Loading...
HomeMy WebLinkAbout004 C0.1 CMP&ConstructionRtMap II ' LANTERN DRIVE I '� 10 1 tl 'll EXT'G CURB, GUTTER & CONSTRUCTED WITH 1 ! PAVEMENT. PROTECT NEXUS POINT I lel DURING CONSTRUCTION m ,1 r Ii (TYP) PROPERTY LINE Q j i jl II III m I I z � \ IQ III I o LANTERN DR. I - — —w— — 4 — -- —�E}� Ili————- SCALE -------------------- I I I� _ J I I I L .; i t I s•. `,L' I, I �1 L I �' iil� nes iiI-- �L Iii " I I. ..I easr � I I Q11 ,� II II Y 80' zz I Iii ill ® �� ill --- 0 as ® /1 ---i-°- n'OG3 i`d WATER AND SEWER 1 I 1 I ' ! ! ---- Moll,"�° I I Stuck Rd. s , Lp °rirr i CONSTRUCTED WITH PHASE 1. 1 I y 1 c - , � I,T TT -I ii4 ----® S19tH WIDENING PROTECT ----- --- 1 I I 1 1 CONSTRUCTED WITH 1 NEX III Baer bP b b4-- ---b41R isle Fti �il I f l I U$ POINT I T 1 --'--- I i I I F�F�jj11 If o � n�i'i ii ii ii i i > "°a - --_ -_ _ ------- I e ---- AE �J i _ . i I ; , l I O �ia6aai i i ' �i ' � '� f' 7 8i rT�,', i ��+- Idlq ,I I' I V �� Ue rIT rl \ 1 Q) 1 F-I i i dN� ii I s i ii li l 11 •V ,i\\\\� 1 1 I 1 I I Q U] 1 CONSTRUCTION Ro.e :Re xeisasr il" q- rs�eee ''i'(/] 'i� >vesss macs ) ,l I w 1 ROUTE I I f -- �- PHASE I PHASE I -® amensr----- iiI I `•cer,sca ii I I III iiLl ameaer �®.T a I ; Bennett 'il ------ LL -----_® -L_----- -� �i ---wr — eaar> �i'R �I'i eaex 1 1 I I � I �19/22 --=-- - - -------------- - --------- ----- -- - _`i —- - �- I - --.»�- -------- a i — �.� r- ® 1 I _ � — 1 DRAWN BY: CGB I ----------- r �- � ----- `�q'� ---------- 1--- ---�' � I I , I 1 REVIEWED BY:ATM E " E I' PHA�LINE arrrsa ,'T�m- - ---------- --- �i "zseaer - I " i r zaoeaar 4, I �L I M 1 PROJECT R:CCB rvrea I I I 1 / � PROJECT ENGINEER: �I PHASE LINE LOCATION DESIGNED BY:CGB I I I t I at.oca f II I I I I I i i iii�sq i if�l 'I I I/ 1 � � I I 1 JELL , v 9II a �. rro I 8 4 - I 11 �I 1 I W I 1 _a (1 I (1 __ s s- rsesa " PHI18E II b b 4 as PHASE II 1 b 8 a asr . 1 I 1 j U U 'ii IL L'i21i1i - "a i sameaer I n 'Liii -i-i I'� V T Iii -a rerrsa I I -----s.-- L-- L I I LJ 1 _ on ei_ fl I " j fl RI Z b4 b I aaever � Graf St. i�_'�_�i L. . . . .J 'I " ` V III F I I 1 T' �T i� PROTECT WETLANDS CONSTRUCTION. CONSTRUCTION U R ROUTE ` _- II Ini �ii'iT FT i- --- -I r�ri)i -i-�i I'll ,r------ii I I by ! ! s�yai I11iii I II _ d4 ' Ibo- WATER iLb4i �c�I1 1\If CONSTRUCTION ROUTE MAP CONSTRUCTED WITH PHASE 1_ i i � 5 s B PROECTDLCONS TIONli UI F'i� URIN C -- -- �J s11 i III wso�eaer I n----r�'i I7}!7// ,ice �• / —4 w -- l rrnes ti-- I 1 i PG 12' 12' b m U I II II I ♦ II � � —— — GRAF STREET — s —— Il u s ° F4 ----------------------- IFIr- --------------/- 2-W WIDE e' / a GATE O EXT'G CURB, GUTTER & 4 p q U PAVEMENT. PROTECT I DURING CONSTRUCTION I 12 i (TYP) I I I LEGEND RAILING M CONSTRUCTION MANAGEMENT PLAN —4771 MINOR CONTOUR (1") • FOUND MONUMENT AS NOTED W �1 N SCALE: 1"=W —4775 MAJOR CONTOUR (5') ® CONTROL POINT F ——-— PROPERTY UNE/ROW BENCHMARK CONSTRUCTION MANAGEMENT PLAN — — — EASEMENT LINE QS SEWER MANHOLE CORNERtin 1901 1. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO ANY AREAS OUTSIDE SUBJECT X FENCE o SEWER CLEANOUT POST RAIL POSTTOPE FABRICCHAINLINK A PROPERTY LINE IN NON-IMPROVED AREAS. DISTURBED AREAS OUTSIDE —S— SEWER MAIN Dd WATER VALVE a E.I C PROPERTY LINE TO BE RESTORED TO PRIOR CONDITION OR BETTER. — so — SEWER SERVICE FIRE HYDRANT Gq 0 °0 2. CONTRACTOR SHALL PROVIDE BARRICADES AND WARNING DEVICES TO ENSURE —w— WATER MAIN ® CURB STOP THE SAFETY OF THE PUBLIC AS WELL AS WORKERS. —WS— WATER SERVICE Q WATER WELL — FS FIRE SERVICE STREET SIGN r.4 d L>a 3. NO TRENCHES SHALL BE LEFT IN AN UNSAFE CONDITION. ALL TRENCHES ,� � Q N SHALL BE SECURELY BARRICADED, PLATED OR FILLED IN BEFORE THE END OF sD STORM MAIN e BOLLARD a Z O EACH WORK DAY. OPEN TRENCHES SHALL NOT BE LEFT UNATTENDED. — OP — LIGHT POLE OVERHEAD POWER 17'i Pa 4. CONTRACTOR SHALL MAINTAIN SWPPP AT ALL TIMES. F OVERHEAD TELEPHONE moo, POWER POLE < > 8' v b GAS W — — GUY ANCHOR UNDERGROUND GAS � (~ 5. CONTRACTOR SHALL KEEP SITE CLEAN OF DEBRIS THAT MAY BLOW AWAY. TEL O ELECTRICAL PEDESTAL UNDERGROUND PHONE - E UNDERGROUND ELECTRIC ©" ELECTRICAL METER 00 6. CONSTRUCTION RASH ENCLOSURE AND MATERIAL STORAGE AREA TO BE ® TELEPHONE PEDESTAL LOCATED BY CONTRACTOR. SEE TRASH ENCLOSURE DETAIL SHOWN ON —-— ROAD CENTERLINE CONSTRUCTION MANAGMENT PLAN SHEET. CURB &GUTTER ® GAS METER 7. 40 CY ROLL OFF CONTAINER MAY BE USED IN LIEU OF TRASH ENCLOSURE EDGE OF PAVEMENT ra GAS VALVE P SHEET BUT MATERIAL STORAGE AREA ENCLOURE MUST BE PROVIDED. — — — EDGE OF GRAVEL 0 TEST PIT Co. BOTTOM NOTE: A G PERC TEST SELF 8. EXCAVATED MATERIAL SHALL BE STOCKPILED IN A SAFE CONDITION AND EDGE OF CONCRETE RAIL SUPPORTED REMOVED FROM SITE AS SOON AS PRACTICAL. EDGE OF BUILDING - TREE CONIFER (SIZE AS NOTED) 1. CONTRACTOR MAY USE ROLL OFF FENCE 2131 GRAF — GAS— 3 TREE DECIDUOUS (SIZE AS NOTED) CONTAINER AT HIS DISCRETION. CNP 9. NO ACCESS IS ALLOWED DIRECTLY FROM SOUTH 19TH AVENUE. UNDERGROUND GAS o — UP DETAII. UNDERGROUND ELECTRIC 1 i PROJECT:18-116 �0 t CONSTRUCTION TRASH ENCLOSURE&MATERIAL STORAGE AREA D N.T.S. DATE:07/07/19 61