HomeMy WebLinkAbout008 Sht A902-Floor PlanA B D E F G H I J K LD.1
1
2
2.1
3
4
5
9G
A201
1D
A201
1G
A201
1A
A201
3A
A302
7A
A302
3C
A302
3F
A302
7F
A302
10F
A302
1A
A301
9D
A301
107
ELECTRICAL
ROOM AREA B - 1F/A102AREA A - 1A/A102AREA B - 1F/A102AREA A - 1A/A102
106
EQUIPMENT
ROOM
105
MECHANICAL
ROOM
67.70 SF
RR
102
ENTRY
103
WASH
TUNNEL
101
OPERATOR
9C
A302
ROOF LINE ABOVE.
SHED ROOF
LINE ABOVE.
D.S.
D.S.
D.S.D.S.
D.S.
D.S.
D.S.
D.S.
D.S.
7G
A201
A200
4C
5G
A201
DASHED LINE INDICATES
EXTENT OF TRENCH
EXPOSED COLUMN PAINTED
WITH CORROSION RESISTANT
PAINT, TYP.
MR PANEL ON
VAPOR BARRIER
ON CMU
DASHED LINE INDICATES
ACCESSIBLE LANDING. COORDINATE
GRADING WITH CIVIL TO ENSURE
HARD-SCAPE TO PROVIDE ACCESS.
COILING DOOR
EXPOSED STEEL - PAINT
w/CORROSION RESISTANT
PAINT, TYP.
DASHED LINE INDICATES
EXTENT OF MR PANEL ON
VAPOR BARRIER ON CMU, TYP.
HIGH SPEED OVERHEAD
DOOR AND COILING DOOR
MR PANEL ON
VAPOR BARRIER
ON CMU
HIGH SPEED
OVERHEAD DOOR
FD, TYP
M N
P
Q
R
S
108
EXIT
TUNNEL
9AA202A 4
A 2 0 2
9 E
A 2 0 2
SECTIONAL
DOORS
COILING DOOR
MR PANEL ON
VAPOR BARRIER
ON CMU
D.S.
D.S.
D.S.
NOTE:
COVER ALL EXPOSED INTERIOR
CMU FACES AT WASH TUNNEL,
ENTRY AREA, EXIT AREA WITH
MOISTURE RESISTANT PANELS.
VERIFY THAT SECTIONAL OH DOORS
STACK IN ENTRY AREA IN OPEN
POSITION AS REQUIRED BASED ON
CLEARANCES PRESENT.
SECTIONAL DOORS:
TAPER SLAB EDGE AT OH
DOOR THRESHOLDS TO
SLOPE AWAY FROM
BUILDING. (TYPICAL).
TAPER SLAB AT DOOR
THRESHOLD 3/8" TO DIVERT
DRAINAGE AWAY FROM
OPERATOR ROOM
COVER ALL EXPOSED INTERIOR
WALLS AT WASH TUNNEL AND
ENTRY AREA WITH MOISTURE
RESISTANT PANELS.
GENERAL NOTE FROM TIDAL WAVE AUTO SPA:
THE OPERATOR'S POSITION IS ONLY SUITABLE
FOR PERSON'S ABLE OF FULL AMBULATORY
ABILITY AS IT REQUIRES REACHING
AUTOMOVILE TOPS AND TRUCK BEDS.
BASE CABINETS
SEE 8A &10A/A200
TAPER SLAB AT DOOR
THRESHOLD 3/8" TO
DIVERT DRAINAGE AWAY
FROM MECH. RM.
TRENCH EQUIPMENT: SEE ENLARGED PLAN
AND SECTION ON SHEET A104. LAYOUTS AS
SHOWN ARE APPROXIMATE AND SHALL BE
COORDINATED WITH THE CAR WASH
EQUIPMENT VENDOR PRIOR TO START.
STEEL COLUMNS. SEE
STRUCTURAL DRAWINGS, TYPICAL.
ELECTRICAL ROOM
WALLS 1-HR MIN. UL U904
FLUSH SLAB TRANSITION
D.S.
TIRE SHINE PIT.
