HomeMy WebLinkAbout003 G1.0.1 CODE SUMMARYAPPLICABLE CODES AND ORDINANCES SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE BUILDING OCCUPANCY DATA FIRE AND SMOKE PROTECTION FEATURES BUILDING CONSTRUCTION PLUMBING CALCULATIONS FIRE PROTECTION SYSTEMS BUILDING EXITING - EGRESS ENERGY CODE - BUILDING ENVELOPE 2021 INTERNATIONAL BUILDING CODE (IBC) 2021 INTERNATIONAL EXISTING BUILDING CODE 2021 INTERNATIONAL ENERGY CONSERVATION CODE 2018 INTERNATIONAL FIRE CODE (IFC) 2021 INTERNATIONAL MECHANICAL CODE (IMC) 2021 INTERNATIONAL FUEL GAS CODE (IFGC) 2021 UNIFORM PLUMBING CODE 2020 NATIONAL ELECTRICAL CODE 2017 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES (ICC/ANSI 117.1) INCLUDES ALL CONDITIONED BUILDING AREAS INCLUDING MECHANICAL SHAFTS, ELEVATOR SHAFTS, AND STAIRWELLS B OCCUPANCY (NOT IN SCOPE) = 2368 SF R-4 OCCUPANCY (CHANGE FROM B) = 4819 SF TOTAL BUILDING SQUARE FOOTAGE = 7187 SF BUSINESS GROUP B (PER IBC 304.1) RESIDENTIAL GROUP R-4 (PER IBC 310.5) GENERAL BUILDING HEIGHTS AND AREAS CONSTRUCTION TYPE: 5B, FULLY SPRINKLERED TYPE X REQUIRED FIRE RESISTANCE PER TABLE 601: PRIMARY STRUCTURAL FRAME:0 HR BEARING WALLS EXTERIOR:0 HR INTERIOR:0 HR NONBEARING WALLS AND PARTITIONS PER TABLE 602: EXTERIOR:0 HR NONBEARING WALLS AND PARTITIONS: INTERIOR:0 HR FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS: 0 HR ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS:0 HR SEPARATION DISTANCES PER TABLE 705.5: FIRE SEPARATION DISTANCE, TYPE 5B, OCCUPANCY R-4 FIRE DISTANCE OCCUPANCY R-4 X<5' 1 HR 5' < X < 10 1 HR 10 < X < 30 0 HR X > 30 0 HR VERTICAL SEPARATION OF OPENINGS (PER SECTION 705.8.5) THIS SECTION SHALL NOT APPLY TO BUILDINGS THAT ARE THREE STORIES OF LESS ABOVE GRADE PLANE. FIRE WALL FIRE-RESISTANCE RATINGS (PER TABLE 706.4) N/A FIRE BARRIERS (PER SECTION 707) N/A FIRE PARTITIONS (PER SECTION 708) N/A SHAFT ENCLOSURES (PER SECTION 713) N/A ELEVATOR LOBBY (PER SECTION 713.14) N/A OPENING PROTECTIVES (PER SECTION 716) EXIT ENCLOSURE DOORS: 1 1/2 HOUR SHAFT ACCESS AT 2 HOUR WALLS: 1 1/2 HOUR SHAFT ACCESS AT 1 HOUR WALLS: 1 HOUR DOORS IN OTHER FIRE BARRIERS: 3/4 HOUR FIRE DOORS SHALL BE SELF-CLOSING OR AUTOMATIC CLOSING OCCUPANCY TYPE OCCUPANT LOAD EMPLOYEES AND VISITORS IN HOSPITALS AND NURSING HOMES CUSTODIAL CARE FACILITIES TOTAL: 19 PERSONS (9 MEN + 10 WOMEN) 10 PERSONS (5 MEN + 5 WOMEN) 29 PERSONS 14 MEN, 15 WOMEN WATER CLOSET LAVATORY MEN WOMEN DRINKING FOUNTAIN TOTAL PROVIDED: RATIO WATER