Loading...
HomeMy WebLinkAbout008 Sht A902-Floor PlanA B D E F G H I J K LD.1 1 2 2.1 3 4 5 9G A201 1D A201 1G A201 1A A201 3A A302 7A A302 3C A302 3F A302 7F A302 10F A302 1A A301 9D A301 107 ELECTRICAL ROOM AREA B - 1F/A102AREA A - 1A/A102AREA B - 1F/A102AREA A - 1A/A102 106 EQUIPMENT ROOM 105 MECHANICAL ROOM 67.70 SF RR 102 ENTRY 103 WASH TUNNEL 101 OPERATOR 9C A302 ROOF LINE ABOVE. SHED ROOF LINE ABOVE. D.S. D.S. D.S.D.S. D.S. D.S. D.S. D.S. D.S. 7G A201 A200 4C 5G A201 DASHED LINE INDICATES EXTENT OF TRENCH EXPOSED COLUMN PAINTED WITH CORROSION RESISTANT PAINT, TYP. MR PANEL ON VAPOR BARRIER ON CMU DASHED LINE INDICATES ACCESSIBLE LANDING. COORDINATE GRADING WITH CIVIL TO ENSURE HARD-SCAPE TO PROVIDE ACCESS. COILING DOOR EXPOSED STEEL - PAINT w/CORROSION RESISTANT PAINT, TYP. DASHED LINE INDICATES EXTENT OF MR PANEL ON VAPOR BARRIER ON CMU, TYP. HIGH SPEED OVERHEAD DOOR AND COILING DOOR MR PANEL ON VAPOR BARRIER ON CMU HIGH SPEED OVERHEAD DOOR FD, TYP M N P Q R S 108 EXIT TUNNEL 9AA202A 4 A 2 0 2 9 E A 2 0 2 SECTIONAL DOORS COILING DOOR MR PANEL ON VAPOR BARRIER ON CMU D.S. D.S. D.S. NOTE: COVER ALL EXPOSED INTERIOR CMU FACES AT WASH TUNNEL, ENTRY AREA, EXIT AREA WITH MOISTURE RESISTANT PANELS. VERIFY THAT SECTIONAL OH DOORS STACK IN ENTRY AREA IN OPEN POSITION AS REQUIRED BASED ON CLEARANCES PRESENT. SECTIONAL DOORS: TAPER SLAB EDGE AT OH DOOR THRESHOLDS TO SLOPE AWAY FROM BUILDING. (TYPICAL). TAPER SLAB AT DOOR THRESHOLD 3/8" TO DIVERT DRAINAGE AWAY FROM OPERATOR ROOM COVER ALL EXPOSED INTERIOR WALLS AT WASH TUNNEL AND ENTRY AREA WITH MOISTURE RESISTANT PANELS. GENERAL NOTE FROM TIDAL WAVE AUTO SPA: THE OPERATOR'S POSITION IS ONLY SUITABLE FOR PERSON'S ABLE OF FULL AMBULATORY ABILITY AS IT REQUIRES REACHING AUTOMOVILE TOPS AND TRUCK BEDS. BASE CABINETS SEE 8A &10A/A200 TAPER SLAB AT DOOR THRESHOLD 3/8" TO DIVERT DRAINAGE AWAY FROM MECH. RM. TRENCH EQUIPMENT: SEE ENLARGED PLAN AND SECTION ON SHEET A104. LAYOUTS AS SHOWN ARE APPROXIMATE AND SHALL BE COORDINATED WITH THE CAR WASH EQUIPMENT VENDOR PRIOR TO START. STEEL COLUMNS. SEE STRUCTURAL DRAWINGS, TYPICAL. ELECTRICAL ROOM WALLS 1-HR MIN. UL U904 FLUSH SLAB TRANSITION D.S. TIRE SHINE PIT. SEE A312SLOPE SLOPESLOPESLOPESLOPESLOPESLOPESLOPEA602 8H A320 8E A320 G8 A320 9A A601 5A A320 1D A320 5E A320 5A A320 1A A320 8C A320 5C A602 10H A200 5A A602 8H A105 11G 4' - 0"4' - 0"4' - 0"4' - 0" 2 ' - 0 " BOLLARD HD HD 2' - 0"5' - 0" 3' - 6" 3' - 6" 2 A. REFER TO SHEET G002 AND G003 FOR ASSEMBLY SPECIFICATIONS B. REFER TO ELEVATIONS AND BUILDING