HomeMy WebLinkAboutBillings Clinic Bozeman Ambulatory Destination Center, Ph 1 and Fire Line Infrastructure As-BuiltsVICINITY MAP106 East BabcockBozeman, Montana 59715406.522.9876sandersonstewart.comNORTHPROJECT NO:BILLINGS CLINICBILLINGS, MONTANA 59107P.O. BOX 37000BOZEMAN, MONTANAPREPARED FOR:BILLINGS CLINIC BOZEMAN CAMPUSPHASE I INFRASTRUCTURE IMPROVEMENTSCATCH CURBSPILL CURBTRANSITION FROM CATCHTAPER CURB HEAD 3'TO SPILL CURBGRADING PLANELECTRIC JUNCTION BOXEXISTING STORM DRAIN MANHOLEEXISTING CATCH BASINSIGNPOWER POLEEXISTING WATER VALVEEXISTING FIRE HYDRANTBOLLARDBUSHEXISTING CURB STOPFIRE DEPT. CONNECTIONFIBER OPTIC PEDESTALGAS METERGAS MANHOLEGAS VALVEGUYWIREIRRIGATION VALVEIRRIGATION BOXLIGHT POLEPOWER METERPOWER MANHOLEELECTRIC PEDESTALROOF DRAINSIGNAL POLEEXISTING SANITARY SEWER MANHOLESANITARY SEWER CLEAN OUTTELEPHONE BOXTELEPHONE MANHOLETELEPHONE PEDESTALTRANSFORMERCONIFEROUS TREEDECIDUOUS TREECOMMUNICATIONS MANHOLECOMMUNICATIONS PEDESTALWELLYARD HYDRANTDEMO AREAEW = FINISHED GRADE AT EDGE OF WALKTC = FINISHED GRADE AT TOP BACK OF CURBBC = FINISHED GRADE AT BUILDING CORNERTW = FINISHED GRADE AT TOP OF WALLAC = FINISHED GRADE AT ASPHALTEA = FINISHED GRADE AT EDGE OF ASPHALTEC = FINISHED GRADE AT EDGE OF CONCRETESDI = STORM DRAIN INLETSDMH = STORM DRAIN MANHOLEFL = FINISHED GRADE AT FLOWLINEFG = FINISHED GRADE EX = APPROXIMATE EXISTING ELEVATIONPOC = POINT ON CURVEEXISTING WATER REDUCERGAS WELLFOUND CORNER MONUMENT AS NOTEDSET CORNER MONUMENT, REBAR WITH CAPBENCHMARKSECTION QUARTER CORNERSECTION CORNERWTR = WATERPI = POINT OF INTERSECTIONPRC = POINT OF REVERSE CURVERT = RIGHTLT = LEFTSS = SANITARY SEWERPT = POINT OF TANGENCYSD = STORM DRAINGV = GATE VALVEBFV = BUTTERFLY VALVERED = REDUCERLF = LINEAL FOOTFT = FEETSSMH = SANITARY SEWER MANHOLEBVC = BEGIN VERTICAL CURVECS = CURB STOPEVC = END VERTICAL CURVEPVI = POINT OF VERTICAL INTERSECTIONLINETYPESABBREVIATIONSSYMBOLSPROPOSED CATCH BASINPROPOSED WATER REDUCERPROPOSED WATER VALVEPROPOSED FIRE HYDRANTPROPOSED CURB STOPPROPOSED SANITARY SEWER MANHOLEPROPOSED STORM DRAIN MANHOLEKEYNOTE CALL OUT(SEE KEYNOTE LEGEND)SRVC = SERVICE(TYP.) = TYPICALPC = POINT OF CURVATUREEXISTING MONUMENT BOXPROPOSED MONUMENT BOXGR = EXISTING GRADE AT GROUNDBRK = GRADE BREAKFIBER OPTICGAS PIPELINEOIL PIPELINEUNDERGROUND POWERSANITARY SEWERSTORM DRAINTELEPHONETELEVISION/CABLEWATERCONTOUROVERHEAD POWERFENCE - VINYLFENCE - BARBWIREFENCE - WOODCURB AND GUTTEREDGE OF ASPHALTEDGE OF GRAVELFENCE - CHAINLINK/WOVEN WIREEXISTINGPROPOSEDHP = HIGH POINT15063.02AS-BUILTSSITE90SHEETTITLEC1.0COVER SHEETC2.0EXISTING TOPOGRAPHY & DEMOLITION PLANC3.0OVERALL SITE PLANC4.0PLAN & PROFILE - STREET AC4.1PLAN & PROFILE - STREET AC4.2PLAN & PROFILE - STREET AC4.3PLAN & PROFILE - STREET BC4.4PLAN & PROFILE - WATER MAIN - EAST VALLEY CENTER ROADC4.5PLAN & PROFILE - WATER MAIN - NORTH 27TH AVENUEC4.6PLAN & PROFILE - SANITARY SEWER 1C4.7EAST VALLEY CENTER ROADC6.0DETAILSC6.1DETAILSC7.0SIGNAGE AND STRIPING - COMMONS BLVD & ROUNDABOUTC7.1SIGNAGE AND STRIPING - COMMONS BLVDC7.2SIGNAGE AND STRIPING - WARBLER WAYC7.3SIGNAGE AND STRIPING - EAST VALLEY CENTER DRIVEC7.4SIGNAGE AND STRIPING - N. 27TH AVEGENERAL NOTES:-ALL IMPROVEMENTS SHALL BE PERFORMED IN ACCORDANCE WITH MONTANA PUBLIC WORKS STANDARDSPECIFICATIONS 6TH EDITION, APRIL, 2010, AND THE CITY OF BOZEMAN STANDARD MODIFICATIONS,DATED MARCH 31, 2011 WITH ADDENDUM.-ANY EXISTING OR NEW VALVES WHICH CONTROL THE CITY OF BOZEMAN'S WATER SUPPLY SHALL BEOPERATED BY CITY OF BOZEMAN PERSONNEL ONLY.-CONTRACTOR SHALL FIELD VERIFY AND GRADE OF EXISTING CONNECTIONS.-THE CONTRACTOR SHALL NOTIFY THE WATER DEPARTMENT A MINIMUM OF 24-HOURS PRIOR TOBEGINNING ANY WORK.-EXISTING UNDERGROUND INSTALLATIONS & PRIVATE UTILITIES SHOWN ARE INDICATED ACCORDING TOTHE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THEACCURACY OF SUCH INFORMATION. SERVICE LINES (WATER, POWER, GAS, STORM, SEWER, TELEPHONE &TELEVISION) MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THE PLANS. STATE LAW REQUIRESCONTRACTOR TO CALL ALL UTILITY COMPANIES BEFORE EXCAVATION FOR EXACT LOCATIONS.