CLOSETRATIO RATIOOCCUPANCY GROUP CUSTODIAL CARE 1 1 1 11:10 1:10 1:100 2 PER 2021 IECC TABLE C402.2: INSULATION ENTIRELY ABOVE DECKROOFS METAL FRAMEDWALLS, ABOVE GRADE BELOW- GRADE WALLWALLS, BELOW GRADE UNHEATED SLABSSLAB- ON- GRADE FLOORS SWINGING OPAQUE DOORS REQUIRED PROVIDED ROLL- UP OR SLIDING MONTANA - CLIMATE ZONE 6B R-30ci R-13 + R-10ci R-15ci R-20 FOR 24" BELOW U-0.37 R-4.75 EXISTING EXISTING EXISTING, R-15ci AT NEW FOUNDATION WALL EXISTING EXISTING, U-0.37 AT NEW DOORS N/A BUILDING ELEMENT FIXED FENESTRATION OPERABLE FENESTRATION ENTRANCE DOORS U-0.34; SHGC-0.38 U-0.42; SHGC-0.34 U-0.63; SHGC-0.34 U-0.33 MIN; GLAZING SHGC 0.27 MIN N/A U-0.33 MIN; GLAZING SHGC 0.27 MIN OCCUPANT LOAD (PER TABLE 1004.1.2) SEE EGRESS PLANS FOR OCCUPANCY TYPE AND OCCUPANT LOAD PER AREA BASED ON TABLE 1004.1.2 MEANS OF EGRESS WIDTH (PER SECTION 1005) STAIRWAYS: 0.3 INCHES PER OCCUPANT (EXCEPTION: IF BUILDING IS SPRINKLERED, APPLY .02 INCHES PER OCCUPANT) OTHER COMPONENTS: 0.2 PER OCCUPANT (EXCEPTION: IF BUILDING IS SPRINKLERED, APPLY .15 INCHES PER OCCUPANT) EGRESS ILLUMINATION (PER SECTION 1008) EMERGENCY EGRESS LIGHTING TO BE A MINIMUM OF 1 FOOT CANDLE AT WALKING SURFACE FOR A MINIMUM DURATION OF 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR. EXIT DOOR REQUIREMENTS (PER SECTION 1010) SINGLE LEAF MINIMUM CLEAR WIDTH = 32" PER 1010.1.2.1 DOORS SHALL SWING IN DIRECTION OF EGRESS TRAVEL WHERE SERVING A ROOM/ OR AREA CONTAINING AN OCCUPANT LOAD OF 50 OR MORE PERSONS. STAIRWAYS (PER SECTION 1011) N/A EXIT SIGNS (PER SECTION 1013) ALL EXIT AND EXIT ACCESS DOORS SHALL BE MARKED BY AN APPROVED EXIT SIGN READILY VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL. EXIT ACCESS TRAVEL DISTANCE (PER SECTION 1017) SPRINKLERED BUIDING: 250' CORRIDORS (PER SECTION 1020) EXCEPTION 2: A FIRE RESISTANCE RATING IS NOT REQUIRD FOR CORRDIRS CONTAINED WITHIN A DWELLING UNIT OR SLEEPING UNIT IN AN OCCUPANCY IN GROUPS I-1 OR R, IN BUILDING EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1 OR 903.3.1.2 ARE NOT REQUIRED TO BE RATED. MINIMUM WIDTH = 44" / DEAD ENDS (OCCUPANCY B, = 50' MAX DEAD ENDS (OCCUPANCY R-4) = 20' MAX EXIT PASSAGEWAYS (PER SECTION 1024) PER 402.8.6.1 EXIT PASSAGEWAYS: WHERE EXIT PASSAGEWAYS PROVIDE A SECONDARY MEANS OF EGRESS FROM A TENANT SPACE, DOORWAYS TO THE EXIT PASSAGEWAY SHALL BE PROTECTED BY A 1-HOUR FIRE DOOR ASSEMBLIES THAT ARE SELF OR AUTOMATIC CLOSING BY SMOKE DETECTION IN ACCORDANCE WITH SECTION 