HomeMy WebLinkAbout004 G1.1.1 LEVEL 1 CODE PLAN5 64
C.1
C
B
3
A
D
7
E
225 SF
WAITING
101
175 SF
STAFF BREAK
124
104 SF
CONSULT
123
109 SF
CONSULT
122
224 SF
CORRIDOR
132 49 SF
PUBLIC
TOILET
125
32 SF
IT
121
63 SF
MECH
120B
63 SF
LAB
126
46 SF
STAFF TOILET
119
56 SF
LAUNDRY
117
94 SF
CONSULT
102
96 SF
COMFORT
SAFE ROOM
103 189 SF
PATIENT
104
163 SF
PATIENT
105
165 SF
PATIENT
106
162 SF
PATIENT
107
86 SF
STORAGE
108
76 SF
SALLY PORT
109
110 SF
RESTRAINT
ROOM
110
57 SF
TOILET
11165 SF
TOILET
112
22 SF
VESTIBULE
116
81 SF
INVOL.
PATIENT
113
82 SF
INVOL.
PATIENT
114
163 SF
CATERING/FOOD
PREP
115
60 SF
CLEAN LINEN
118
625 SF
DAY ROOM /
DINING
129
132 SF
CORRIDOR
130
128 SF
CORRIDOR
131
EXIT DOOR
18
34" 170
101.0
EXIT DOOR
19
34" 170
109.1
PATH OF TRAVEL = 55 FTPATH OF TRAVEL = 57 FT
R-4 OCCUPANCY
3,560 SF
SCALE: 1/8" = 1'-0"
8'6'4'2'8'16'0'
NORTH
FROM MECHANICAL ROOM 120B TO ALL ROOMS IN BOZEMAN HEALTH'S TENANT SPACE
EXTENT OF FIRE SUPPRESSION SYSTEM
FEC
FEC
BOZEMAN HEALTH'S
TENANT SPACE
(NOT IN SCOPE)
BEHAVIORAL HEALTH
TENANT SPACE
Occupancy Load Legend
ACCESSORY STORAGE
AREAS, MECHANICAL
ASSEMBLY,
UNCONCENTRATED
BUSINESS
INPATIENT SLEEPING
AREAS
INPATIENT TREATMENT
AREAS
KITCHENS,
COMMERCIAL
LOCKER ROOM
NOT IN SCOPE
NOTE: HARD CONCRETE SURFACES AT ENTRANCES AND SIDE WALKS AT SUPPROUNDING OF BUILDING, SEE CIVIL PLANS
426 SF
CLINIC
STATION
128
84 SF
MEDS
127
90 SF
WORK AREA
128A
EXIT DOOR
7
34" 170
116.1
F.E. ACCESS = 43 FTF.E. ACCESS = 50 FTP
A
T
H O
F T
R
A
V
EL
= 63 F
T
62' -6"
14 sec
4 OCC
176 SF
R-4
EGRESS PATH AND DIRECTION
1 HOUR RATED WALL
EXIT SIGN
FIRE EXTINGUISHER CABINET (FEC). FIRE EXTINGUISHER, MULTIPURPOSE DRY
CHEMICAL TYPE: UL-RATED 4-A:60-B:C, 10-LB NOMINAL CAPACITY. NOTE: MAXIMUM
TRAVEL DISTANCE TO ANY FIRE EXTINGUISHER SHALL NOT EXCEED 75' PER IFC 505.1
AND NFPA 10.
AREA
EGRESS PATH
xxx
xx xx
OCCUPANT LOAD
NUMBER OF EXITS REQUIRED
NUMBER OF OCCUPANTS
xxxxx xx
EXIT WIDTH
OCCUPANTS ALLOWED
ROOM
DOOR
AREA
OCCUPANCY TYPE
NUMBER OF OCCUPANTS
X
XX OCC
XXX
X
EGRESS LEGEND
SCOPE OF WORK IN BOZEMAN HEALTH'S TENANT SPACE SHOWN SHADED:
1. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE EXISTING CONDITIONS AND VISIT THE SITE OF
WORK TO FULLY INFORM THEMSELVES OF ALL EXISTING CONDITIONS, FACILITIES, RESTRICTIONS AND
OTHER MATTERS WHICH CAN AFFECT THE WORK, IN TIMELINE, QUALITY OR COST THEREOF; FAILURE
OR OMISSION OF ANY CONTRACTOR TO VISIT THE SITE AND ACQUAINT THEMSELVES WITH THE
EXISTING CONDITIONS, SHALL IN NO WAY RELIEVE THEM FROM ANY OBLIGATION WITH RESPECT TO
THEIR CONTRACT AND NO EXTRA TIME OR COMPENSATION WILL BE ALLOWED BY REASON OF ANY
THING OR MATTER CONCERNING WHICH THE CONTRACTOR COULD HAVE FULLY INFORMED
THEMSELVES PRIOR TO BIDDING. GENERAL CONTRACTOR SHALL COORDINATE ALL ASPECTS OF THE
FIRE SUPPRESSION INSTALLATION IN BOZEMAN HEALTH'S TENANT SPACE.