-UNLESS OTHERWISE SPECIFIED, ALL CONSTRUCTION LAYOUT AND STAKING SHALL BE PERFORMED UNDERTHE RESPONSIBLE CHARGE OF A LAND SURVEYOR LICENSED IN THE STATE OF MONTANA AND BY A PARTYCHIEF OR ENGINEERING TECHNICIAN EXPERIENCED IN CONSTRUCTION LAYOUT AND STAKING TECHNIQUESAS ARE REQUIRED BY THE SPECIFIC TYPE OF WORK BEING PERFORMED.P:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_COVER_PROD.dwg, C1.0, 8/16/2022 1:06:00 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (24.00 x 36.00 Inches), 1:1
08/15/22
ZONEAGRICULTURESUBURBANZONE M-2ZONEAGRICULTURESUBURBANZONE B-2ZONE PLIZONE R-4CP#52CP#51CP#50CP#53PROJECT SURVEY CONTROLPoint #50515253Northing134845.53135164.94135463.41135757.35Easting373324.39372868.41372476.46372086.59Elevation4643.614641.274640.064638.06DescriptionCP /2" ACR SS CTL MONCP /2" ACR SS CTL MONCP /2" ACR SS CTL MONCP /2" ACR SS CTL MONPROJECT DATUM: THE BASIS OF BEARING FOR THIS SURVEY HAS BEENDERIVED FROM GPS OBSERVATIONS AND IS BASED ON A NAD 83,LAMBERT CONFORMAL CONIC, SINGLE PARALLEL, LOW DISTORTIONPROJECTION FOR THE CITY OF BOZEMAN; HAVING A POINT OF ORIGINAT 46°15'00" N LATITIUDE AND 111°15'00" W LONGITUDE WITH ASCALE FACTOR OF 1.000185. THE GRID TO GROUND COMBINED SCALEFACTOR IS 1.00000765; THE CONVERGENCE ANGLE IS 0°07'34".DISTANCES ARE INTERNATIONAL FEET (IFT). FOR THIS SURVEY GRIDDISTANCE IS ESSENTIALLY EQUAL TO GROUND DISTANCE.SURVEYED: 1/10/2019 BY: KSELECTRIC JUNCTION BOXTELEPHONESTORM DRAIN MANHOLECATCH BASINSIGNSANITARY SEWERSTORM DRAINPOWER POLEWATER VALVEFIRE HYDRANTFOUND CORNER MONUMENT AS NOTEDLEGENDGASPOWEROVERHEAD POWER LINETYPICALSET CORNER MONUMENT, REBAR WITH CAPBOLLARDBUSHCURB STOPFIRE DEPT. CONNECTIONGUYWIRESANITARY SEWER MANHOLESANITARY SEWER CLEAN OUTTELEPHONE PEDESTALTRANSFORMERCONIFEROUS TREEDECIDUOUS TREECOMMUNICATIONS BOXCOMMUNICATIONS PEDESTALEX. WELLEX. YARD HYDRANTFIBER OPTICWATEREXISTING GRADE CONTOURSDEMO AREA0100SCALE: 1:10020050100AS-BUILTSNORTH
FILE:
PROJECT NO:
CAD:
QUALITY ASSURANCE:
DRAWING HISTORY
DATE DESCRIPTION
EXISTING TOPOGRAPHY & DEMOLITION PLAN
BILLINGS CLINIC BOZEMAN CAMPUS
PHASE I INFRASTRUCTURE IMPROVEMENTS
BOZEMAN, MONTANAC2.0-
15063_02_EX_PROD.DWG
BG/LMH
06/03/20 PRELIM
07/02/20
09/04/20
02/02/21
04/29/21
06/29/21
07/16/21
REVIEW SUBMITTAL
CITY COMMENTS
SAN SEWER SRVC REVS
REVS THROUGH 04/29/21
REVS THROUGH 06/28/21
STREET REVS
08/06/21 CITY REVS FOR N 27TH AVE
15063.02GENERAL NOTES:-ALL IMPROVEMENTS SHALL BE PERFORMED IN ACCORDANCE WITH MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS 6TH EDITION, APRIL, 2010, AND THE CITY OF BOZEMAN STANDARD MODIFICATIONS, DATED MARCH 31, 2011 WITH ADDENDUM.-ANY EXISTING OR NEW VALVES WHICH CONTROL THE CITY OF BOZEMAN'S WATER SUPPLY SHALL BE OPERATED BY CITY OF BOZEMAN PERSONNEL ONLY.-CONTRACTOR SHALL FIELD VERIFY AND GRADE OF EXISTING CONNECTIONS.-THE CONTRACTOR SHALL NOTIFY THE WATER DEPARTMENT A MINIMUM OF 24-HOURS PRIOR TO BEGINNING ANY WORK.-EXISTING UNDERGROUND INSTALLATIONS & PRIVATE UTILITIES SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. SERVICE LINES(WATER, POWER, GAS, STORM, SEWER, TELEPHONE & TELEVISION) MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THE PLANS. STATE LAW REQUIRES CONTRACTOR TO CALL ALL UTILITY COMPANIES BEFORE EXCAVATION FOR EXACT LOCATIONS.-UNLESS OTHERWISE SPECIFIED, ALL CONSTRUCTION LAYOUT AND STAKING SHALL BE PERFORMED UNDER THE RESPONSIBLE CHARGE OF A LAND SURVEYOR LICENSED IN THE STATE OF MONTANA AND BY A PARTY CHIEF OR ENGINEERING TECHNICIANEXPERIENCED IN CONSTRUCTION LAYOUT AND STAKING TECHNIQUES AS ARE REQUIRED BY THE SPECIFIC TYPE OF WORK BEING PERFORMED.07/01/22 AS-BUILT RECORD DRAWINGS
P:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_EX_PROD.dwg, C2.1, 8/16/2022 1:06:18 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (24.00 x 36.00 Inches), 1:1
08/15/22