716.5.9.3 AUTOMATIC FIRE SPRINKLERS (PER SECTION 903) BUILDING SHALL BE FULLY SPRINKLERED. REFER TO 402.5 FOR PROVISIONS WITH A COVERED MALL BUILDING. PORTABLE FIRE EXTINGUISHERS (PER SECTION 906) SHALL BE PROVIDED IN OCCUPANCIES AND LOCATIONS AS REQUIRED BY THE FIRE CODE. CLASS A FIRE EXTINGUISHERS TO BE PROVIDED AT 150' SEPARATION DISTANCE. FIRE ALARM AND DETECTION (PER SECTION 907) PER 402.7.4 WHERE THE TOTAL FLOOR AREA IS GREATER THAN 50,000 SF WITHIN A COVERED MALL BUILDING, AN EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM SHALL BE PROVIDED IN ACCORDANCE WITH SECTION 907.5.2.2 EMERGENCY RESPONDER SAFETY FEATURES (PER SECTION 914.2 AND 402.7.5) ROOMS OR AREAS CONTAINING CONTROLS FOR AIR CONDITIONING SYSTEMS, AUTOMATIC FIRE-EXTINGUISHING SYSTEMS, AUTOMATIC SPRINKLER SYSTEMS OR OTHER DETECTION, SUPPRESSION OR CONTROL ELEMENTS SHALL BE IDENTIFIED FOR USE BY THE FIRE DEPARTMENT. APPROVED SIGNS REQUIRED TO IDENTIFY FIRE PROTECTION EQUIPMENT AND EQUIPMENT LOCATION SHALL BE CONSTRUCTED OF DURABLE MATERIALS, PERMANENTLY INSTALLED AND READILY VISIBLE. ACCESSIBILITY SECTION 1103 SCOPING REQUIREMENTS - 1103.1 WHERE REQUIRED. SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS AND SPACES, TEMPORARY OR PERMANENT, SHALL BE ACCESSIBLE TO PERSONS WITH PHYSICAL DISABILITIES. EXCEPTIONS: 1103.2.2 EMPLOYEE WORK AREAS. SPACES AND ELEMENTS WITHIN EMPLOYEE WORK AREAS SHALL ONLY BE REQUIRED TO COMPLY WITH SECTION 907.5.2.3.2, 1009, AND 1104.3.1 AND SHALL BE DESIGNED AND CONSTRUCTION SO THAT INDIVIDUALS WITH DISABILITIES CAN APPROACH, ENTER, AND EXIT THE WORK AREAS. 1103.2.7 LIMITED ACCESS SPACES. NONOCCUPIABLE SPACES ACCESSED ONLY BY LADDERS, CATWALKS, CRAWLSPACES, FREIGHT ELEVATORS OR VERY NARROW PASSAGEWAYS ARE NOT REQUIRED TO BE ACCESSIBLE. 1103.2.9 EQUIPMENT SPACES. SPACES FREQUENTED ONLY BY PERSONNEL FOR MAINTENANCE, REPAIR OR MONITORING OF EQUIPMENT ARE NOT REQUIRED TO BE ACCESSIBLE. 2203.2.14 WALK IN COOLERS AND FREEZERS. WALK IN COOLERS AND FREEZERS INTENDED FOR EMPLOYEE USE ONLY ARE NOT REQUIRED TO BE ACCESSIBLE. SECTION 1104 ACCESSIBLE ROUTES - 1104.5 LOCATION. ACCESSIBLE ROUTES SHALL COINCIDE WITH OR BE LOCATED IN THE SAME AREA AS A GENERAL CIRCULATION PATH. WHERE THE CIRCULATION PATH IS INTERIOR, THE ACCESSIBLE ROUTE SHALL ALSO BE INTERIOR. WHERE ONLY ONE ACCESSIBLE ROUTE IS PROVIDED, THE ACCESSIBLE ROUTE SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, RESTROOMS, CLOSETS, OR SIMILAR SPACES. 