HomeMy WebLinkAbout024 Water Reclaim System Detail TYPICAL LAYOUT TANK#1 TANK#2 TAN K#3 TANK#4 ERS-100e 14 � � 17 TANKS 8 TYPICAL 1,500 GAL.PRECAST CONCRETE 5 TANK#1-1A UNDERFLOW-1B PRIMARY SETTLEMENT b TANK#2-SECONDARY SETTLEMENT W./BAFFLE Nlyv 0 TANK#3-PROCESSTANK 12 TANK#4-OIL AND WATER SEPARATOR PER MUNICIPAL 1A 26 SPECIFICATIONS 1B L A 13 a GE MECHANICAL g 7 UNDERGROUND PLUMBING ROOM C 4 1-2"SCH 80 PVC PIPE-UNDERFLOW DISCHARGE-TO TANK 1A 3 2-6"SCH 40 PVC PIPE-EXTERNAL CROSSOVER-FROM TANK 1 B TO TANK 2A 3-TWO 6"SCH 40 PVC PIPES-CENTER TRENCH-TO TANK 16 4-4"OR 6"SCH 40 PVC PIPE-OVERFLOW FROM TANK 2B TO TANK 3 5-6"SCH 40 PVC PIPE-EXTERNAL CROSSOVER-FROM 15 WALL TANK 2B TO TANK 3 6-3"SCH 80 PVC PIPE-FILTER PUMP SUCTION LINE- V FROM WASH FROM TANK 3*SHOULD HAVE SLIGHT FALL TO RISER. ENTRANCE,16" INSTALL 90*AS HIGH AS POSSIBLE ON RISER TO BELOW ANGLE ALLOW FOR EASY MAINTENANCE.NO DEEPER THEN IRON 2'FROM FINISH GRADE* EXIT_ 7-3"SCH 80 PVC PIPE-SPARE SUCTION LINE-FROM g TANK 3*COMPLETE PLUMBING ON SPARE SUCTION LINE. UNION&FOOT VALVE SAME AS PRIMARY(6). CENTER TRENCH SHOULD HAVE SLIGHT FALL TO RISER. INSTALL900 AS HIGH AS POSSIBLE ON RISER TO ALLOW FOR EASY MAINTENANCE.* 8-4"OR 6"SCH 40 PVC PIPE-AQUAPREP DISCHARGE- SPLIT TO TANK 3 NOTES: ABOVE GROUND PLUMBING 9-4"OR 6"SCH 40 PVC PIPE-AQUAPREP DISCHARGE- -ACTUAL TANK DIMENSIONS MAY VARY. 10-2"PIPE-RECLAIM WATER OUTLET-FROM ERS TO CAR WASH EQUIPMENT SPLIT TO CENTER TRENCH -PLUMBING SHOULD BE PLACED AS SHOWN 11-2"PIPE-FRESH WATER INLET-FROM CITY WATER SOURCE TO ERS 12-6"SCH 40 PVC PIPE-INTERNAL CROSSOVER-FROM REGARDLESS OF WHAT TANKS ARE USED. 14-2"SCH 80 PVC PIPE-AQUAPREP DISCHARGE TEE'D W./BALL VALVES TANK 1A TO TANK 1 B -ALL PIPES MUST BE SET BELOW FROST LINE. 13-6"SCH 40 PVC PIPE-INTERNAL CROSSOVER-FROM -SUCTION LINES MUST BE SCH 80 PVC. UNDERGROUND ELECTRICAL TANK 2A TO TANK 2B -DO NOT INSTALL SCREENS ON FOOT VALVE. A-1"PVC CONDUIT-LOW WATER PROTECTION FLOAT SWITCH(FS-2)-TANK 3 15-6"SCH 40 PVC PIPE-TIRE SHINE DRAIN TO TANK 4 -CONSULT ENGINEER FOR ELEVATIONS. TO MECHANICAL ROOM 16-6"SCH 40 PVC PIPE-EXTERNAL CROSSOVER FROM -1 PIECE TANK IS REQUIRED B-1"PVC CONDUIT-FOR FUTURE USE-TANK 2B TO MECHANICAL ROOM TANK 3 TO TANK 4 -MATCH TANK ELEVATION AS SHOWN. 17-PIPE TO SANITARY SEWER ABOVE GROUND ELECTRICAL C-3 PHASE POWER IN L1-L2-L3 PENETRATIONS D-120 VAC CONTROL CIRCUIT FEED THROUGH CONCRETE 138 RISERS WITH 7" 24 26" 12" 3"TYP. 126 rSTEEL LIDS 12 AIR GAP 20" 6" 1"PVC CONDUIT FROM;INVI C +I JUNCTION BOX IN MANWAYO SIDE 12"_ _ 12" VIEYY 1 t 32" 8" a — I 15&16 8 4 32" 86"72" I 1 + TANK#1A TANK#1B 1 TANK#2A TANK#26 I TANK#3 TANK#4 B' 1/2"� 1/TYP. 1/2T PNK 1/2"�f 21' 8"1/2"JT FLOOR DROP DROP DROP 6"Typ. LOW WATER--] FOOT VALVE Thickness PROTECTION (IF FOOT VALVE IS FLOAT SWITCH RAISED,THE FLOAT (FS-2)-LOCATE SWITCH ALSO NEEDS 18"FROM TO BE RAISED) BOTTOM OF KEEP A 10"DISTANCE FLOAT WEIGHT BETWEEN THEM! NOT TO SCALE