M
M
M
DSDDSDDSD
DSDDSDDSD
DSDDSD1. REFER TO ALL DRAWINGS FOR ADDITIONAL INFORMATION CONCERNING THE WORK. NOTIFY
ARCHITECT IMMEDIATELY OF ANY CONFLICT PRIOR TO COMMENCING WORK.
2.
PROVIDE ROOF CRICKETS AT ALL UPSLOPE AREAS OF MECHANICAL EQUIPMENT, CURBS AND
ROOF HATCHES.
3. CRICKETS TO SLOPE POSITIVELY TWICE THE FIELD SLOPE MINIMUM PER FOOT FROM
HORIZONTAL PLANE.
4. MAINTAIN 1/8" PER FOOT MINIMUM FOR ALL CRICKET VALLEYS.
5. CRICKETS SHOWN ARE FOR REFERENCE ONLY; CONTRACTOR TO PROVIDE DETAILED LAYOUT
PLAN FOR ARCHITECT'S REVIEW PRIOR TO INSTALLATION.
6. ROOF PENETRATIONS OF ANY KIND SHALL NOT BE LOCATED IN CRICKET VALLEYS.
7. IN ADDITION TO OPENING AND EQUIPMENT SHOWN ON THIS DRAWING, MECHANICAL AND
ELECTRICAL DRAWINGS
8. INDICATE ADDITIONAL ITEMS PENETRATING THE ROOF ASSEMBLY; PROVIDE APPROPRIATE
FLASHING.
9. REFERENCE MECH DRAWINGS FOR VENT LOCATIONS, EQUIPMENT LOCATIONS, AND ADDITIONAL
INFORMATION, TYP.
ROOF PLAN NOTES
5 64
C.1
C
B
A4.1.1
5
A4.1.1
1
A4.1.1
13
3
A
D
7
E
D4.1.1
1
D4.1.1
13
D4.1.1
9
SECURED ROOF
ACCESS
EXISTING RTUEXISTING RTU
SCALE: 1/8" = 1'-0"
8'6'4'2'8'16'0'
NORTH
EXHAUST FAN, SEE
MECHANICAL DRAWINGS
EXHAUST FAN, SEE
MECHANICAL DRAWINGS
07-03
07-03
07-04
07-0407-07
07-07
07-06
07-05
07-06
NOTE:
SEE MECHANICAL DRAWINGS FOR
EXTENT OF SCOPE OF GAS LINE INSTALL
WITHIN WORK IN SHADED AREA
GENERATOR
SEE CIVIL FOR SITE WORK
A4.1.2
8
A5.3.1
1
07-08
07-08
07-07
07-08
PROTECT ROOF DURING INSTALLATION OF EQUIPMENT
AND PIPES; REPAIR / RESTORE ROOFING CONDITIONS
TO NON-LEAK PRE-EXISTING CONDITIONS
07-05
07-0807-04
07-06
05-01
6' - 0"
20' - 0"
issue date
project #
phasesheet projectownerrevision dateaddress
PERMIT SET8/29/2022 5:32:11 PMA2.2.1
08/29/2022ROOF PLAN22006.00
PERMIT SETSPANISH PEAKSCONNECTIONS HEALTH SOLUTIONS120 19TH AVE. SUITE HBOZEMAN, MONTANA 5971805-01 42" HIGH GALVANIZED STEEL RAILING, PAINT BLACK
07-03 RELOCATED RTU, SEE MECHANICAL DRAWINGS; EXACT RTU TO BE
DETERMINED AFTER EXPLORATORY LOCATION DETERMINED
07-04 CONDUCT EXPLORATORY WORK TO FIND LOCATION OF JOINTS OF SIPS TYPE
PANEL USED IN EXISTING CONSTRUCTION; RTU'S TO BE LOCATED IN CENTER
OF JOINTS
07-05 REPLACE, PATCH AND SEAL EPDM ROOFING TO MATCH EXISTING
07-06 INSTALL ROOF CRICKETS AT RELOCATED RTU
07-07 INSTALL SINGLE SLOPE TYPE PLYWOOD CLOSURE AND WITH SUPPORTS
OVER EXISTING RTU CURB FROM REMOVED UNIT, FILL VOID WITH BATT
INSULATION.
07-08 EXTEND ROOFING MEMBRANE REPAIR 2' MINIMUM AT PERIMETER OF NEW
INSTALLATION, SEAL AS RECOMMENDED BY ROOFING MANUFACTURER WITH
COMPATIBLE PRODUCTS
KEYNOTES
1/8" = 1'-0"13 ROOF