Loading...
HomeMy WebLinkAbout69-LI200IrrigationDetails3 4 5 6 8 9 10 7 1 2 10 VALVE BOX WITH COVER PER LEGEND FINISH GRADE WIRE FROM LINE SURGE PROTECTOR TO GROUNDING ROD BRASS CLAMPS (1 OF 2) GROUNDING ROD: 10 OHMS OR LESS 3 INCH MINIMUM DEPTH OF 3 4 INCH WASHED GRAVEL LINE SURGE ARRESTOR: BUILT-IT ON DECODERS WATERPROOF CONNECTORS WIRE FROM DECODER TO WIRE CONNECTOR BRICK (2 MINIMUM) TWO-WIRE CABLE/COMMUNICATION WIRE TO NEXT DEVICE (FIELD DECODER, SENSOR DECODER, LINE SURGE PROTECTOR OR CONTROLLER 1 2 3 4 5 6 7 8 9 10 LINE SURGE PROTECTION SCALE: NTS NOTES: 1.INSTALL A LINE SURGE PROTECTOR EVERY 8th DECODER OR EVERY 500 FT. WHICHEVER IS SHORTER AND AT THE END OF EACH WIRE RUN. 2.INSTALL THE GROUNDING WIRE AND EACH GROUNDING HARDWARE AT RIGHT ANGLES FROM THE TWO-WIRE PATHS, WHEN POSSIBLE. 3.EACH GROUND SYSTEM SHALL MAINTAIN A MAXIMUM GROUND RESISTANCE OF 10 OHMS OR LESS. REFER TO TWO-WIRE COMPONENTS MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS FOR INSTALLATION. 4.INSTALL GROUNDING PER ASIC'S GUIDELINES. FLOW WATERPROOF CONNECTORS 30" COIL OF WIRE MINIMUM PLACED IN BOX (2) SCH. 80 PVC UNION (THREADED) PVC COUPLING (FPTxFPT) PVC LATERAL BRICK SUPPORT (4 MIN) 4" DEPTH GRAVEL SUMP VALVE BOX PER LEGEND, FLUSH TOP OF BOX W/ GRADE CONTROL VALVE PER LEGEND SCH. 80 PVC BALL VALVE CONTROL AND COMMON WIRES FROM CONTROLLER SCH. 80 TEE (SxSxT) PVC MAINLINE 1 2 3 4 5 6 7 8 9 10 11 12 13 DRIP CONTROL ZONE KIT SCALE: NTS NOTES: 1.BUNDLE & TAPE WIRE EVERY 10 FT. SEAL WIRE ENDS w/ WATERPROOF SPLICING MATERIAL. 2.30" MINIMUM LENGTH OF CONTROL WIRE COILED AND PLACED IN BOX AT WATER PROOF CONNECTION TO SOLENOID. 3.INSTALL DECODERS PER MANUFACTURER'S SPECIFICATIONS FOR WIRING AND GROUNDING. Drip valve to poly connection Refer to legend for type of connection required. POLY PVC TO POLY FITTING Drip valve to pvc connection Refer to legend for type of connection required. 3" 1 2 3 4 5 9 10 11 12 13 6 8 7 LOCKING ROUND BOX & COVER PER SCHEDULE. TOP OF BOX TO BE FLUSH WITH FINISH GRADE FINISH GRADE 8" SCH 40 PVC ACCESS SLEEVE LENGTH AS REQUIRED. GATE VALVE W/ CROSS HANDLE AND SOLID WEDGE DISC PER SCHEDULE 3/4" GRAVEL SUMP FILL IN AND AROUND BOX AS REQUIRED. 3" DEPTH 3/4: GRAVEL EXTEND 6" BEYOND EDGE OF BOX PVC MAINLINE COMPACTED SUBGRADE 1 2 3 4 5 6 7 8 NOTE: 1.COMPACT SOIL AROUND GATE VALVE ASSEMBLY TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUBGRADE. 