HomeMy WebLinkAbout112-LI501IrrigationDetailsFLOW
WATERPROOF CONNECTORS
30" COIL OF WIRE MINIMUM
PLACED IN BOX
(2) SCH. 80 PVC UNION
(THREADED)
PVC COUPLING (FPTxFPT)
PVC LATERAL
BRICK SUPPORT (4 MIN)
4" DEPTH GRAVEL SUMP
VALVE BOX PER LEGEND,
FLUSH TOP OF BOX W/ GRADE
CONTROL VALVE PER LEGEND
SCH. 80 PVC BALL VALVE
CONTROL AND COMMON
WIRES FROM CONTROLLER
SCH. 80 TEE (SxSxT)
PVC MAINLINE
1
2
3
4
5
6
7
8
9
10
11
12
13
DRIP CONTROL ZONE KIT
SCALE: NTS
NOTES:
1.BUNDLE & TAPE WIRE EVERY 10 FT. SEAL
WIRE ENDS w/ WATERPROOF SPLICING
MATERIAL.
2.30" MINIMUM LENGTH OF CONTROL WIRE
COILED AND PLACED IN BOX AT WATER
PROOF CONNECTION TO SOLENOID.
3.INSTALL DECODERS PER MANUFACTURER'S
SPECIFICATIONS FOR WIRING AND
GROUNDING.
Drip valve to poly connection
Refer to legend for type of connection required.
POLY PVC TO POLY
FITTING
Drip valve to pvc connection
Refer to legend for type of
connection required.
3"
1
2
3
4
5
9
10
11
12
13
6
8
7
SINGLE OUTLET EMITTER PLACEMENT
SCALE: NTS
DIFFUSER CAP W/ DRIP STAKE
PLANT CENTER
PLANT ROOTBALL
SINGLE OUTLET EMITTER
3/4" POLYETHYLENE DRIP TUBING
1/4" DISTRIBUTION TUBING
(LENGTH NOT TO EXCEED 8')
1
2
3
4
5
6
NOTE:
1.EMITTERS SHALL BE EQUALLY SPACED AROUND ROOTBALL.
2.FLUSH ALL LINES THOROUGHLY PRIOR TO EMITTER INSTALLATION.
2.IF PLANTING ON A 4:1 SLOPE OR STEEPER, INSTALL EMITTERS ON THE UPHILL SIDE OF PLANT.
3.EMITTERS SHALL BE SELF-FLUSHING PRESSURE COMPENSATING-TYPE UNLESS NOTED
OTHERWISE.
4.DRIP VALVE ZONES (HYDROZONES) ARE DESIGNED TO ACCOUNT FOR DIFFERENCES IN PLANT
REQUIREMENTS AND SUN EXPOSURE.
5.CONTRACTOR SHALL ENSURE HYDROZONES ARE VALVED SEPARATELY AS SHOWN ON PLAN.
1
2
3
4
5
6
1
3
6
56
EMISSION POINT. DIFFUSER CAP
W/ DRIP STAKE (TYP.)
PLANT ROOT BALL (TYP.)
PLANT CENTER (TYP.)
SECOND EMISSION POINTS SEE
NOTE 3 BELOW
TREE TRUNK
MULCH LAYER
1/4" DISTRIBUTION TUBING
(LENGTH NOT TO EXCEED 8')
3/4" POLYETHYLENE DRIP TUBING
SINGLE OUTLET EMITTER
ROOTBALL
1
2
3
4
5
6
7
8
9
10
TREE EMITTER PLACEMENT
SCALE: NTS
60°60°
60°
6
0
°60°NOTE:
1.MAXIMUM LENGTH OF ONE DISTRIBUTION TUBE SHALL BE 8'.
2.ALL EMISSION POINTS SHALL BE LOCATED ON UPHILL SIDE OF PLANT MATERIAL. ONE
EMISSION POINT SHALL BE DIRECTLY TO PLANT BALL AS INDICATED. ADDITIONAL EMISSION
POINTS SHALL BE WITHIN PLANT PIT PERIMETER AS DIRECTED IN THE EMITTER SCHEDULE.
3.SECOND EMISSION POINTS (IF NEEDED) AS PER THE EMITTER SCHEDULE FOR TREES WITH 3"
CALIPER OR GREATER OR CONIFEROUS TREES 10' OR GREATER IN HEIGHT.
4.THIS IS A WATERING GUIDE ONLY. SITE, SOIL AND PLANT CONDITIONS VARY GREATLY.
CONTRACTOR MUST OBSERVE THE PLANT MATERIAL AND MAKE ADJUSTMENTS AS
NECESSARY FOR PROPER PLANT WATER REQUIREMENT.
1
2
3
4
5
1
6
7
8
9
10
6" MIN.
12" MAX.
8
7
10
1/4" DISTRIBUTION TUBING. RUN
TUBING UNDER WEED BARRIER
FABRIC TO PLANT.