ZONEAGRICULTURESUBURBANZONE M-2ZONEAGRICULTURESUBURBANZONE B-2ZONE PLIZONE R-40100SCALE: 1" = 100'20050100AS-BUILTSNORTH
FILE:
PROJECT NO:
CAD:
QUALITY ASSURANCE:
DRAWING HISTORY
DATE DESCRIPTION
OVERALL SITE PLAN
BILLINGS CLINIC BOZEMAN CAMPUS
PHASE I INFRASTRUCTURE IMPROVEMENTS
BOZEMAN, MONTANAC3.0-
15063_02_OVERALL_PROD.DWG
BG/LMH
06/03/20 PRELIM
07/02/20
09/04/20
02/02/21
04/29/21
06/29/21
07/16/21
REVIEW SUBMITTAL
CITY COMMENTS
SAN SEWER SRVC REVS
REVS THROUGH 04/29/21
REVS THROUGH 06/28/21
STREET REVS
08/06/21 CITY REVS FOR N 27TH AVE
15063.02GENERAL NOTES:-ALL IMPROVEMENTS SHALL BE PERFORMED IN ACCORDANCE WITH MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS 6TH EDITION, APRIL, 2010, AND THE CITY OF BOZEMAN STANDARD MODIFICATIONS, DATEDMARCH 31, 2011 WITH ADDENDUM.-ANY EXISTING OR NEW VALVES WHICH CONTROL THE CITY OF BOZEMAN'S WATER SUPPLY SHALL BE OPERATED BY CITY OF BOZEMAN PERSONNEL ONLY.-CONTRACTOR SHALL FIELD VERIFY AND GRADE OF EXISTING CONNECTIONS.-THE CONTRACTOR SHALL NOTIFY THE WATER DEPARTMENT A MINIMUM OF 24-HOURS PRIOR TO BEGINNING ANY WORK.-EXISTING UNDERGROUND INSTALLATIONS & PRIVATE UTILITIES SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OFSUCH INFORMATION. SERVICE LINES (WATER, POWER, GAS, STORM, SEWER, TELEPHONE & TELEVISION) MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THE PLANS. STATE LAW REQUIRES CONTRACTOR TO CALL ALLUTILITY COMPANIES BEFORE EXCAVATION FOR EXACT LOCATIONS.-UNLESS OTHERWISE SPECIFIED, ALL CONSTRUCTION LAYOUT AND STAKING SHALL BE PERFORMED UNDER THE RESPONSIBLE CHARGE OF A LAND SURVEYOR LICENSED IN THE STATE OF MONTANA AND BY A PARTY CHIEFOR ENGINEERING TECHNICIAN EXPERIENCED IN CONSTRUCTION LAYOUT AND STAKING TECHNIQUES AS ARE REQUIRED BY THE SPECIFIC TYPE OF WORK BEING PERFORMED.AS-BUILT RECORD DRAWINGS07/01/22
P:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_OVERALL_PROD.dwg, C3.1, 8/16/2022 1:06:47 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (24.00 x 36.00 Inches), 1:1
08/15/22
VERT. : 1" = 5'HORIZ. : 1" = 30'PROFILEPLAN : 1" = 30'SCALENORTH30150SCALE:1:303060NOTE:-EXISTING UNDERGROUND INSTALLATIONS & PRIVATE UTILITIES SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THEENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. SERVICE LINES (WATER, POWER, GAS, STORM, SEWER,TELEPHONE & TELEVISION) MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THE PLANS. STATE LAW REQUIRES CONTRACTOR TO CALL ALL UTILITYCOMPANIES BEFORE EXCAVATION FOR EXACT LOCATIONS.-ALL IMPROVEMENTS SHALL BE PERFORMED IN ACCORDANCE WITH MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS 6TH EDITION, APRIL, 2010,AND THE CITY OF BOZEMAN STANDARD MODIFICATIONS, DATED MARCH 31, 2011 WITH ADDENDUM.-UNLESS OTHERWISE SPECIFIED, ALL CONSTRUCTION LAYOUT AND STAKING SHALL BE PERFORMED UNDER THE RESPONSIBLE CHARGE OF A LANDSURVEYOR LICENSED IN THE STATE OF MONTANA AND BY A PARTY CHIEF OR ENGINEERING TECHNICIAN EXPERIENCED IN CONSTRUCTION LAYOUT ANDSTAKING TECHNIQUES AS ARE REQUIRED BY THE SPECIFIC TYPE OF WORK BEING PERFORMED.AS-BUILTS
FILE:
PROJECT NO:
CAD:
QUALITY ASSURANCE:
DRAWING HISTORY
DATE DESCRIPTION
PLAN & PROFILE - STREET A
BILLINGS CLINIC BOZEMAN CAMPUS
PHASE I INFRASTRUCTURE IMPROVEMENTS
BOZEMAN, MONTANAC4.0-
15063_02_P-P_PROD.DWG
BG/LMH
06/03/20 PRELIM
07/02/20
09/04/20
02/02/21
04/29/21
06/29/21
07/16/21
REVIEW SUBMITTAL
CITY COMMENTS
SAN SEWER SRVC REVS
REVS THROUGH 04/29/21
REVS THROUGH 06/28/21
STREET REVS
08/06/21 CITY REVS FOR N 27TH AVE
15063.02
AS-BUILT RECORD DRAWINGS07/01/22
P:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_P-P_PROD.dwg, C4.0, 8/16/2022 1:07:48 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (24.00 x 36.00 Inches), 1:1
08/15/22