1105.1 PUBLIC ENTRANCES. IN ADDITION TO ACCESSIBLE ENTRANCES REQUIRED BY SECTION 1105.1.1 THROUGH 1105.1.6, AT LEAST 60 PERCENT OF ALL PUBLIC ENTRANCES SHALL BE ACCESSIBLE. EXCEPTIONS:LOADING AND SERVICE ENTRANCES THAT ARE NOT THE ONLY ENTRANCE TO A TENANT SPACE. 1105.1.7 TENANT SPACES. AT LEAST ONE ACCESSIBLE ENTRANCE SHALL BE PROVIDED TO EACH TENANT. SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES - 1106.1 REQUIRED. WHERE PARKING IS PROVIDED, ACCESSIBLE PARKING SPACES SHALL BE PROVIDED IN COMPLIANCE WITH TABLE 1106.2, EXCEPT AS REQUIRED BY SECTION 1106.3 THROUGH 1106.5. 1106.7 LOCATION. ACCESSIBLE PARKING SPACES SHALL BE LOCATED ON THE SHORTEST ACCESSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE BUILDING ENTRANCE. SECTION 1109 SPECIAL OCCUPANCIES - 1109.2 ASSEMBLY AREA SEATING. A BUILDING, ROOM OR SPACE USED FOR ASSEMBLY PURPOSED WITH FIXED SEATING SHALL COMPLY WITH SECTION 1109.2.1 THROUGH 110.92.5. PER 1109.2.2.1 GENERAL SEATING. WHEELCHAIR SPACES SHALL BE PROVIDED IN ACCORDANCE WITH TABLE 1109.2.2.1. SECTION 1112 SIGNAGE - 1112.1 SIGNS. REQUIRED ACCESSIBLE ELEMENTS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY AT THE FOLLOWING LOCATIONS: ACCESSIBLE PARKING SPACES, PASSENGER LOADING ZONES, ROOMS, ENTRANCES, CHECK-OUT AISLES, FAMILY OR ASSISTED-USE TOILET AND BATHING ROOMS, AREAS OF REFUGE, AND EXTERIOR AREAS. IN ADDITIONAL 1110.2 DIRECTIONAL SIGNAGE. DIRECTIONAL SIGNAGE INDICATING THE ROUTE TO THE NEAREST LIKE ACCESSIBLE ELEMENT SHALL BE PROVIDED AT THE FOLLOWING LOCATIONS STATED IN 1110.2 AND INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY. 1112.5 VARIABLE MESSAGE SIGNS - TRANSPORTATION FACILITIES. WHERE PROVIDED IN TRANSPORTATION FACILITIES, VARIABLE MESSAGE SIGNS CONVEYING TRANSPORTATION-RELATED INFORMATION SHALL COMPLY WITH SECTION 1112.5 R-4 OCCUPANCY CLASSIFICATION TYPE OF CONSTRUCTION AREA / ALLOWABLE V-B 28000 R-4 NUMBER OF STORIES / ALLOWABLE PRIMARY OCCUPANCY CLASSIFICATION TYPE OF CONSTRUCTION BUILDING HEIGHT / ALLOWABLE V-B 3 60 PER IBC TABLES 504.3, 504.4 PER IBC TABLE 506.2 FIRE AND SMOKE PROTECTION FEATURES DUCTS AND AIR TRANSFER OPENINGS (PER SECTION 717) DUCTS THAT PENETRATE FIRE-RESISTANCE-RATE ASSEMBLIES AND ARE NOT REQUIRED BY THIS SECTION TO HAVE DAMPERS SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 714.2 THROUGH 714.3.3. DUCTS THAT PENETRATE HORIZONTAL ASSEMBLIES NOT REQUIRED TO BE CONTAINED WITHIN A SHAFT AND NOT REQUIRED BY THIS SECTION TO