SECTIONS FOR EXTERIOR WALL ASSEMBLIES. C. REFER TO ELEVATIONS, SECTIONS AND SCHEDULES FOR WINDOW/ STOREFRONT TYPES. D. REFER TO PLAN AND SCHEDULES FOR DOOR TYPES. E. REFER TO SHEET G010 FOR TYPICAL ACCESSIBILITY DETAILS. F. REFER TO SHEET A200 FOR EXTERIOR AND INTERIOR FINISHES. G. DO NOT SCALE ANY CRITICAL DIMENSIONS. H. EXTERIOR GRADES: ALL EXTERIOR GRADES TO SLOPE AWAY FROM BUILDING. NO POOLING OF WATER/DRAINAGE ALLOWED. I. EXTERIOR STOOPS: PROVIDE FROST PROTECTED STOOPS AT ALL EXTERIOR DOOR STOOPS. EXTEND TO FROST LINE TO PROTECT FROM HEAVE. J. HEATED EXTERIOR SLABS: PROVIDE HEATED EXTERIOR SLABS (SNOW MELT SYSTEM) AS INDICATED ON THE PLUMBING PLANS, PROVIDE 1" RIGID INSULATION BELOW SUCH SLAB AREAS AS RECOMMENDED BY THE SNOW MELT SYSTEM MFR. INSTALLATION OF SUCH SYSTEM SHALL BE IN ACCORDANCE WITH THE MFR'S INSTRUCTIONS AS PER CONDITIONS PRESENT. LAYOUT AND INSTALL SHALL ALLOW FOR SLAB MOVEMENT. SEE DETAIL 6F/A105. K. CAR WASH EQUIPMENT IS BY OTHERS. ANY EQUIPMENT LAYOUTS/DATA SHOWN ON THESE DRAWINGS IS APPROXIMATE ONLY AND SHALL BE COORDINATED WITH WASH EQUIPMENT VENDOR PRIOR TO START. COORDINATE ALL ROUGH-INS REQUIRED WITH SUCH VENDOR PRIOR TO START. L. REFER TO SLAB PLAN FOR FLOOR SLOPES AND TRENCH DETAILS. M. REFER TO DIMENSION PLAN FOR DIMENSIONS AND PLAN DETAILS. N. DIMENSIONS ARE TO CENTER LINE OF COLUMN AND FACE OF COLUMN UNLESS NOTED OTHERWISE. GENERAL NOTES - FLOOR PLAN DASHED LINE INDICATES EXTENT OF MR PANEL ON VAPOR BARRIER ON CMU FLOOR PLAN LEGEND INTERIOR CMU WALLS ARE 10'-8" A.F.F. DRAWN BY: PROJ. NO: ADDRESS: SHEET SIZE:30" x 42" #DATE DESCRIPTION SHEET TITLE & NUMBER CHECKED BY: PROJECT INFORMATION Copyright 2021 PROJECT REVISIONS ISSUED: REVISED: SEAL ARCHITECT CLIENT CONSULTANT STRUCTURAL M.E.P. PROJECT CIVIL A 1 1 B C D E F G H J 2 3 4 5 6 7 8 9 10 11 2 3 4 5 6 7 8 9 10 11 A B C D E F G H J 12 127/25/2022 2:38:54 PMA101 FLOOR PLAN MLW 21039 2102 W. BABCOCK STREET BOZEMAN, MT 59718 3/8/22 TIDAL WAVE THORSON BAKER + ASSOCIATES 2055 READING ROAD, SUITE 280 CINCINNATI, OH 45202 513.579.8200 KLH ENGINEERS 1538 ALEXANDRIA PIKE STE 11 FORT THOMAS, KY 41075 614.603.2662 TIDAL WAVE AUTO SPA 2102 W. BABCOCK STREET BOZEMAN, MT 59718 NEW POTATO CREEK HOLDINGS, LLC 124 E. THOMPSON STREET TOMASTON, GA 30286 REZTARK DESIGN STUDIO, LLC 601 MAIN STREET, SUITE 200 CINCINNATI, OH 45202 513.233.3333 REZTARK DESIGN STUDIO, LLC (UNDER SEPARATE OWNER CONTRACT) MADISON ENGINEERING BOZEMAN, MT 59718 460.586.0262 IMR AUTO SPA 3/16" = 1'-0"A101 1A OVERALL FLOOR PLAN 2 07-22-22 Revision 2