005 A101 Level 1 Plan
1. CONTRACTOR TO FIELD VERIFY ALL FOUNDATION AND FOOTING HEIGHTS.2. CONTRACTOR TO COORDINATE ALL SITE DRAINAGE.3. ALL STRUCTURAL ELEMENTS ARE TO BE REVIEWED BY A LICENSED STRUCTURAL ENGINEER.4. EXTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR F.O. SHEATHING/OUTSIDE FACE OF FOUNDATION.5. INTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE AND F.O. STUD FRAMING.6. ALL DOORS ARE 4 1/2" AWAY FROM STUD OR CENTERLINE OF WALL, UNLESS SPECIFICALLY DIMENSIONED.7. CONTRACTOR TO COORDINATE ALL HVAC. COORDINATE WITH ARCHITECT FOR ANY FLOOR PLAN CHANGES.8. CONTRACTOR TO COORDINATE ALL ELECTRICAL REQUIREMENTS.9. CONTRACTOR TO COORDINATE ALL STRUCTURAL SHEAR REQUIREMENTS W/ A LICENSED STRUCTURAL ENGINEER.10. UNTAGGED INTERIOR WALLS EQUALS INTERIOR PARTITION 2X4 (SSD).11. REFER TO ARCHITECTURAL SHEET SERIES 200 EXTERIOR ELEVATIONS FOR THE IDENTIFICATION OF VARIOUS EXTERIOR WALL MATERIAL TYPES, LOCATIONS, AND EXTENTS.12. COORDINATE T.O. FOUNDATION WALL AND FINISH FLOORING WITH NEW GRADE.FLOOR PLAN GENERAL NOTESWALL & CEILING NOTES:1. ALL WALL AND CEILING FINISHED SHALL HAVE A FLAME SPREAD INEDX OF NOT GREATER THAN 200, PER IRC R302.9.12. WALL AND CEILING FINISHES SHALL HAVE A SMOKE-DEVELOPED INDEX OF NOT GREATER THAN 450, PER IRC R302.9.2= FIRE WALL, SEE NOTES ON PLANS AND SECTIONSFIRE BLOCKING NOTES:1. FIREBLOCKING VERTICALLY @ FLOOR AND CEILINGS, HORIZONTALLY @ INTERVALS NO GREATER THAN 10'.2. CONCEALED SPACES (SOFFITS, DROP CEILINGS, CHASES, ETC.) PROVIDE FIREBLOCKING BETWEEN VERTICAL AND HORIZONTAL SPACES. 3A-2012A-2021A-2011A-202FRONT ENTRY101ALIVING ROOM102AKITCHEN103AKITCHEN103BLIVING ROOM102BFRONT ENTRY101BDINING ROOM104BBACK ENTRY105BPOWDER106BDINING ROOM104CLIVING ROOM102CFRONT ENTRY101CBACK ENTRY105CPOWDER106CCLOSET107CGARAGE - UNIT A108AGARAGE - UNIT B108BGARAGE - UNIT C108C1A-3021A-3012A-3012A-3022A-201101A106B104B102B101CAACCEEFFGGHH441122334' - 0"CHASECHASE104A105A106A107A103A102A103B105C107C106C104CDD102C103CPOWDER106ACLOSET107A57' - 8"23' - 3"5' - 8"30' - 1"8' - 0"45' - 8"4' - 0"8' - 1 1/4"58' - 9"19' - 5"19' - 11"19' - 5"DINING104A105B107B22' - 7"108C2108B410' - 10"5' - 9 1/2"8' - 0"6' - 0 1/2"R @7 1/2"16R @7 1/2"16R @7 1/2"16REFREFREFKNEE SPACEKNEE SPACEKNEE SPACE2' - 1"3' - 6"PANTRYB04DPANTRYB04EPANTRYB04F2' - 0"CCCFCC101BFCCCCCB01EB01FB01DCCDDFKITCHEN103CCLOSET107B2 HR FIRE WALLROOF OVERHEAD116' - 8"2' - 6"5' - 6"5' - 9 1/2"10' - 10"6' - 4"7' - 9"10' - 0"5' - 10 1/2"1' - 1"2' - 0"4' - 0"STEEL RAILINGSTEEL RAILINGBACK ENTRY105A108B1108A158' - 9"19' - 5"19' - 11"19' - 5"116' - 8"108B2108A2108B3METAL DOWNSPOUT METAL DOWNSPOUT METAL DOWNSPOUT METAL DOWNSPOUT 5' - 8"3' - 7"4' - 2"3' - 2"18' - 6 1/2"18' - 6 1/2"2' - 10"5' - 5"3' - 6"4' - 2"3' - 5"18' - 6 1/2"18' - 7 1/2"5' - 8"7' - 9"3' - 2"18' - 6 1/2"18' - 6 1/2"1' - 5"23' - 1"11' - 8"22' - 7"7' - 0"6' - 2"16' - 11"5' - 8"23' - 3"7' - 0"23' - 1"5' - 8"5' - 3 1/2"5' - 3 1/2"5' - 9 3/4"1' - 1"2' - 1"3' - 6"2' - 1"5' - 10 1/2"1' - 1"2' - 0"3' - 6"2' - 1"CC108C1BBDD2 HR FIRE WALL CONCRETE SOGSLOPE SLAB 1/8" PER 1'CONCRETE SOGSLOPE SLAB 1/8" PER 1'CONCRETE SOGSLOPE SLAB 1/8" PER 1'CONCRETE SOGSLOPE SLAB 1/8" PER 1'ROOF OVERHEADMETAL DOWNSPOUTMETAL DOWNSPOUT (TYP.)UPDNDNDNUPUPR @7 1/2"16R @7 1/2"16R @7 1/2"16PROVIDE 1 1/2" DIAMETER HANDRAIL, 36" ABOVE TREAD NOSE, RETURN ENDSCHASECHASEPROVIDE 1 1/2" DIAMETER HANDRAIL, 36" ABOVE TREAD NOSE, RETURN ENDSPROVIDE 1 1/2" DIAMETER HANDRAIL, 36" ABOVE TREAD NOSE, RETURN ENDSCHASECHASEDNDNDNDNDNDNSTEEL RAILINGSTEEL RAILINGSTEEL RAILINGSTEEL RAILING2x6 STUD2x6 STUD2x6 STUDEQEQ5' - 1"1' - 5"34' - 3"Date:45 Arch Project Number:Sheet NameALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF 45 ARCHITECTURE.ConsultantNOT FORCONSTRUCTIONREVISIONS1216 W Lincoln Street, Suite DBozeman, Montana 59715(406) 577-2345www.45arch.com5/24/2022 3:23:55 PMA-101FIRST FLOORPLAN314 W VILLARD02.25.2222007314 VILLARD ST, BOZEMAN, MT 59715MICHAEL KALICAKNORTH3/16" = 1'-0" FIRST FLOOR PLAN1NO. DESCRIPTION DATE