NORTH30150SCALE:1:303060NOTE:-EXISTING UNDERGROUND INSTALLATIONS & PRIVATE UTILITIES SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THEENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. SERVICE LINES (WATER, POWER, GAS, STORM, SEWER,TELEPHONE & TELEVISION) MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THE PLANS. STATE LAW REQUIRES CONTRACTOR TO CALL ALL UTILITYCOMPANIES BEFORE EXCAVATION FOR EXACT LOCATIONS.-ALL IMPROVEMENTS SHALL BE PERFORMED IN ACCORDANCE WITH MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS 6TH EDITION, APRIL, 2010,AND THE CITY OF BOZEMAN STANDARD MODIFICATIONS, DATED MARCH 31, 2011 WITH ADDENDUM.-UNLESS OTHERWISE SPECIFIED, ALL CONSTRUCTION LAYOUT AND STAKING SHALL BE PERFORMED UNDER THE RESPONSIBLE CHARGE OF A LANDSURVEYOR LICENSED IN THE STATE OF MONTANA AND BY A PARTY CHIEF OR ENGINEERING TECHNICIAN EXPERIENCED IN CONSTRUCTION LAYOUT ANDSTAKING TECHNIQUES AS ARE REQUIRED BY THE SPECIFIC TYPE OF WORK BEING PERFORMED.AS-BUILTS
FILE:
PROJECT NO:
CAD:
QUALITY ASSURANCE:
DRAWING HISTORY
DATE DESCRIPTION
PLAN & PROFILE - STREET A
BILLINGS CLINIC BOZEMAN CAMPUS
PHASE I INFRASTRUCTURE IMPROVEMENTS
BOZEMAN, MONTANAC4.1-
15063_02_P-P_PROD.DWG
BG/LMH
06/03/20 PRELIM
07/02/20
09/04/20
02/02/21
04/29/21
06/29/21
07/16/21
REVIEW SUBMITTAL
CITY COMMENTS
SAN SEWER SRVC REVS
REVS THROUGH 04/29/21
REVS THROUGH 06/28/21
STREET REVS
08/06/21 CITY REVS FOR N 27TH AVE
15063.02SCALEPLAN : 1" = 30'PROFILEHORIZ. : 1" = 30'VERT. : 1" = 5'AS-BUILT RECORD DRAWINGS07/01/22
P:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_P-P_PROD.dwg, C4.1, 8/16/2022 1:08:05 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (24.00 x 36.00 Inches), 1:1
08/15/22
VERT. : 1" = 5'HORIZ. : 1" = 30'PROFILEPLAN : 1" = 30'SCALENORTH30150SCALE:1:303060NOTE:-EXISTING UNDERGROUND INSTALLATIONS & PRIVATE UTILITIES SHOWN ARE INDICATED ACCORDING TO THE BESTINFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION.SERVICE LINES (WATER, POWER, GAS, STORM, SEWER, TELEPHONE & TELEVISION) MAY NOT BE STRAIGHT LINES OR ASINDICATED ON THE PLANS. STATE LAW REQUIRES CONTRACTOR TO CALL ALL UTILITY COMPANIES BEFORE EXCAVATION FOREXACT LOCATIONS.-ALL IMPROVEMENTS SHALL BE PERFORMED IN ACCORDANCE WITH MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS 6THEDITION, APRIL, 2010, AND THE CITY OF BOZEMAN STANDARD MODIFICATIONS, DATED MARCH 31, 2011 WITH ADDENDUM.-UNLESS OTHERWISE SPECIFIED, ALL CONSTRUCTION LAYOUT AND STAKING SHALL BE PERFORMED UNDER THE RESPONSIBLECHARGE OF A LAND SURVEYOR LICENSED IN THE STATE OF MONTANA AND BY A PARTY CHIEF OR ENGINEERING TECHNICIANEXPERIENCED IN CONSTRUCTION LAYOUT AND STAKING TECHNIQUES AS ARE REQUIRED BY THE SPECIFIC TYPE OF WORK BEINGPERFORMED.AS-BUILTS
FILE:
PROJECT NO:
CAD:
QUALITY ASSURANCE:
DRAWING HISTORY
DATE DESCRIPTION
PLAN & PROFILE - STREET A
BILLINGS CLINIC BOZEMAN CAMPUS
PHASE I INFRASTRUCTURE IMPROVEMENTS
BOZEMAN, MONTANAC4.2-
15063_02_P-P_PROD.DWG
BG/LMH
06/03/20 PRELIM
07/02/20
09/04/20
02/02/21
04/29/21
06/29/21
07/16/21
REVIEW SUBMITTAL
CITY COMMENTS
SAN SEWER SRVC REVS
REVS THROUGH 04/29/21
REVS THROUGH 06/28/21
STREET REVS
08/06/21 CITY REVS FOR N 27TH AVE
15063.02
AS-BUILT RECORD DRAWINGS07/01/22
P:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_P-P_PROD.dwg, C4.2, 8/16/2022 1:08:22 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (24.00 x 36.00 Inches), 1:1
08/15/22
VERT. : 1" = 5'HORIZ. : 1" = 30'PROFILEPLAN : 1" = 30'SCALENORTH30150SCALE:1:303060NOTE:-EXISTING UNDERGROUND INSTALLATIONS & PRIVATE UTILITIES SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THEENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. SERVICE LINES (WATER, POWER, GAS, STORM, SEWER,TELEPHONE & TELEVISION) MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THE PLANS. STATE LAW REQUIRES CONTRACTOR TO CALL ALL UTILITYCOMPANIES BEFORE EXCAVATION FOR EXACT LOCATIONS.-ALL IMPROVEMENTS SHALL BE PERFORMED IN ACCORDANCE WITH MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS 6TH EDITION, APRIL, 2010,AND THE CITY OF BOZEMAN STANDARD MODIFICATIONS, DATED MARCH 31, 2011 WITH ADDENDUM.-UNLESS OTHERWISE SPECIFIED, ALL CONSTRUCTION LAYOUT AND STAKING SHALL BE PERFORMED UNDER THE RESPONSIBLE CHARGE OF A LANDSURVEYOR LICENSED IN THE STATE OF MONTANA AND BY A PARTY CHIEF OR ENGINEERING TECHNICIAN EXPERIENCED IN CONSTRUCTION LAYOUT ANDSTAKING TECHNIQUES AS ARE REQUIRED BY THE SPECIFIC TYPE OF WORK BEING PERFORMED.AS-BUILTS
