HomeMy WebLinkAbout014 A2.1.2 LEVEL 1 FLOOR PLANTT TSS
T T
S
CR
CRCR
CRCR
CRCRCR
CRCRCR
CR
CR
CR
CR CRCRCR
CRCRCR
CRCRCRCR
CR
CR CRCRCRCR
CRCR
CRESESESESES ESESESESESESESES
ESESESESESESES
ESESESES ESFFFACP
FAAFPB
ESDCVBVB VB
CCTV
FWPESES
ESCR
FS FS
TS TS TS
NOT IN SCOPE
5 64
C.1
C
B
A4.1.1
13
WAITING
101
STAFF BREAK
124
CONSULT
123
CONSULT
122
CORRIDOR
132 PUBLIC
TOILET
125
IT
121
MECH
120B
LAB
126
STAFF TOILET
119
LAUNDRY
117
3
CONSULT
102
COMFORT
SAFE ROOM
103
PATIENT
104
PATIENT
105
PATIENT
106
PATIENT
107
STORAGE
108
SALLY PORT
109
RESTRAINT
ROOM
110
TOILET
111
TOILET
112
VESTIBULE
116
INVOL.
PATIENT
113
INVOL.
PATIENT
114CATERING/FOOD
PREP
115
CLEAN LINEN
118
DAY ROOM /
DINING
129
CORRIDOR
130
CORRIDOR
131
A5.1.1
1
A5.1.1
1
A
D
7
E
A6.1.3
20
A6.2.18
22
19 21
ENV
120A
A6.1.2
101.0102.0
124.0102.1103.0E E
E
E
E 109.0107.0
106.0
105.0111.0112.0113.0114.0115.0117A.0
119.0
121.0122.0125.0
128A.0 127.0126.0128.1132.0
104.0
108.0
130.0 109.1110.0
120.0131.0118.0116.0A6.1.2 98
A6.1.1
16
1715
18
A6.1.11 3
76
A6.1.2
15
A6.1.2
A6.1.3 3
A6.1.3
10
A6.1.3
14
2
1
4
A6.2.1
2
1
A6.2.1
9
12
5 11
54
16
13 15
9
8
7
A6.2.1
3
4
7
A6.1.221
22
MEDS
127
A6.1.2
26
A6.1.227
28
23
24
25
A6.1.2
18
CLINIC
STATION
128
A6.1.2 17
A6.1.2
2
31
19
20A6.1.211
12
13
14A6.1.2
10
112B.0112A.0
117.0
SOIL HOLD
117A
TOILET
112A
TOILET
112B
A6.1.1
2
A6.1.1
14
13
1112
A6.1.15
6
7
ATS
WALL
MOUNTED
TE CAB
4
WORKSTATION
ADAPTABLE ADA
09-03
09-03
09-0209-02WORK AREA
128A
A5.2.1
16
A5.1.1
11
A5.1.1
11
09-06
EQ-03
A6.1.19EQ-05EQ-04EQ-01 EQ-02
10
A6.4.1
8
A6.4.1
16
A9.3.2
3 A9.3.2
8
A9.3.2
12
WP-1
WP-1
WP-1
WP-1
WP-1
WP-1
WP-1
FECAL-1
FECAL-1128.0A9.1.2
15
SCALE: 1/4" = 1'-0"
4'3'2'1'4'8'0'
NORTH
A9.1.2
13
A9.3.2
4116.1CG-2
CG-2
CG-2
CG-2
CG-4
CG-4
CG-3
CG-3 CG-3
CG-3
CG-3 TA-10
TA-24
TA-21.1
TA-21.2
TA-21.3
TA-32
TA-27
TA-11
TA-11
TA-10
TA-11
TA-33
TA-10
TA-14
TA-10
TA-14
TA-51
TA-53
TA-03
TA-02
TA-01
TA-07
TA-14
TA-12
TA-10
TA-11
TA-14
TA-10 TA-10
TA-14
TA-11
MON-01
A9.3.2
16
A6.1.317
18
TA-24
TA-25
TA-21.1
TA-21.2
124.1123.0TA-26
TA-33
TA-14
TA-11
(2)
TA-53
(3)
TA-53
(6)
(2)
WDAL-1
117.1
TA-53
(4)
TA-25
TA-21.4
TA-21.4
TA-22
TA-22
TA-22
TA-22
CG-1
CG-1
TA-11
TA-10
TA-14
A5.2.1
15
A5.2.1
13
TA-22
TA-22
TA-22 TA-22 TA-21.2
TA-21.3
TA-21.1
8
TA-34
08-03 08-03
TA-22
TA-22
CG-3
SEE FURNITURE PLAN FOR
NOTES ON RESTRAINT BED
03-01
03-01
08-01 08-01
SINK-1
SINK-1
SINK-2
SINK-1
09-25
09-25
09-0909-09 09-09
09-09
09-09
09-09
09-09
09-09
09-09
09-09
09-09
1. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL
INFORMATION. ALL INFORMATION REGARDING EXISTING CONDITIONS IS BASED UPON
OWNER-SUPPLIED DOCUMENTS AND MAY NOT PRECISELY REFLECT FIELD CONDITIONS.
2. THE CONTRACTOR SHALL NOT CONSIDER CONSTRUCTION NOTES TO BE ALL-INCLUSIVE.
IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT AND ASSESS EACH AREA AND TO
FULFILL THE INTENT OF THE CONTRACT DOCUMENTS. CONTRACTOR SHALL COORDINATE
ARCHITECTURAL CONSTRUCTION DRAWING AND NOTES WITH CIVIL, STRUCTURAL AND
MECHANICAL, ELECTRICAL & PLUMBING NOTES AND DRAWINGS.
