HomeMy WebLinkAbout016 Sht L2.1-Irrigation Plan Schedule & NotesOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPWWWWWWWWSPTELTEL
TELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELSSSSSSSSGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASWWEST BABCOCK STREETHUFFINE LANEACCESS DRIVEACCESS DRIVEBBBBBBBABBBBBPOCBFMBBARFBBAAA2"2"114"114"114"LB2"114"1"1"114"2"2"LBBBBBBBBBBBBBBBBPOINT OF CONNECTIONPOC IS EXISTING COPPER CITY WATER SERVICE LINE WITH STATICPRESSURE OF 90PSI OR GREATER, LOCATION APPROXIMATE. TAPLINE AND SET WATER METER. IMPLEMENT A PRESSURE REDUCINGVALVE. THIS SYSTEM IS DESIGNED FOR A 1" WATER METER WITH60PSI STATIC PRESSURE, 20GPM DESIGN CAPACITY AND MAXIMUMWORKING PRESSURE OF 40GPM.MGKKO20.01"4.25112"9.001"18.41"19.91"CM5.13112"POC, BACKFLOW ASSEMBLY, &CONTROLLER LOCATION SHOWNDIAGRAMMATIC FOR CLARITY.PLACE IN LAWN, SOUTH OFGARDEN BED.2"114"1"2"2"114"1.CONTRACTOR RESPONSIBLE FOR PROVIDING IRRIGATION AS-BUILTS TO OWNER AT COMPLETION OFINSTALLATION.2.CONTRACTOR RESPONSIBLE TO INFORM LANDSCAPE ARCHITECT OF ANY DISCREPANCIES ORCHANGES NEEDED TO THE IRRIGATION DESIGN. IF CONTRACTOR MAKES CHANGES TO THEIRRIGATION DESIGN WITHOUT NOTIFYING THE LANDSCAPE ARCHITECT, CONTRACTOR ASSUMESFULL RESPONSIBILITY OF THE IRRIGATION SYSTEM DESIGN AND FUNCTIONALITY.3.CONTRACTOR TO VERIFY STATIC PRESSURE IN THE FIELD PRIOR TO BIDDING AND CONSTRUCTION. INTHE EVENT OF A DISCREPANCY, CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT IN WRITING OFANY CHANGES NECESSARY TO PROVIDE THE REQUIRED OPERATIONAL PRESSURE AND FLOW. IFNOTIFICATION IS NOT RECEIVED, CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR SYSTEMOPERABILITY.4.PROVIDE PRESSURE REDUCING VALVE IF PRESSURE EXCEEDS 80 PSI. REDUCE TO 60PSI STATICPRESSURE.5.INSTALLED SYSTEM TO BE FULLY WINTERIZEABLE. CONTRACTOR TO PROVIDE OWNER'SREPRESENTATIVE WITH WINTERIZATION PLAN.6.CONTRACTOR SHALL COORDINATE PLANTING WITH IRRIGATION INSTALLATION.7.THE CONTRACTOR SHALL INSPECT THE SITE AND VERIFY CONDITIONS AND DIMENSIONS PRIOR TOCONSTRUCTION.8.IRRIGATION PLANS ARE SCHEMATIC REPRESENTATIONS ONLY. PLACE LINES IN A COMMON TRENCHWHENEVER POSSIBLE. FIELD ADJUST LINES TO AVOID CONFLICT WITH UTILITIES.9.IRRIGATION IS COORDINATED WITH THE PLANTING PLAN AND SITE IMPROVEMENTS AND ISDESIGNED WITH RECTANGULAR SPACING GIVING HEAD TO HEAD COVERAGE. COORDINATEIRRIGATION HEAD LAYOUT WITH NEW PLANT MATERIALS, LOCATE SPRAY HEADS 30" FROM BASEOF TREE. DO NOT ALTER HEAD LOCATION, PIPE LAYOUT, OR VALVE LOCATION WITHOUT WRITTENAPPROVAL FROM THE CONSTRUCTION