FILE:
PROJECT NO:
CAD:
QUALITY ASSURANCE:
DRAWING HISTORY
DATE DESCRIPTION
PLAN & PROFILE - STREET B
BILLINGS CLINIC BOZEMAN CAMPUS
PHASE I INFRASTRUCTURE IMPROVEMENTS
BOZEMAN, MONTANAC4.3-
15063_02_P-P_PROD.DWG
BG/LMH
06/03/20 PRELIM
07/02/20
09/04/20
02/02/21
04/29/21
06/29/21
07/16/21
REVIEW SUBMITTAL
CITY COMMENTS
SAN SEWER SRVC REVS
REVS THROUGH 04/29/21
REVS THROUGH 06/28/21
STREET REVS
08/06/21 CITY REVS FOR N 27TH AVE
15063.02
AS-BUILT RECORD DRAWINGS07/01/22
P:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_P-P_PROD.dwg, C4.3, 8/16/2022 1:08:38 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (24.00 x 36.00 Inches), 1:1
08/15/22
VERT. : 1" = 5'HORIZ. : 1" = 30'PROFILEPLAN : 1" = 30'SCALENORTH30150SCALE:1:30NOTE:-EXISTING UNDERGROUND INSTALLATIONS & PRIVATE UTILITIES SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THEENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. SERVICE LINES (WATER, POWER, GAS, STORM, SEWER,TELEPHONE & TELEVISION) MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THE PLANS. STATE LAW REQUIRES CONTRACTOR TO CALL ALL UTILITYCOMPANIES BEFORE EXCAVATION FOR EXACT LOCATIONS.-ALL IMPROVEMENTS SHALL BE PERFORMED IN ACCORDANCE WITH MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS 6TH EDITION, APRIL, 2010,AND THE CITY OF BOZEMAN STANDARD MODIFICATIONS, DATED MARCH 31, 2011 WITH ADDENDUM.-UNLESS OTHERWISE SPECIFIED, ALL CONSTRUCTION LAYOUT AND STAKING SHALL BE PERFORMED UNDER THE RESPONSIBLE CHARGE OF A LANDSURVEYOR LICENSED IN THE STATE OF MONTANA AND BY A PARTY CHIEF OR ENGINEERING TECHNICIAN EXPERIENCED IN CONSTRUCTION LAYOUT ANDSTAKING TECHNIQUES AS ARE REQUIRED BY THE SPECIFIC TYPE OF WORK BEING PERFORMED.3060AS-BUILTS
FILE:
PROJECT NO:
CAD:
QUALITY ASSURANCE:
DRAWING HISTORY
DATE DESCRIPTION
PLAN & PROFILE - WATER MAIN - EAST VALLEY CENTER ROAD
BILLINGS CLINIC BOZEMAN CAMPUS
PHASE I INFRASTRUCTURE IMPROVEMENTS
BOZEMAN, MONTANAC4.4-
15063_02_P-P_PROD.DWG
BG/LMH
06/03/20 PRELIM
07/02/20
09/04/20
02/02/21
04/29/21
06/29/21
07/16/21
REVIEW SUBMITTAL
CITY COMMENTS
SAN SEWER SRVC REVS
REVS THROUGH 04/29/21
REVS THROUGH 06/28/21
STREET REVS
08/06/21 CITY REVS FOR N 27TH AVE
15063.02
AS-BUILT RECORD DRAWINGS07/01/22
P:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_P-P_PROD.dwg, C4.4, 8/16/2022 1:08:54 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (24.00 x 36.00 Inches), 1:1
08/15/22
VERT. : 1" = 5'HORIZ. : 1" = 30'PROFILEPLAN : 1" = 30'SCALENORTH30150SCALE:1:303060NOTE:-EXISTING UNDERGROUND INSTALLATIONS & PRIVATE UTILITIES SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. SERVICE LINES (WATER, POWER, GAS,STORM, SEWER, TELEPHONE & TELEVISION) MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THE PLANS. STATE LAW REQUIRES CONTRACTOR TO CALL ALL UTILITY COMPANIES BEFORE EXCAVATION FOR EXACT LOCATIONS.-ALL IMPROVEMENTS SHALL BE PERFORMED IN ACCORDANCE WITH MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS 6TH EDITION, APRIL, 2010, AND THE CITY OF BOZEMAN STANDARD MODIFICATIONS, DATED MARCH 31, 2011 WITH ADDENDUM.-UNLESS OTHERWISE SPECIFIED, ALL CONSTRUCTION LAYOUT AND STAKING SHALL BE PERFORMED UNDER THE RESPONSIBLE CHARGE OF A LAND SURVEYOR LICENSED IN THE STATE OF MONTANA AND BY A PARTY CHIEF OR ENGINEERING TECHNICIAN EXPERIENCED IN CONSTRUCTIONLAYOUT AND STAKING TECHNIQUES AS ARE REQUIRED BY THE SPECIFIC TYPE OF WORK BEING PERFORMED.AS-BUILTS
FILE:
PROJECT NO:
CAD:
QUALITY ASSURANCE:
DRAWING HISTORY
DATE DESCRIPTION
PLAN & PROFILE - WATER MAIN - NORTH 27TH AVENUE
BILLINGS CLINIC BOZEMAN CAMPUS
PHASE I INFRASTRUCTURE IMPROVEMENTS
BOZEMAN, MONTANAC4.5-
15063_02_P-P_PROD.DWG
BG/LMH
06/03/20 PRELIM
07/02/20
09/04/20
02/02/21
04/29/21
06/29/21
07/16/21
REVIEW SUBMITTAL
CITY COMMENTS
SAN SEWER SRVC REVS
REVS THROUGH 04/29/21
REVS THROUGH 06/28/21