2.DO NOT REST VALVE BOX OR ACCESS SLEEVES ON MAINLINE OR LATERAL LINE. 3.PROVIDE GATE VALVE KEY - LENGTH AS REQUIRED. CL GATE VALVE 2" AND SMALLER SCALE: NTS4" MIN.2"MIN.SEE TRENCHING DETAILFOR PIPE DEPTH4 3 2 1 6 7 5 8 SNAKE PVC OR POLYETHYLENE PIPE IN TRENCH EXCAVATED COVER MATERIAL (SEE NOTES) FINISH GRADE MAINLINE MARKING TAPE (PURPLE MARKING TAPE IF RECLAIMED) POLYETHYLENE DRIP LATERAL/ DRIP PVC LATERAL PIPE (6" MIN. COVERAGE, 18" MIN. COVERAGE BELOW PEDESTRIAN WALKS.) IRRIGATION LATERAL PIPE IRRIGATION MAINLINE PIPE VALVE WIRING BEDDING MATERIAL (SEE NOTES) 1 2 3 4 5 6 7 8 9 PLAN NOTE: 1.ALL MAINLINES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER' SPECIFICATIONS. 2.ALL PVC PIPING TO BE SNAKED IN TRENCHES AS SHOWN IN PLAN VIEW ABOVE. 3.ALL 120 VOLT WIRING IN CONDUIT TO BE INSTALLED AS PER LOCAL CODES. 4.ALL ELECTRICAL WIRE CONNECTIONS TO VALVES AND SPLICES TO BE INSTALLED WITHIN A VALVE BOX AND MADE WITH DBY WATERPROOF CONNECTORS, OR APPROVED EQUAL. 5.BUNDLE AND TAPE WIRING AT 10' INTERVALS 6.VALVE WIRES TO BE INSTALLED WITHIN MAINLINE TRENCH WHEREVER POSSIBLE. 7.BEDDING MATERIAL SHALL BE 1/4” MINUS SAND, AND SHALL BE 3” BELOW LOWEST PIPE OR WIRE AND 3” ABOVE HIGHEST PIPE OR WEIR WITHIN TRENCH. 8.BEDDING MATERIAL SHALL BE IN MAINLINE TRENCH ONLY. 9.BEDDING IS NOT REQUIRED IN POLYETHYLENE TUBING TRENCHES. 10.EXCAVATED COVER MATERIAL SHALL BE FREE FROM DEBRIS AND ROCKS 1/2” OR GREATER. 11.PIPE BEDDING MATERIAL TO BE ROCK AND DEBRIS FREE, BACKFILL IN 6” LIFTS, PUDDLE WITH WATER, BETWEEN LIFTS. SECTION PIPE TRENCH SCALE: NTS 1 9 3 8 7 6 4 2 5 24"18" 6" FINISH GRADE POP-UP SPRAY HEAD PER SCHEDULE PVC LATERAL PIPE SWING JOINT ASSEMBLY PVC SCH. 40 TEE OR ELL, (S x T) WALLS, WALKS, COURTS, CURB, ETC. 1 2 3 4 5 6 NOTE: 1.AFTER FLUSHING HEADS, REGRADE AND COMPACT AS NEEDED TO RETURN TO FINISH GRADE. 2.SPRINKLERS SHALL BE MIN. 6" FROM ANY WALLS, WALKS, COURTS, AND 12" FROM TURF EDGE. 3.ADJUST ALL SPRINKLERS HEADS SO THAT NO OVERSPRAY OCCURS ON ANY WALLS, WALKS, COURTS, ETC. 4.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 5.COMPACT SOIL AROUND HEAD TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUBGRADE. 6 SPRAY POP-UP SCALE: NTS 6" MIN. OR PER LOCAL CODE 5 1 2 3 4 FINISH GRADE 10" ROUND BOX & COVER PER SCHEDULE. TOP OF BOX TO FLUSH WITH FINISH GRADE QUICK COUPLING VALVE W/ LOCKING COVER PER SCHEDULE SCH. 80 PVC RISER (T x T) 3" DEPTH 3/4" GRAVEL BASE EXTEND 6" BEYOND EDGE OF BOX PVC SWING JOINT PVC MAINLINE 24" LONG #4 REBAR TO HOLD QUICK COUPLER IN PLACE W/ (2) STAINLESS STEEL CLAMPS 1 2 3 4 5 6 7 8 QUICK COUPLER SCALE: NTS NOTES: 1.EACH QUICK COUPLER SHALL BE IN A SEPARATE VALVE BOX. 2.PROVIDE (1) QUICK COUPLER KEY FOR EACH QUICK COUPLER VALVE. 