HomeMy WebLinkAbout019 Stormwater Maintenance Plan 2131 Graf
G:\MADISON ENGINEERING\PROJECTS\2018\18-116 Graf St Apts\Application\Subdivision\Preliminary Plat\Resubmittal\019
STORMWATER MAINTENANCE PLAN_2131 Graf_091522.doc
STORMWATER MAINTENANCE PLAN
Graf Street Apartments
Maintenance Responsibility Background
A property owners association (2131 Graf Apartments POA, Inc.), hereafter referred to as
the “POA”, has been established for the 2131 Graf Street Minor Subdivision. The
formation of the POA is for specific maintenance responsibilities of common facilities
developed for all lots within 2131 Graf Street Minor Subdivision (except Lot 1, Block 1),
including stormwater facilities. Maintenance of all stormwater facilities, including
operations, assessments, repairs, and maintenance of such facilities shall be in accordance
with the Declaration of Covenants, Conditions, and Restrictions and Easements
established for 2131 Graf Apartments POA, Inc.
Maintenance Plan
All stormwater infrastructure shall be maintained in accordance with manufacturers
recommendations for each specific infrastructure type. The POA shall maintain
operations and maintenance manuals on-site for all stormwater infrastructure. In
addition, the POA’s responsibility for routine maintenance and inspection shall be as
described below.
1. Keep the inlets of the facilities free of leaves, rocks, and other debris.
2. See that litter and other debris are removed from inlets, swales, and vegetated and
paved areas.
3. Maintenance of the underground systems are as follows:
• Minimum required maintenance includes a quarterly inspection during the
first year of operation and a yearly inspection thereafter. Utilize inspection
ports for inspections.
• The inspection ports can be used to pump water into the system and re-
suspend accumulated sediment so that is may be pumped out. Flush and
pump as inspections deem necessary.