3. FIELD VERIFY ALL DIMENSIONS. DO NOT SCALE DRAWINGS.
4. ALL FINISHES AND MATERIALS SHALL BE PROPERLY INTEGRATED TO ENSURE A UNIFORM
APPEARANCE AND SEAMLESS TRANSITION.
5. PROVIDE ALL BLOCKING FOR MILLWORK, GRAB BARS, MONITORS, CRASH RAILS AND ANY
AND ALL WALL MOUNTED EQUIPMENT OR ACCESSORIES; COORDINATE LOCATIONS.
6. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED FACE OF STUD, UNLESS
OTHERWISE NOTED.
7. GENERAL CONTRACTOR SHALL COORDINATE ALL ASPECTS OF THE BUILDING
CONSTRUCTION.
8. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND REPAIR ALL
INCONSISTENCIES IN FLOOR ELEVATIONS.
9. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO PROVIDE SUITABLE
SUBSTRATE FOR FINISHES.
10. U.L. ASSEMBLIES DESCRIBED ARE FOR REFERENCE ONLY. THE GENERAL CONTRACTOR
SHALL COORDINATE AND VERIFY THE INSTALLATION OF THE DESCRIBED SYSTEM(S) .
11.
12. REFER TO DOOR AND FRAME SCHEDULE FOR DOORS REQUIRING ADA ACCESS CONTROL.
13. LOCATE THE HINGE SIDE JAMB OF DOORS 4" FROM ADJACENT PERPENDICULAR WALL,
UNLESS NOTED OTHERWISE.
14. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP AND BOTTOM, AND
PENETRATIONS, AND INSTALL PUTTY PADS AROUND ELECTRICAL BOXES WHERE
PARTITION CONTAINS ACOUSTICAL INSULATION.
15. REFER TO SPECIFICATIONS FOR CODE REQUIRED SIGNAGE. PROVIDE ADDITIONAL
SIGNAGE AS MAY BE REQUIRED BY REQUEST OF THE FIRE MARSHAL AND/OR BUILDING
CODE OFFICIAL.
FLOOR PLAN NOTES
1-HOUR FIRE RATED PARTITION
NON-RATED SECURITY PARTITION EXTEND FROM FLOOR
TO UNDERSIDE OF STRUCTURE WITH GYPSUM BOARD
BOTH SIDES OF PARTION
WALL PARTITION LEGEND
EXISTING NON-RATED WALL CONVERTED TO UL DES NO. 465,
1-HOUR FIRE RATED PARTITION
issue date
project #
phasesheet projectownerrevision dateaddress
PERMIT SET8/29/2022 5:31:30 PMA2.1.2
08/29/2022LEVEL 1 FLOOR PLAN22006.00
PERMIT SETSPANISH PEAKSCONNECTIONS HEALTH SOLUTIONS120 19TH AVE. SUITE HBOZEMAN, MONTANA 5971803-01 SEE CIVIL DRAWINGS FOR EXTENT OF P.I.P. CONCRETE SIDE WALK
08-01 3/8"T MINIMUM POLYCARBONTE WINDOW PROTECTION; PROVIDE 3" TEMPER PROOF MECHANICALLY
FASTENERS AT 8" O.C. AT PERIMETER. SEAL PERIMETER OF POLYCARBONATE TO WALL; INSTALL SAND
BLASTED FILM-3 IN FULL POLYCARBONATE MATERIAL FACING THE STOREFRONT
08-03 1/2" MINIMUM THICKNESS POLYCARBONATE WINDOW PROTECTION. PROVIDE 2" WIDERED THAN EDGE AT
PERIMETER OF OPENING; MECHANICALLY FASTENED WITH TEMPER PROOF FASTENERS; AT 8" O.C. AT
PERIMETER; INSTALL SAND BLASTED FILM-3 IN FULL POLYCARBONATE MATERIAL FACING THE STOREFRONT
09-02 18"D HEAVY DUTY STAINLESS STEEL WIRE ADJUSTABLE SHELVING WITH 1" STAINLESS STEEL LIP. PROVIDE
HEAVY DUTY STAINLESS STEEL STANDARDS AT 32" O.C. MAX. LOCATE AT STUD OR ADD BLOCKING AS
NEEDED PRIOR TO SHELF INSTALLATION.
09-03 24"D HEAVY DUTY STAINLESS STEEL WIRE ADJUSTABLE SHELVING WITH 1" STAINLESS STEEL LIP. PROVIDE
HEAVY DUTY STAINLESS STEEL STANDARDS AT 32" O.C. MAX. LOCATE AT STUD OR ADD BLOCKING AS
NEEDED PRIOR TO SHELF INSTALLATION.
09-06 EXISTING CRAWL SPACE ACCESS WITH NEW FLOORING MATERIAL TO MATCH SPECIFIED ADJACENT
FLOORING
09-09 INSTALL GBI-1 ENTIRE PERIMETER OF ROOM
09-25 PROVIDE A COMBINATION OF GB-3: 1/4" THICKNESS AND 3/8" THICKNESS FOR A TOTAL 5/8" THICKNESS AT
CURVED WALL.
1/4" = 1'-0"13 LEVEL 1 FLOOR PLAN
KEYNOTES