MANAGER. NOTIFY OWNER'S REPRESENTATIVE IFDISCREPANCIES OCCUR BETWEEN THE PLANS AND FIELD CONDITIONS.10.ALL COMPONENTS OF IRRIGATION SYSTEM SHALL BE INSTALLED AND PROPERLY ADJUSTED TOPROVIDE ADEQUATE HEAD TO HEAD COVERAGE AND MINIMIZATION OF OVER SPRAY ONTO WALKS,BUILDINGS, PARKING AREAS, ETC.11.ALL PIPE SIZES INDICATED ARE MINIMUMS. CONTRACTOR MAY NOT DECREASE PIPE SIZE. LARGERPIPE SIZES MAY BE USED AT NO ADDITIONAL COST TO OWNER. PIPE SIZES INCREASE IN SIZEDOWNSTREAM OF NEXT SPRAY HEAD, AS SHOWN.12.INSTALL ALL IRRIGATION PIPE AND CONTROL WIRES IN MINIMUM 4" PVC SLEEVE BELOW ALL PAVEDSURFACES UNLESS OTHERWISE INDICATED ON THE PLANS. INSTALL SLEEVES PRIOR TOPLACEMENT OF PAVEMENTS AND PAVEMENT SUB-BASE. WHERE PAVEMENT EXISTS BORE ANDPLACE SLEEVES.13.COORDINATE IRRIGATION POINTS OF CONNECTION AND LOCATION OF AUTOMATIC CONTROL VALVESWITH PROJECT MANAGER. COORDINATE ALL WORK WITH OTHER TRADES, I.E. ELECTRICAL,MASONRY, ETC.14.CONTRACTOR TO PROGRAM AUTOMATIC CONTROLLER TO ALLOW FOR THE EQUIVALENT OF 1" OFWATER PER WEEK, OR PER SITE AND PLANTING NEEDS FOR BEST PLANT HEALTH.15.ALL PIPES SHALL BE TRENCHED. PROVIDE POSITIVE DRAINAGE OF MAINLINE. PLACE MANUALDRAIN AT LOW POINTS IN MAINLINE. IDENTIFY LOCATIONS ON AS-BUILTS.16.USE 45°. ELLS INSTEAD OF 90-DEG. ELLS ON ALL MAINLINES 2-1/2" AND LARGER. INSTALL CMUTHRUST BLOCKS AT ALL MAINLINE CHANGES IN DIRECTION.17.CONTRACTOR TO INSTALL CONTROLLER AND ACCESSORIES AS REQUIRED. CONTRACTOR TOFURNISH CONTROL WIRES FROM VALVES TO CONTROLLER. CONTRACTOR SHALL BE RESPONSIBLEFOR COORDINATING 110 VOLT SERVICE FROM EXISTING ELECTRICAL SERVICE AND CONNECTION TOCONTROLLER SERVICE.18.INSTALL ONE (1) ADDITIONAL RED CONTROL WIRE AND ONE (1) ADDITIONAL WHITE CONTROL WIREFROM CONTROLLER TO END OF MAINLINE.SYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYPSIHUNTER MP1000 PROS-06-PRS40-CVTURF ROTATOR, 6" POP-UP WITH CHECK VALVE, PRESSUREREGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY.M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC,O=OLIVE 360 ARC.340HUNTER MP2000 PROS-06-PRS40-CVTURF ROTATOR, 6" POP-UP WITH FACTORY INSTALLED CHECKVALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLEON PRS40 BODY. K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC210-270, R=RED 360 ARC.340HUNTER MP3000 PROS-06-PRS40-CVTURF ROTATOR, 6" POP-UP WITH FACTORY INSTALLED CHECKVALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLEON PRS40 BODY. B=BLUE ADJ ARC 90-210, Y=YELLOW ADJ ARC210-270, A=GRAY 360 ARC.3640HUNTER MP3500 PROS-06-PRS40-CVTURF ROTATOR, 