HAVE DAMPERS SHALL COMPLY WITH THE REQUIREMENTS OF SECTIONS 714.4 THROUGH 714.4.2.2 DUCTS THAT PENETRATE NONFIRE-RESISTANCE-RATED ASSEMBLIES. THE SPACE AROUND A DUCT PENETRATING A NONFIRE-RESISTANCE-RATED FLOOR ASSEMBLY SHALL COMPLY WITH SECTION 717.6.3. CONCEALED SPACES (PER SECTION 718) FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED IN COMBUSTIBLE CONCEALED LOCATIONS IN ACCORDANCE WITH SECTION 718. FIREBLOCKING SHALL COMPLY WITH SECTION 718.2. DRAFTSTOPPING IN FLOOR/CEILING SPACES AND ATTIC SPACES SHALL COMPLY WITH SECTION 718.3 AND 718.4, RESPECTIVELY. THE PERMITTED USE OF COMBUSTIBLE MATERIALS IN CONCEALED SPACES OF BUILDINGS OF TYPE I OR II CONSTRUCTION SHALL BE LIMITED TO THE APPLICATIONS INDICATED IN SECTION 718.5. BATHTUB / SHOWER RATIO 2 1:8 RATIO 1:10 LAVATORY 1 RATIO 1:10 2 2 2 3 2 BUSINESS GROUP B - NOT IN SCOPE. PROVIDE PENETRATIONS THROUGH DEMISING WALL. CAP PENETRATIONS FOR FUTURE FIRE SPRINKLER INSTALL. RESIDENTIAL GROUP R-4 - FULL TENANT IMPROVEMENT BUILDOUT WITH OCCUPANCY CHANGE FROM B TO R-4 AA(R-4) = AT+(NS x IF) = 28,000SF + (7,000SF x 0) = 28000SF 2021 INTERNATIONAL ENERGY CODE SUMMARIES AND REFERENCE SECTIONS BELOW ARE PROVIDED FOR CONVENIANCE ONLY . IT IS THE CONTRACTORS RESPONSIBILITY TO UNDERSTAND AND MEET THE REQUIREMENTS OF THE 2021 INTERNATIONAL ENERGY CODE C402.5 AIR LEAKAGE (MANDATORY) THE THERMAL ENVELOPE OF BUILDINGS SHALL COMPLY WITH SECTIONS C402.4.1 THROUGH C402.4.8 C402.5.1 AIR BARRIERS A CONTINUOUS AIR BARRIER SHALL BE PROVIDED THROUGHOUT THE BUILDING THERMAL ENVELOPE. C402.5.1.1 AIR BARRIER CONSTRUCTION 1. THE AIR BARRIER SHALL BE CONTINUOUS FOR ALL ASSEMBLIES THAT ARE THE THERMAL ENVELOPE OF THE BUILDING AND ACROSS THE JOINTS AND ASSEMBLIES. 2. AIR BARRIER JOINTS AND SEAMS SHALL BE SEALED, INCLUDING SEALING TRANSITIONS IN PLACES AND CHANGES IN MATERIALS. THE JOINTS AND SEALS SHALL BE SECURELY INSTALLED IN OR ON THE JOINT FOR ITS ENTIRE LENGTH SO AS NOT TO DISLODGE, LOOSEN OR OTHERWISE IMPAIR ITS ABILITY TO RESIST POSITIVE AND NEGATIVE PRESSURE FROM WIND, STACK EFFECT AND MECHANICAL VENTILATION. 3. PENETRATIONS OF THE AIR BARRIER SHALL BE CAULKED, GASKETED OR OTHERWISE SEALED IN A MANNER COMPATIBLE WITH THE CONSTRUCTION MATERIALS AND LOCATION. SEALING SHALL ALLOW FOR EXPANSION, CONTRACTION AND MECHANICAL VIBRATION. JOINTS AND SEAMS ASSOCIATED WITH PENETRATIONS SHALL BE SEALED IN THE SAME MANNER OR TAPED. SEALING MATERIALS SHALL BE SECURELY INSTALLED AROUND THE