STREET REVS
08/06/21 CITY REVS FOR N 27TH AVE
15063.02
AS-BUILT RECORD DRAWINGS07/01/22
P:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_P-P_PROD.dwg, C4.5, 8/16/2022 1:09:10 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (24.00 x 36.00 Inches), 1:1
08/15/22
VERT. : 1" = 5'HORIZ. : 1" = 30'PROFILEPLAN : 1" = 30'SCALENOTE:-EXISTING UNDERGROUND INSTALLATIONS & PRIVATE UTILITIES SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THEENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. SERVICE LINES (WATER, POWER, GAS, STORM, SEWER,TELEPHONE & TELEVISION) MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THE PLANS. STATE LAW REQUIRES CONTRACTOR TO CALL ALL UTILITYCOMPANIES BEFORE EXCAVATION FOR EXACT LOCATIONS.-ALL IMPROVEMENTS SHALL BE PERFORMED IN ACCORDANCE WITH MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS 6TH EDITION, APRIL, 2010,AND THE CITY OF BOZEMAN STANDARD MODIFICATIONS, DATED MARCH 31, 2011 WITH ADDENDUM.-UNLESS OTHERWISE SPECIFIED, ALL CONSTRUCTION LAYOUT AND STAKING SHALL BE PERFORMED UNDER THE RESPONSIBLE CHARGE OF A LANDSURVEYOR LICENSED IN THE STATE OF MONTANA AND BY A PARTY CHIEF OR ENGINEERING TECHNICIAN EXPERIENCED IN CONSTRUCTION LAYOUT ANDSTAKING TECHNIQUES AS ARE REQUIRED BY THE SPECIFIC TYPE OF WORK BEING PERFORMED.AS-BUILTS
FILE:
PROJECT NO:
CAD:
QUALITY ASSURANCE:
DRAWING HISTORY
DATE DESCRIPTION
PLAN & PROFILE - SANITARY SEWER 1
BILLINGS CLINIC BOZEMAN CAMPUS
PHASE I INFRASTRUCTURE IMPROVEMENTS
BOZEMAN, MONTANAC4.6-
15063_02_P-P_PROD.DWG
BG/LMH
06/03/20 PRELIM
07/02/20
09/04/20
02/02/21
04/29/21
06/29/21
07/16/21
REVIEW SUBMITTAL
CITY COMMENTS
SAN SEWER SRVC REVS
REVS THROUGH 04/29/21
REVS THROUGH 06/28/21
STREET REVS
08/06/21 CITY REVS FOR N 27TH AVE
15063.0230150SCALE:1:303060NORTHAS-BUILT RECORD DRAWINGS07/01/22
P:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_P-P_PROD.dwg, C4.6, 8/16/2022 1:09:26 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (24.00 x 36.00 Inches), 1:1
08/15/22
AS-BUILTSNORTH FILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTIONLOT 2A-1, MINOR SUBDIVISION 221FEAST VALLEY CENTER ROADBILLINGS CLINIC BOZEMAN CAMPUSPHASE I INFRASTRUCTURE IMPROVEMENTSBOZEMAN, MONTANAC4.7 -15063_02_EAST VALLEY_PROD.DWGBG/LMH06/03/20PRELIM07/02/2009/04/2002/02/2104/29/2106/29/2107/16/21REVIEW SUBMITTALCITY COMMENTSSAN SEWER SRVC REVSREVS THROUGH 04/29/21REVS THROUGH 06/28/21STREET REVS08/06/21CITY REVS FOR N 27TH AVE15063.020 30
SCALE: 1" = 30'
601530 AS-BUILT RECORD DRAWINGS07/01/22P:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_EAST VALLEY_PROD.dwg, C4.7, 8/16/2022 1:10:23 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (36.00 x 24.00 Inches), 1:108/15/22
MEDIAN SECTION WITH CONCRETE CAP AS-BUILTSFILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTIONLOT 2A-1, MINOR SUBDIVISION 221FDETAILSBILLINGS CLINIC BOZEMAN CAMPUSPHASE I INFRASTRUCTURE IMPROVEMENTSBOZEMAN, MONTANAC6.0 -15063_02_DETAILS.DWGBG/LMH06/03/20PRELIM07/02/2009/04/2002/02/2104/29/2106/29/2107/16/21REVIEW SUBMITTALCITY COMMENTSSAN SEWER SRVC REVSREVS THROUGH 04/29/21REVS THROUGH 06/28/21STREET REVS08/06/21CITY REVS FOR N 27TH AVE15063.02AS-BUILT RECORD DRAWINGS07/01/22P:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_DETAILS.dwg, C6.0, 8/16/2022 1:10:40 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (36.00 x 24.00 Inches), 1:108/15/22
AS-BUILTSFILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTIONLOT 2A-1, MINOR SUBDIVISION 221FDETAILSBILLINGS CLINIC BOZEMAN CAMPUSPHASE I INFRASTRUCTURE IMPROVEMENTSBOZEMAN, MONTANAC6.1 -15063_02_DETAILS.DWGBG/LMH06/03/20PRELIM07/02/2009/04/2002/02/2104/29/2106/29/2107/16/21REVIEW SUBMITTALCITY COMMENTSSAN SEWER SRVC REVSREVS THROUGH 04/29/21REVS THROUGH 06/28/21STREET REVS08/06/21CITY REVS FOR N 27TH AVE15063.02AS-BUILT RECORD DRAWINGS07/01/22P:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_DETAILS.dwg, C6.1, 8/16/2022 1:10:41 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (36.00 x 24.00 Inches), 1:108/15/22
