Loading...
HomeMy WebLinkAbout70-LI201IrrigationDetailsSINGLE OUTLET EMITTER PLACEMENT SCALE: NTS DIFFUSER CAP W/ DRIP STAKE PLANT CENTER PLANT ROOTBALL SINGLE OUTLET EMITTER 3/4" POLYETHYLENE DRIP TUBING 1/4" DISTRIBUTION TUBING (LENGTH NOT TO EXCEED 8') 1 2 3 4 5 6 NOTE: 1.EMITTERS SHALL BE EQUALLY SPACED AROUND ROOTBALL. 2.FLUSH ALL LINES THOROUGHLY PRIOR TO EMITTER INSTALLATION. 2.IF PLANTING ON A 4:1 SLOPE OR STEEPER, INSTALL EMITTERS ON THE UPHILL SIDE OF PLANT. 3.EMITTERS SHALL BE SELF-FLUSHING PRESSURE COMPENSATING-TYPE UNLESS NOTED OTHERWISE. 4.DRIP VALVE ZONES (HYDROZONES) ARE DESIGNED TO ACCOUNT FOR DIFFERENCES IN PLANT REQUIREMENTS AND SUN EXPOSURE. 5.CONTRACTOR SHALL ENSURE HYDROZONES ARE VALVED SEPARATELY AS SHOWN ON PLAN. 1 2 3 4 5 6 1 3 6 56 EMISSION POINT. DIFFUSER CAP W/ DRIP STAKE (TYP.) PLANT ROOT BALL (TYP.) PLANT CENTER (TYP.) SECOND EMISSION POINTS SEE NOTE 3 BELOW TREE TRUNK MULCH LAYER 1/4" DISTRIBUTION TUBING (LENGTH NOT TO EXCEED 8') 3/4" POLYETHYLENE DRIP TUBING SINGLE OUTLET EMITTER ROOTBALL 1 2 3 4 5 6 7 8 9 10 TREE EMITTER PLACEMENT SCALE: NTS 60°60° 60° 6 0 °60°NOTE: 1.MAXIMUM LENGTH OF ONE DISTRIBUTION TUBE SHALL BE 8'. 2.ALL EMISSION POINTS SHALL BE LOCATED ON UPHILL SIDE OF PLANT MATERIAL. ONE EMISSION POINT SHALL BE DIRECTLY TO PLANT BALL AS INDICATED. ADDITIONAL EMISSION POINTS SHALL BE WITHIN PLANT PIT PERIMETER AS DIRECTED IN THE EMITTER SCHEDULE. 3.SECOND EMISSION POINTS (IF NEEDED) AS PER THE EMITTER SCHEDULE FOR TREES WITH 3" CALIPER OR GREATER OR CONIFEROUS TREES 10' OR GREATER IN HEIGHT. 4.THIS IS A WATERING GUIDE ONLY. SITE, SOIL AND PLANT CONDITIONS VARY GREATLY. CONTRACTOR MUST OBSERVE THE PLANT MATERIAL AND MAKE ADJUSTMENTS AS NECESSARY FOR PROPER PLANT WATER REQUIREMENT. 1 2 3 4 5 1 6 7 8 9 10 6" MIN. 12" MAX. 8 7 10 1/4" DISTRIBUTION TUBING. RUN TUBING UNDER WEED BARRIER FABRIC TO PLANT. LENGTH NOT TO EXCEED 8' UNIVERSAL 1/4" STAKE DIFFUSER CAP TOP OF MULCH PRESSURE COMPENSATING EMITTER PER EMITTER SCHEDULE. INSTALL EMITTER AT 45° TO 60° ANGLE 3/4" POLYETHYLENE TUBING SET WITH TOP OF TUBING FLUSH WITH FINISH GRADE OF SOIL FINISH GRADE OF SOIL WEED BARRIER FABRIC 1 2 3 4 5 6 7 8 SINGLE OUTLET EMITTER SCALE: NTS 1 2 3 4 7 5 6 8 1 2 3 4 NOTE: 1.COMPACT SOIL AROUND VALVE BOX TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUBGRADE. 2.SECURE STAKE TO FLUSH END CAP OR PVC NIPPLE WITH A MIN. OF 2 HOSE CLAMPS. 3.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 1 7 2 8 3 9 4 5 6 4" POP-UP HEAD WITH ENCLOSED NOZZLE AND SWING PIPE. (ZONE OPERATIONAL INDICATOR) LOCKING ROUND BOX & COVER PER SCHEDULE. TOP OF BOX TO BE FLUSH WITH FINISH GRADE HOSE END SELF FLUSH CAP FINISH GRADE 24" #4 REBAR TO HOLD END CAP IN PLACE W/ (2) STAINLESS STEEL HOSE CLAMPS 3/4" POLYETHYLENE DRIP TUBING ELBOW COMPRESSION FITTING 3/4" GRAVEL SUMP, 4" DEPTH BRICK (2 REQUIRED MIN.) RISER (LENGTH AS NEEDED) COMPRESSION TEE W/ POLY TO PVC ADAPTER PVC LATERAL 1 2 3 4 5 6 7 8 9 10 11 12 DRIP FLUSH END CAP WITH INDICATOR SCALE: NTS2"MIN.10 11 12 IRRIGATION DETAILS LI201 OWNER: DATE: SHEET TITLE: OWNER: DATE: SHEET TITLE:CHECKED BY:DRAWN BY:NWX APARTMENTS - AN ICON COMMUNITYSITE PLAN - PHASE 2BOZEMAN, MONTANANWX APARTMENTS LLC 1735 SOUTH 19TH AVE SUITE B BOZEMAN, MT 59718 OFFICE: 406.582.8100 FAX: 406.582.8108 GH, JSKS, RH10/29/21: SP 01 06/02/22: SP 02 244 North College Avenue #130 Fort Collins, Colorado 80524 P 970.409.3414 www.norris-design.com