6.0" POP-UP WITH FACTORY INSTALLED CHECKVALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLEON PRS40 BODY. LB=LIGHT BROWN ADJUSTABLE ARC, 90-210.240HUNTER RZWS-36-CV36" LONG RZWS WITH INSTALLED .25GPM OR .50GPM BUBBLEROPTIONS, CHECK VALVE, 1/2" SWING JOINT FOR CONNECTION TO1/2" PIPE.3640SYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYHUNTER ICZ-151-40 1-1/2"DRIP CONTROL ZONE KIT. 1-1/2" ICV GLOBE VALVE WITH 1" HY100FILTER SYSTEM. PRESSURE REGULATION: 40PSI. FLOW RANGE:20 GPM TO 60 GPM. 120 MESH STAINLESS STEEL SCREEN.1-1/2" INLET X DUAL 1" OUTLETS2AREA TO RECEIVE DRIP EMITTERSHUNTER HE-BPOINT SOURCE DRIP EMITTER WITH SELF PIERCING BARB. COLORCODED EMITTERS FOR FLOW RATES OF 0.5, 1.0, 2.0, 4.0, AND 6.0GPH. CAN BE INSERTED INTO 1/2" AND 3/4" TUBING AND HAVEPRESSURE COMPENSATING FROM 15-50 PSI. OPTIONALDIFFUSER CAP (HE) AVAILABLE.14,548 S.F.Emitter Notes:05HE-B emitters (2 assigned to each 1 gal. plant)10HE-B emitters (2 assigned to each 1.75" Cal. plant)05HE-B emitters (2 assigned to each 2 gal. plant)20HE-B emitters (2 assigned to each 2" Cal. plant)05HE-B emitters (2 assigned to each 4" plant)10HE-B emitters (2 assigned to each 5 gal. plant)20HE-B emitters (2 assigned to each 8` Ht. plant)20HE-B emitters (2 assigned to each 15 gal. plant)SYMBOLMANUFACTURER/MODEL/DESCRIPTIONQTYHUNTER PGV-101G 1"1" PLASTIC ELECTRIC REMOTE CONTROL VALVE, FORRESIDENTIAL/LIGHT COMMERCIAL USE. FEMALE NPTINLET/OUTLET. GLOBE CONFIGURATION, WITH FLOW CONTROL.5HUNTER HQ-44LRC 1"QUICK COUPLER VALVE, YELLOW RUBBER LOCKING COVER, REDBRASS AND STAINLESS STEEL, WITH 1" NPT INLET, 2-PIECE BODY.4LASCO FITTINGS TUBV-SC1", 1-1/2", 2", AND 3" PLASTIC FULL BLOCK TRUE UNION BALL VALVE.SHUT OFF/ISOLATION VALVE TO ELIMINATE WATER HAMMER.INSTALL SAME SIZE AS MAINLINE.1BUCKNER-SUPERIOR 3000 1-1/2"NORMALLY CLOSED BRASS MASTER VALVE THAT PROVIDESDIRTY WATER PROTECTION AND 3-WAY SOLENOID DESIGN.AVAILABLE IN 1", 1-1/4", 1-1/2", 2", 2-1/2" AND 3" SIZES.1FEBCO LF825Y 1-1/2"REDUCED PRESSURE BACKFLOW PREVENTER, LEAD FREE1HUNTER HCC-800-PP8 STATION OUTDOOR WI-FI ENABLED, FULL-FUNCTIONINGCONTROLLER WITH TOUCHSCREEN, COMMERCIAL USE. PLASTICPEDESTAL.1HUNTER WRF-CLIKRAIN/FREEZE SENSOR, INSTALL WITHIN 1000 FT OF CONTROLLER,IN LINE OF SIGHT. 