SEE A312SLOPE
SLOPESLOPESLOPESLOPESLOPESLOPESLOPEA602
8H
A320
8E
A320
G8
A320
9A
A601
5A
A320
1D
A320
5E
A320
5A
A320
1A
A320
8C
A320
5C
A602
10H
A200
5A
A602
8H
A105
11G
4'
-
0"4'
- 0"4'
-
0"4'
-
0"
2 ' - 0 "
BOLLARD
HD HD 2' - 0"5' - 0"
3' - 6"
3' - 6"
2
A. REFER TO SHEET G002 AND G003 FOR ASSEMBLY SPECIFICATIONS
B. REFER TO ELEVATIONS AND BUILDING SECTIONS FOR EXTERIOR WALL ASSEMBLIES.
C. REFER TO ELEVATIONS, SECTIONS AND SCHEDULES FOR WINDOW/ STOREFRONT TYPES.
D. REFER TO PLAN AND SCHEDULES FOR DOOR TYPES.
E. REFER TO SHEET G010 FOR TYPICAL ACCESSIBILITY DETAILS.
F. REFER TO SHEET A200 FOR EXTERIOR AND INTERIOR FINISHES.
G. DO NOT SCALE ANY CRITICAL DIMENSIONS.
H. EXTERIOR GRADES: ALL EXTERIOR GRADES TO SLOPE AWAY FROM BUILDING. NO POOLING
OF WATER/DRAINAGE ALLOWED.
I. EXTERIOR STOOPS: PROVIDE FROST PROTECTED STOOPS AT ALL EXTERIOR DOOR STOOPS.
EXTEND TO FROST LINE TO PROTECT FROM HEAVE.
J. HEATED EXTERIOR SLABS: PROVIDE HEATED EXTERIOR SLABS (SNOW MELT SYSTEM) AS
INDICATED ON THE PLUMBING PLANS, PROVIDE 1" RIGID INSULATION BELOW SUCH SLAB
AREAS AS RECOMMENDED BY THE SNOW MELT SYSTEM MFR. INSTALLATION OF SUCH
SYSTEM SHALL BE IN ACCORDANCE WITH THE MFR'S INSTRUCTIONS AS PER CONDITIONS
PRESENT. LAYOUT AND INSTALL SHALL ALLOW FOR SLAB MOVEMENT. SEE DETAIL 6F/A105.
K. CAR WASH EQUIPMENT IS BY OTHERS. ANY EQUIPMENT LAYOUTS/DATA SHOWN ON THESE
DRAWINGS IS APPROXIMATE ONLY AND SHALL BE COORDINATED WITH WASH EQUIPMENT
VENDOR PRIOR TO START. COORDINATE ALL ROUGH-INS REQUIRED WITH SUCH VENDOR
PRIOR TO START.
L. REFER TO SLAB PLAN FOR FLOOR SLOPES AND TRENCH DETAILS.
M. REFER TO DIMENSION PLAN FOR DIMENSIONS AND PLAN DETAILS.
N. DIMENSIONS ARE TO CENTER LINE OF COLUMN AND FACE OF COLUMN UNLESS NOTED
OTHERWISE.
GENERAL NOTES - FLOOR PLAN
DASHED LINE INDICATES EXTENT OF MR PANEL ON VAPOR
BARRIER ON CMU
FLOOR PLAN LEGEND
INTERIOR CMU WALLS ARE 10'-8" A.F.F.
DRAWN BY:
PROJ. NO:
ADDRESS:
SHEET SIZE:30" x 42"
#DATE DESCRIPTION
SHEET TITLE & NUMBER
CHECKED BY:
PROJECT INFORMATION
Copyright 2021
PROJECT REVISIONS
ISSUED:
REVISED:
SEAL
ARCHITECT
CLIENT
CONSULTANT
STRUCTURAL
M.E.P.
PROJECT
CIVIL
A
1
1
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11
2 3 4 5 6 7 8 9 10 11
A
B
C
D
E
F
G
H
J
12
127/25/2022 2:38:54 PMA101
FLOOR PLAN
MLW
21039
2102 W. BABCOCK STREET
BOZEMAN, MT 59718
3/8/22
TIDAL WAVE
THORSON BAKER + ASSOCIATES
2055 READING ROAD, SUITE 280
CINCINNATI, OH 45202
513.579.8200
KLH ENGINEERS
1538 ALEXANDRIA PIKE STE 11
FORT THOMAS, KY 41075
614.603.2662
TIDAL WAVE AUTO SPA
2102 W. BABCOCK STREET
BOZEMAN, MT 59718
NEW POTATO CREEK HOLDINGS, LLC
124 E. THOMPSON STREET
TOMASTON, GA 30286
REZTARK DESIGN STUDIO, LLC
601 MAIN STREET, SUITE 200
CINCINNATI, OH 45202
513.233.3333
REZTARK DESIGN STUDIO, LLC
(UNDER SEPARATE OWNER CONTRACT)
MADISON ENGINEERING
BOZEMAN, MT 59718
460.586.0262
IMR
AUTO SPA
3/16" = 1'-0"A101
1A OVERALL FLOOR PLAN
2 07-22-22 Revision 2