0 20
SCALE: 1" = 20'
401020
AS-BUILTSNORTH
FILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTION15063.02CITY REVS FOR N 27TH AVE08/06/21STREET REVSREVS THROUGH 06/28/21REVS THROUGH 04/29/21SAN SEWER SRVC REVSCITY COMMENTSREVIEW SUBMITTAL07/16/2106/29/2104/29/2102/02/2109/04/2007/02/20PRELIM06/03/20BG/LMH15063_02_S-S_PROD.DWG-C7.0BOZEMAN, MONTANAPHASE I INFRASTRUCTURE IMPROVEMENTSBILLINGS CLINIC BOZEMAN CAMPUSSIGNAGE AND STRIPING - COMMONS BLVD & ROUNDABOUTSHARKS TOOTH MARKINGS DETAIL
WHITE FLEXIBLE
SURFACE-MOUNT DELINEATOR
YELLOW FLEXIBLE
SURFACE-MOUNT DELINEATOR AS-BUILT RECORD DRAWINGS07/01/22P:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_S-S_PROD.dwg, C7.0, 8/16/2022 1:11:05 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (36.00 x 24.00 Inches), 1:108/15/22
0 20
SCALE: 1" = 20'
401020
AS-BUILTSNORTH
FILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTION15063.02CITY REVS FOR N 27TH AVE08/06/21STREET REVSREVS THROUGH 06/28/21REVS THROUGH 04/29/21SAN SEWER SRVC REVSCITY COMMENTSREVIEW SUBMITTAL07/16/2106/29/2104/29/2102/02/2109/04/2007/02/20PRELIM06/03/20BG/LMH15063_02_S-S_PROD.DWG-C7.1BOZEMAN, MONTANAPHASE I INFRASTRUCTURE IMPROVEMENTSBILLINGS CLINIC BOZEMAN CAMPUSSIGNAGE AND STRIPING - COMMONS BLVDNORTH AS-BUILT RECORD DRAWINGS07/01/22P:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_S-S_PROD.dwg, C7.1, 8/16/2022 1:11:14 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (36.00 x 24.00 Inches), 1:108/15/22
0 20
SCALE: 1" = 20'
401020
AS-BUILTSNORTH
FILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTION15063.02CITY REVS FOR N 27TH AVE08/06/21STREET REVSREVS THROUGH 06/28/21REVS THROUGH 04/29/21SAN SEWER SRVC REVSCITY COMMENTSREVIEW SUBMITTAL07/16/2106/29/2104/29/2102/02/2109/04/2007/02/20PRELIM06/03/20BG/LMH15063_02_S-S_PROD.DWG-C7.2BOZEMAN, MONTANAPHASE I INFRASTRUCTURE IMPROVEMENTSBILLINGS CLINIC BOZEMAN CAMPUSSIGNAGE AND STRIPING - WARBLER WAY07/01/22AS-BUILT RECORD DRAWINGSP:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_S-S_PROD.dwg, C7.2, 8/16/2022 1:11:20 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (36.00 x 24.00 Inches), 1:108/15/22
0 20
SCALE: 1" = 20'
401020 AS-BUILTSNORTH FILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTION15063.02CITY REVS FOR N 27TH AVE08/06/21STREET REVSREVS THROUGH 06/28/21REVS THROUGH 04/29/21SAN SEWER SRVC REVSCITY COMMENTSREVIEW SUBMITTAL07/16/2106/29/2104/29/2102/02/2109/04/2007/02/20PRELIM06/03/20BG/LMH15063_02_S-S_PROD.DWG-C7.3BOZEMAN, MONTANAPHASE I INFRASTRUCTURE IMPROVEMENTSBILLINGS CLINIC BOZEMAN CAMPUSSIGNAGE AND STRIPING - EAST VALLEY CENTER DRIVEEAST VALLEY STRIPING07/01/22AS-BUILT RECORD DRAWINGS06/06/22P:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_S-S_PROD.dwg, C7.3, 8/16/2022 1:11:24 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (36.00 x 24.00 Inches), 1:108/15/22
0 20
SCALE: 1" = 20'
401020
NORTH
FILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTION15063.02CITY REVS FOR N 27TH AVE08/06/21STREET REVSREVS THROUGH 06/28/21REVS THROUGH 04/29/21SAN SEWER SRVC REVSCITY COMMENTSREVIEW SUBMITTAL07/16/2106/29/2104/29/2102/02/2109/04/2007/02/20PRELIM06/03/20BG/LMH15063_02_S-S_PROD.DWG-C7.4BOZEMAN, MONTANAPHASE I INFRASTRUCTURE IMPROVEMENTSBILLINGS CLINIC BOZEMAN CAMPUSSIGNAGE AND STRIPING - N. 27TH AVE0 20
SCALE: 1" = 20'
401020
NORTH
SHARKS TOOTH MARKINGS DETAIL AS-BUILT RECORD DRAWINGSAS-BUILTS07/01/22P:\15063_02_Minor_Sub_221_Blgs_Clinic_Boz_Off-Site_Imp_PM\CADD_C3D\PRODUCTION_DWG\ON-SITE\NEW ON-SITE 051220\15063_02_S-S_PROD.dwg, C7.4, 8/16/2022 1:11:31 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (36.00 x 24.00 Inches), 1:108/15/22
VICINITY MAP
1300 North Transtech Way Billings, Montana 59102 406.656.5255 sandersonstewart.com
NORTH
PROJECT NO:
BILLINGS CLINIC
BILLINGS, MONTANA 59101
PO BOX 3700BOZEMAN, MONTANA
OWNER/APPLICANT:
BILLINGS CLINIC BOZEMAN ADC
LOT 2A-1, MINOR SUBDIVISION
TOWNSHIP 1S., RANGE 5E., SECTION 26 P.M.M.