22-28 VAC/VDC 100 MA POWER FROM TIMERTRANSFORMER. MOUNT AS NOTED. INCLUDES GUTTER MOUNT.1POINT OF CONNECTION 1 1/4"CITY WATER SERVICE1IRRIGATION LATERAL LINE: POLYETHYLENE PIPE SDR-70.0 L.F.IRRIGATION LATERAL LINE: POLYETHYLENE PIPE SDR-7 1"2,513 L.F.IRRIGATION LATERAL LINE: POLYETHYLENE PIPE SDR-7 1 1/4"145.0 L.F.IRRIGATION MAINLINE: PVC SCHEDULE 40 2"785.1 L.F.PIPE SLEEVE: PVC CLASS 200 SDR 21206.5 L.F.MLOKGRBYALB0.250.50MBFCRFPOCValve NumberValve FlowValve SizeValve Callout###"NUMBERMODELTYPEPRECIPSUNMONTUEWEDTHUFRISATIN./WEEKMIN./WEEKGAL./WEEKGAL./DAY1HUNTER PGV-101GTURF ROTARY0.3 in/h50 min50 min50 min0.751502,763921.12HUNTER PGV-101GTURF ROTARY0.34 in/h45 min45 min45 min0.751332,653884.43HUNTER ICZ-151-40AREA FOR DRIP EMITTERS0.12 in/h173 min173 min173 min15172,653884.24HUNTER PGV-101GTURF ROTARY0.57 in/h27 min27 min27 min0.75791,578525.95HUNTER PGV-101GTURF ROTARY0.59 in/h26 min26 min26 min0.75771,541513.66HUNTER ICZ-151-40AREA FOR DRIP EMITTERS0.15 in/h133 min133 min133 min13981,672557.57HUNTER PGV-101GBUBBLER1.08 in/h28 min28 min156504252TOTALS:3341483061483341481,41013,3644,539WATER CONSUMPTION ESTIMATES ARE BASED ON ASEASONAL 24-WEEK WATERING WINDOW, AND ARE LISTEDIN ANNUAL TOTALSACRE FEET BASED ON SYSTEM DESIGN13,364 GAL/.WEEK = 0.98 AC.FT.ACRE FEET BASED ON VEGETATION TYPE SQUARE FEETTURF: 13.304 S.F. = 0.61 AC.FT.SHRUBS & GROUND COVER: 14.548 S.F. = 0.67 AC.FT.TREES: 126SF = 0.01 AC.FT.TOTAL: 1.28 AC.FT.FLOW TOTALSArea for Drip Emitters:9.4Bubbler:9.0Turf Rotary:78.4Total:96.7 GPMFLOW AVAILABLE28.5 GPMArea for Drip Emitters:1 ValvesBubbler:1 ValvesTurf Rotary:3 ValvesTotal:5 ValvesGenerated:2022-07-29 10:22P.O.C. NUMBER: 01Water Source Information:City Water ServiceFLOW AVAILABLEPoint of Connection Size:1 1/4"Flow Available28.49 GPMPRESSURE AVAILABLEStatic Pressure at POC:60.00 PSIPressure Available:60.00 psiDESIGN ANALYSISMaximum Multi-valve Flow:20 GPMFlow Available at POC:28.49 GPMResidual Flow Available:8.49 GPMCritical Station:5 Design Pressure:40 PSI Friction Loss:2.05 PSI Fittings Loss:0.2 PSI Elevation Loss:0 PSI Loss through Valve:3.3 PSIPressure Req. at Critical Station:45.56 PSILoss for Fittings:0 PSILoss for Main Line:0.4 PSILoss for POC to Valve Elevation:0 PSILoss for Backflow:12.25 PSILoss for Master Valve:0.45 PSICritical Station Pressure at POC:58.66 PSIPressure Available:60 PSIResidual Pressure Available:1.34 PSISHEET No:JOB No:DATE:REVISIONS:LANDSCAPE ARCHITECTURE& LAND PLANNING109 E Oak St, Ste 1FBozeman, MT(406) 624-9111info@inContour.com ZZZ.inContour.comPREPARED FOR:inContour07/29/20222109 W Babcock, Bozeman, MT
Tidal Wave Auto Spa21290Madison Engineering895 Technology BlvdBozeman, MT 59718(406) 586-0262L2.1IRRIGATION PLAN, SCHEDULE & NOTESSTA
T
E
OFMONTANALANDSCAPEARCH
ITECTLICENSE
D LESSA R.RACOW274NORTH0102040'SCALE 1" = 20'-0"IRRIGATION PLAN1