3.QUICK COUPLER SHALL HAVE LOCKING RUBBER COVER. COLOR PER LEGEND. 4.COMPACT SOIL AROUND GATE VALVE ASSEMBLY TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUB-GRADE. 5.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 1 2 3 4 5 6 7 8 PVC MAINLINE BRICK SUPPORT (4 MIN.) CONTROL WIRE COMMON WIRE TO NEXT VALVE(S) PVC LATERAL W/ MALE ADAPTER SCH. 80 PVC UNION (THREADED) WATERPROOF CONNECTORS TWO-WIRE DECODER CONTROL VALVE (4) SCH. 80 PVC NIPPLE/ RISER (LENGTH & SIZE VARY) SCH. 80 PVC BALL VALVE LOCKING VALVE BOX FINISH GRADE PVC ELBOW (TxT) 3/4" GRAVEL SUMP - 4" DEPTH PVC TEE (SxSxT) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 3" FLOW CONTROL VALVE DECODER SCALE: NTS NOTE: 1.BUNDLE & TAPE WIRE EVERY 10 FT. SEAL WIRE ENDS WITH WATERPROOF SPLICING MATERIAL. 2.30" MINIMUM LENGTH OF CONTROL WIRE, COILED AND PLACED IN BOX AT WATERPROOF CONNECTION TO SOLENOID. 3.INSTALL DECODER PER MANUFACTURE'S SPECIFICATIONS FOR WIRING AND GROUNDING. 12 13 14 15 3 7 1 6 5 2 4 9 10 11 16 10 3 8 PAVING WRAP 12 GAUGE GALVANIZED WIRE AROUND EACH END OF SLEEVE (10 WRAPS MIN.) AND EXTEND TO SURFACE AS A LOCATING DEVICE FINISH GRADE / TOP OF DG COMPACT SOIL AROUND SLEEVE TO SAME DENSITY AS ADJACENT UNDISTURBED SOIL WASHED AND GRADED MORTAR SAND BACKFILL IN ROCKY SOIL CONDITIONS PVC SLEEVE PER SCHEDULE, TWICE DIAMETER OF THE SUM OF THE PIPES/ WIRES EXTEND SLEEVES 6" BEYOND EDGES OF PAVING 1 2 3 4 5 6 7 NOTE: 1.ALL SLEEVES SHALL BE INSPECTED PRIOR TO BACKFILLING. 2.CAP SLEEVES UNTIL USE. 3.MULTIPLE SLEEVES REQUIRE 4" HORIZONTAL SEPARATION WITHIN SAME SLEEVE TRENCH. 4.IRRIGATION PIPE AND WIRE SHALL NOT SHARE THE SAME SLEEVE. 5.MARK / STAMP - 'X' AND/OR INSTALL PLACARD AT BACK OF CURB. 6" MIN. 18" MIN. DEPTH 24" MIN. DEPTH FOR MAINLINE 1 2 3 4 5 6 7 PIPE SLEEVE SCALE: NTS 1 3 4 5 6 7 8 2 DIRECT BURY WIRE SPLICE SCALE: NTS 1. 2. 3.4. 1/2" 5. 1. STRIP ENDS OF WIRE - 1/2" 3. INSERT WIRE NUT INTO CAPSULE 4. PUSH WIRE INTO BOTTOM OF CAPSULE 2. SECURE WIRES INTO WIRE NUT 5. CLOSE COVER OF CAPSULE, SEPARATING WIRES INTO CHANNELS 6. VISUALLY CHECK THAT CONNECTOR IS BELOW LOCKING "FINGERS" NOTE: 9 IRRIGATION DETAILS LI200 OWNER: DATE: SHEET TITLE: OWNER: DATE: SHEET TITLE:CHECKED BY:DRAWN BY:NWX APARTMENTS - AN ICON COMMUNITYSITE PLAN - PHASE 2BOZEMAN, MONTANANWX APARTMENTS LLC 1735 SOUTH 19TH AVE SUITE B BOZEMAN, MT 59718 OFFICE: 406.582.8100 FAX: 406.582.8108 GH, JSKS, RH10/29/21: SP 01 06/02/22: SP 02 244 North College Avenue #130 Fort Collins, Colorado 80524 P 970.409.3414 www.norris-design.com