PENETRATION SO AS NOT TO DISLODGE, LOOSEN OR OTHERWISE IMPAIR THE PENETRATIONS’ ABILITY TO RESIST POSITIVE AND NEGATIVE PRESSURE FROM WIND, STACK EFFECT AND MECHANICAL VENTILATION. SEALING OF CONCEALED FIRE SPRINKLERS, WHERE REQUIRED, SHALL BE IN A MANNER THAT IS RECOMMENDED BY THE MANUFACTURER. CAULKING OR OTHER ADHESIVE SEALANTS SHALL NOT BE USED TO FILL VOIDS BETWEEN FIRE SPRINKLER COVER PLATES AND WALLS OR CEILINGS. 4. RECESSED LIGHTING FIXTURES SHALL COMPLY WITH SECTION C402.5.10. WHERE SIMILAR OBJECTS ARE INSTALLED THAT PENETRATE THE AIR BARRIER, PROVISIONS SHALL BE MADE TO MAINTAIN THE INTEGRITY OF THE AIR BARRIER. C402.5.1.4 ASSEMBLIES THE BUILDING THERMAL ENVELOPE SHALL BE TESTED AND THE AIR LEAKAGE RATE OF THE BUILDING ENVELOPE SHALL NOT EXCEED 0.40 cfm/ft² AT A PRESSURE DIFFERENTIAL OF 0.3 INCHES WATER GAUGE (2.0l/s*m² AT 75 Pa) IN ACCORDANCE WITH ASTM E779 OR AN EQUIVALENT METHOD APPROVED BY THE CODE OFFICIAL. C402.4.2 AIR BARRIER PENETRATIONS A CONTINUOUS AIR BARRIER SHALL BE PROVIDED THROUGHOUT THE BUILDING THERMAL ENVELOPE. PER MONTANA ARM 24.301.351 - MINIMUM REQUIRED PLUMBING FIXTURES 1:25 1:35 1:100EMPLOYEES AND VISITORS 1 1 11 -1:25 1 1:25 TOTAL REQUIRED 2 2 2 2 2 2 issue date project # phasesheet projectownerrevision dateaddress PERMIT SET8/29/2022 5:33:41 PMG1.0.1 08/29/2022CODE SUMMARY22006.00 PERMIT SETSPANISH PEAKSCONNECTIONS HEALTH SOLUTIONS120 19TH AVE. SUITE HBOZEMAN, MONTANA 59718OCCUPANT LOAD FACTOR NAME OCCUPANCY TYPE FUNCTION OF SPACE AREA OCCUPANT LOAD FACTOR OCCUPANT LOAD ACCESSORY STORAGE AREAS, MECHANICAL B LAUNDRY/MECH/IT 292 SF 300 SF 1 ACCESSORY STORAGE AREAS, MECHANICAL R-4 STORAGE 86 SF 300 SF 1 ASSEMBLY, UNCONCENTRATED B WAITING 21 SF 15 SF 2 ASSEMBLY, UNCONCENTRATED B WAITING 36 SF 15 SF 3 BUSINESS B CONSULT 109 SF 240 SF 1 BUSINESS B CONSULT 104 SF 240 SF 1 BUSINESS R-4 NURSES' STATION 608 SF 150 SF 5 BUSINESS R-4 LAB 62 SF 150 SF 1 INPATIENT SLEEPING AREAS R-4 PATIENT ROOM 165 SF 120 SF 2 INPATIENT SLEEPING AREAS R-4 PATIENT ROOM 165 SF 120 SF 2 INPATIENT SLEEPING AREAS R-4 PATIENT ROOM 162 SF 120 SF 2 INPATIENT SLEEPING AREAS R-4 INVOLUNARY PATIENT 82 SF 240 SF 1 INPATIENT SLEEPING AREAS R-4 PATIENT ROOM 191 SF 120 SF 2 INPATIENT SLEEPING AREAS R-4 INVOLUNARY PATIENT 81 SF 240 SF 1 INPATIENT TREATMENT AREAS R-4 CONSULTANT 94 SF 240 SF 1 KITCHENS, COMMERCIAL B CATERING/FOOD PREP 163 SF 200 SF 1 LOCKER ROOM R-4 BREAK ROOM 176 SF 50 SF 4 TOTAL OCCUPANTS 31 OCCUPANT LOAD