HomeMy WebLinkAbout012 A1.2.1 ASSEMBLY TYPESEXAMPLE:= TYPE 'A' WALL, WITH 6" STUDS, TILE BACKER BOARD ('T'), AND A 2-HOUR FIRE RATING (PER U.L. DESCRIPTION) ADDITIONAL WALL COMPONENTS: SOUND BATTS (S)/ TILE BACKER (T)/ WET WALL (W)/ PARTIAL HEIGHT (P)/ VAPOR PERMEABLE AIR BARRIER (V) LOW WALL (L) ACOUSTICAL STC RATING TYPE (A - Z) STUD/MATERIAL WIDTH 1 B-4 T WALL TYPE LEGEND FIRE RATING 2A-6T FIN. FLOOR, TYP. UNDERSIDE OF DECK OR BEAM ABOVE, TYP. CONT. SEALANT BOTH SIDES, TYP. SYMBOL: CONT. SEALANT BOTH SIDES, TYP. STUD SIZE WALL TYPE METAL STUD WITH GB-1 EACH SIDE SLIP TRACK A SERIES PARTITIONA 1 5/8" (1) 2 1/2" (2) 3 5/8" (3) 6" (6)A-6 1-HOUR RATING UL DES U465 (MTL) FIN. FLOOR, TYP. UNDERSIDE OF DECK OR BEAM ABOVE, TYP. CONT. SEALANT BOTH SIDES, TYP. CONT. SEALANT BOTH SIDES, TYP. METAL STUD WITH 1 LAYER GBX-1 EACH SIDE SLIP TRACK 1 5/8" (1) 2 1/2" (2) 3 5/8" (3) 6" (6) FIN. FLOOR, TYP. UNDERSIDE OF DECK OR BEAM ABOVE, TYP. CONT. SEALANT BOTH SIDES, TYP. CONT. SEALANT BOTH SIDES, TYP. GBI-1 SLIP TRACK 6" (6)A-6A2 A SERIES ACOUSTICAL PARTITIONS NON-RATED 3/4" HAT ONE-LEGGED CHANELS AT 24" O.C., VERTICALLY METAL STUD AT 16" O.C. FILL CAVITY WITH ACOUSTICAL GLASS BATT INSULATION ACOUSTICAL DESIGNATION FIN. FLOOR, TYP. UNDERSIDE OF DECK OR BEAM ABOVE, TYP. CONT. SEALANT BOTH SIDES, TYP. CONT. SEALANT BOTH SIDES, TYP. 24 GA METAL STUDS AT 16" O.C. SLIP TRACK 3 5/8" (3) A-3A1 FILL CAVITY WITH FIBER GLASS ACOUSTICAL INSULATION GB-1 7/8" FURRING CHANNEL AT 16" O.C. VERTICALLY AND RESILIENT ISOLATION CLIPS STUD SIZE GBI-1 GB-1 3 5/8" (3) SYMBOL: STUD SIZE WALL TYPE 1A-6 SYMBOL: STUD SIZE WALL TYPE STC 58 ACOUSTICAL DESIGNATION SYMBOL: WALL TYPE STC 63 GBI-1 GB-1 GBI-1 6" (6) 1 5/8" FIN. FLOOR, TYP. UNDERSIDE OF DECK OR BEAM ABOVE, TYP. CONT. SEALANT, TYP. SYMBOL: CONT. SEALANT, TYP. STUD SIZE WALL TYPE METAL STUD GB-1 ONE SIDE SLIP TRACK B SERIES PARTITIONB 1 5/8" (1) 2 1/2" (2) 3 5/8" (4) 6" (6) B-6 GENERATOR SIDE E SERIES EXTERIOR WALL ASSEMBLIESE E7-01 7 5/8" GROUND FACE CMU, SEE STRUCTURAL FOR REINFORCEMENT EXTERIOR 7 5/8" VERTICAL ORIENTED WATER MANAGEMENT SYSTEM BY E.I.F.S MANUFACTURER 2" XPS RIGID INSULATION AB-2 BASE COAT FINISH COAT, MATCH TEXTURE OF EXISTING INSTALLATION METAL OR WOOD STUD TO MATCH EXISTING CONSTRUCTION WALL THICKNESS GB1-1 WHERE APPLICABLE EXTERIORINTERIOR 6E-01 3" INSUL-8 1/2" 3/8" WATER MANAGEMENT 2" PLYWOOD SHEATHING TO MATCH EXISTING THICKNESS AB-2 LAP SIDING TO MATCH EXISTING METAL OR WOOD STUD TO MATCH EXISTING CONSTRUCTION WALL THICKNESS GB1-1 WHERE APPLICABLE EXTERIORINTERIOR 6E-02 INSUL-4 1/2" 3 FIN. FLOOR, TYP. UNDERSIDE OF DECK OR BEAM ABOVE, TYP. SYMBOL: WALL SIZE WALL TYPE PRIMARY WALL PARTITION ASSEMBLY AS NOTED ON FLOOR PLANS W SERIES PARTITIONW 1 1/2" (2) WP-2 7/16" OSB MECHANICAL FASTENED TO PRIMARY WALL AND CEILING METAL STUD CEILING DESIGNED TO SUPPORT 5 LBS / SF GB-1 SAFETY PADS BY OWNER VENDOR; COORDINATE LOCATION OF FASTENERS AND VENDOR DRAWERS FOR PROPER PRIMARY WALL, CEILING, AND OSB SUBSTRATE PREPARATION issue date project # phasesheet projectownerrevision dateaddress BID SET10/31/2022 9:28:59 AM11-01-223 A1.2.1 09/15/2022ASSEMBLY TYPES22006.00 BID SET SPANISH PEAKSCONNECTIONS HEALTH SOLUTIONS120 19TH AVE. UNIT 1BOZEMAN, MONTANA 59718VERTICAL ASSEMBLIES HORIZONTAL ASSEMBLIES 1. NO NEW HORIZONTAL ASSEMBLIES 2. EXISTING HORIZONTAL ROOF ASSEMBLIES TO MATCH EXISTING, COORDINATE WITH STRUCTURAL DRAWINGS FOR BRACING OF EXISTING ROOF WHERE ROOF TOP UNITS REQUIRE BRACING.