15063.07 AS-BUILTS
PROJECT TEAM:
CIVIL ENGINEERING:
SANDERSON STEWART
PERSPECTIVE OF MAIN ENTRY/COVERED DROPOFF
FIRE LINE AND HYDRANT MAIN INFRASTRUCTURE PLANS
INFRASTRUCTURE PLAN SHEET LIST
Sheet Number Sheet Title
C0.0 COVER
C1.1 SITE PLAN
C2.1 FIRE LINE PNP
C2.2 HYDRANT MAIN PNP
C2.3 FIRE LINE DETAILS
P:\15063_07_BC_Bozeman_Ambulatory_Dest_Center_Expansion_Site_Civil\CADD_C3D\PRODUCTION_DWG\15063.07_FIRE_LINE_COVER.dwg, C0.0 COVER, 8/17/2022 2:25:09 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (36.00 x 24.00 Inches), 1:108/15/22
AS-BUILTSNORTH
0 20
SCALE: 1" = 20'
401020 FILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTIONTOWNSHIP 1S., RANGE 5E., SECTION 26 P.M.M.SITE PLANBILLINGS CLINIC BOZEMAN ADCLOT 2A-1, MINOR SUBDIVISIONBOZEMAN, MONTANAC1.1 -15063.07_FIRE_LINE_SITE_PROD.DWGLMH08/01/22AS-BUILT RECORD DRAWINGS--------------15063.07FIRE LINE AND HYDRANT INFRASTRUCTUREP:\15063_07_BC_Bozeman_Ambulatory_Dest_Center_Expansion_Site_Civil\CADD_C3D\PRODUCTION_DWG\15063.07_FIRE_LINE_SITE_PROD.dwg, C1.1 SITE PLAN, 8/17/2022 2:25:24 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (36.00 x 24.00 Inches), 1:108/15/22
AS-BUILTSNORTH VERTICAL SCALE: 1"=4'
20 10 0
HORIZONTAL SCALE:1" = 20'
20 40
FILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTIONFIRE LINE AND HYDRANT INFRASTRUCTURETOWNSHIP 1S., RANGE 5E., SECTION 26 P.M.M.FIRE LINE PNPBILLINGS CLINIC BOZEMAN ADCLOT 2A-1, MINOR SUBDIVISIONBOZEMAN, MONTANAC2.1 -15063_07_PNP_WATER.DWGLMH08/01/22AS-BUILT RECORD DRAWINGS--------------15063.07*TABLE 10.10.2.1.3 ABOVE IS BASED ON NFPA 24.P:\15063_07_BC_Bozeman_Ambulatory_Dest_Center_Expansion_Site_Civil\CADD_C3D\PRODUCTION_DWG\15063_07_PnP_Water.dwg, C2.1 FIRE LINE, 8/17/2022 2:25:47 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (36.00 x 24.00 Inches), 1:108/15/22
AS-BUILTSNORTH VERTICAL SCALE: 1"=4'
20 10 0
HORIZONTAL SCALE:1" = 20'
20 40
FILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTIONFIRE LINE AND HYDRANT INFRASTRUCTURETOWNSHIP 1S., RANGE 5E., SECTION 26 P.M.M.HYDRANT MAIN PNPBILLINGS CLINIC BOZEMAN ADCLOT 2A-1, MINOR SUBDIVISIONBOZEMAN, MONTANAC2.2 -15063_07_PNP_WATER.DWGLMH08/01/22AS-BUILT RECORD DRAWINGS--------------15063.07P:\15063_07_BC_Bozeman_Ambulatory_Dest_Center_Expansion_Site_Civil\CADD_C3D\PRODUCTION_DWG\15063_07_PnP_Water.dwg, C2.2 HYDRANT MAIN, 8/17/2022 2:25:53 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (36.00 x 24.00 Inches), 1:108/15/22
AS-BUILTSFILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTIONFIRE LINE AND HYDRANT INFRASTRUCTURETOWNSHIP 1S., RANGE 5E., SECTION 26 P.M.M.FIRE LINE DETAILSBILLINGS CLINIC BOZEMAN ADCLOT 2A-1, MINOR SUBDIVISIONBOZEMAN, MONTANAC2.3 -15063_07_PNP_WATER.DWGLMH08/01/22AS-BUILT RECORD DRAWINGS--------------15063.07P:\15063_07_BC_Bozeman_Ambulatory_Dest_Center_Expansion_Site_Civil\CADD_C3D\PRODUCTION_DWG\15063_07_PnP_Water.dwg, C2.3 DETAILS, 8/17/2022 2:25:58 PM,AutoCAD PDF (General Documentation).pc3, ARCH full bleed D (36.00 x 24.00 Inches), 1:108/15/22