2. EXTEND FIRE SUPPRESSION SYSTEM TO EVERY ROOM AS REQUIRED BY NFPA 13-2021 FOR A FULLY
SPRINKLERED BUILDING.
3. SEAL ALL PENETRATIONS FROM MECHANICAL ROOM 120A TO BOZEMAN HEALTH'S TENATN SPACE AT
FIRE RATED DIMISING WALL.
4. COORDINATE INFECTION PREVENTION MEASURES WITH BOZEMAN HEALTH OPERATIONS DEPARTMENT
PRIOR TO COMMENCEMENT OF ANY WORK IN TENANT SPACE. PROVIDE SCHEDULE OF WORK TO ALLOW
COORDINATION WITH WORKING STAFF.
5. REMOVE AND REPLACE ACOUSTICAL CEILING TILES AS REQUIRED TO INSTALL NEW MAIN AND
SECONDARY FIRE SUPPRESSION LINES.
6. REPLACE CONSTRUCTION DAMAGED CEILING TILES IN WORK AREAS.
7. REPLACE CEILING TILES BY END OF SHIFT TO MAINTAIN SAFE FINISH SPACE ENVELOPE; CONTACT
BOZEMAN HEALTH REPRESENTATIVE IF THIS CANNOT BE AVOIDED FOR FURTHER DIRECTIONS.
FIRE SUPPRESSION SCOPE OF WORK
issue date
project #
phasesheet projectownerrevision dateaddress
PERMIT SET8/29/2022 5:33:48 PMG1.1.1
08/29/2022LEVEL 1 CODE PLAN22006.00
PERMIT SETSPANISH PEAKSCONNECTIONS HEALTH SOLUTIONS120 19TH AVE. SUITE HBOZEMAN, MONTANA 597181/8" = 1'-0"13 LEVEL 1 CODE PLAN
OCCUPANT LOAD FACTOR
NAME
OCCUPANCY
TYPE
FUNCTION OF
SPACE AREA
OCCUPANT
LOAD FACTOR
OCCUPANT
LOAD
ACCESSORY STORAGE AREAS, MECHANICAL B LAUNDRY/MECH/IT 292 SF 300 SF 1
ACCESSORY STORAGE AREAS, MECHANICAL R-4 STORAGE 86 SF 300 SF 1
ASSEMBLY, UNCONCENTRATED B WAITING 21 SF 15 SF 2
ASSEMBLY, UNCONCENTRATED B WAITING 36 SF 15 SF 3
BUSINESS B CONSULT 109 SF 240 SF 1
BUSINESS B CONSULT 104 SF 240 SF 1
BUSINESS R-4 NURSES' STATION 608 SF 150 SF 5
BUSINESS R-4 LAB 62 SF 150 SF 1
INPATIENT SLEEPING AREAS R-4 PATIENT ROOM 165 SF 120 SF 2
INPATIENT SLEEPING AREAS R-4 PATIENT ROOM 165 SF 120 SF 2
INPATIENT SLEEPING AREAS R-4 PATIENT ROOM 162 SF 120 SF 2
INPATIENT SLEEPING AREAS R-4 INVOLUNARY PATIENT 82 SF 240 SF 1
INPATIENT SLEEPING AREAS R-4 PATIENT ROOM 191 SF 120 SF 2
INPATIENT SLEEPING AREAS R-4 INVOLUNARY PATIENT 81 SF 240 SF 1
INPATIENT TREATMENT AREAS R-4 CONSULTANT 94 SF 240 SF 1
KITCHENS, COMMERCIAL B CATERING/FOOD
PREP
163 SF 200 SF 1
LOCKER ROOM R-4 BREAK ROOM 176 SF 50 SF 4
TOTAL OCCUPANTS 31