LENGTH NOT TO EXCEED 8'
UNIVERSAL 1/4" STAKE
DIFFUSER CAP
TOP OF MULCH
PRESSURE COMPENSATING
EMITTER PER EMITTER
SCHEDULE. INSTALL EMITTER AT
45° TO 60° ANGLE
3/4" POLYETHYLENE TUBING
SET WITH TOP OF TUBING FLUSH
WITH FINISH GRADE OF SOIL
FINISH GRADE OF SOIL
WEED BARRIER FABRIC
1
2
3
4
5
6
7
8
SINGLE OUTLET EMITTER
SCALE: NTS
1
2
3
4
7
5
6
8
FINISH GRADE
POP-UP SPRAY HEAD PER
SCHEDULE
PVC LATERAL PIPE
SWING JOINT ASSEMBLY
PVC SCH. 40 TEE OR ELL, (S x T)
WALLS, WALKS, COURTS, CURB,
ETC.
1
2
3
4
5
6
NOTE:
1.AFTER FLUSHING HEADS, REGRADE AND COMPACT AS NEEDED TO RETURN TO FINISH GRADE.
2.SPRINKLERS SHALL BE MIN. 6" FROM ANY WALLS, WALKS, COURTS, AND 12" FROM TURF EDGE.
3.ADJUST ALL SPRINKLERS HEADS SO THAT NO OVERSPRAY OCCURS ON ANY WALLS, WALKS,
COURTS, ETC.
4.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE.
5.COMPACT SOIL AROUND HEAD TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUBGRADE.
6
SPRAY POP-UP
SCALE: NTS
6" MIN. OR PER
LOCAL CODE
5
1
2
3
4
FINISH GRADE
(2) POP-UP SPRAY HEAD PER
SCHEDULE WITH EACH NOZZLE
0.5 GPM
PVC LATERAL PIPE
SWING JOINT ASSEMBLY
PVC SCH. 40 TEE OR ELL, (S x T)
TREE ROOT BALL
FULL CIRCLE BUBBLER
(MODEL PER LEGEND)
1
2
3
4
5
6
7
NOTE:
1.AFTER FLUSHING HEADS, REGRADE AND COMPACT AS NEEDED TO RETURN TO FINISH GRADE.
2.SPRINKLERS SHALL BE MIN. 6" FROM ANY WALLS, WALKS, COURTS, AND 24" FROM ROOT BALL.
3.ADJUST ALL SPRINKLERS BODIES SO THAT NO FLODDING OCCURS ON ANY WALLS, WALKS,
COURTS, ETC.
4.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE.
5.COMPACT SOIL AROUND HEAD TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUB-GRADE.
6
POP-UP BUBBLER
SCALE: NTS
18" MIN.
24" MAX.
5
1
2
3
4
7
PVC MAINLINE
BRICK SUPPORT (4 MIN.)
CONTROL WIRE
COMMON WIRE TO NEXT
VALVE(S)
PVC LATERAL W/ MALE ADAPTER
SCH. 80 PVC UNION (THREADED)
WATERPROOF CONNECTORS
TWO-WIRE DECODER
CONTROL VALVE
(4) SCH. 80 PVC NIPPLE/ RISER
(LENGTH & SIZE VARY)
SCH. 80 PVC BALL VALVE
LOCKING VALVE BOX
FINISH GRADE
PVC ELBOW (TxT)
3/4" GRAVEL SUMP - 4" DEPTH
PVC TEE (SxSxT)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
3"
FLOW
CONTROL VALVE DECODER
SCALE: NTS
NOTE:
1.BUNDLE & TAPE WIRE EVERY 10 FT. SEAL WIRE ENDS WITH WATERPROOF SPLICING
MATERIAL.
2.30" MINIMUM LENGTH OF CONTROL WIRE, COILED AND PLACED IN BOX AT WATERPROOF
CONNECTION TO SOLENOID.
3.INSTALL DECODER PER MANUFACTURE'S SPECIFICATIONS FOR WIRING AND GROUNDING.
12
13
14
15
3
7
1
6
5
2
4
9 10 11
16
10
3
8
NOTE:
1.COMPACT SOIL AROUND VALVE BOX TO THE SAME DENSITY AS ADJACENT UNDISTURBED
SUBGRADE.
2.SECURE STAKE TO FLUSH END CAP OR PVC NIPPLE WITH A MIN. OF 2 HOSE CLAMPS.
3.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE.
1
7
2
8
3
9
4
5
6
4" POP-UP HEAD WITH ENCLOSED
NOZZLE AND SWING PIPE. (ZONE
OPERATIONAL INDICATOR)
LOCKING ROUND BOX & COVER
PER SCHEDULE. TOP OF BOX TO
BE FLUSH WITH FINISH GRADE
HOSE END SELF FLUSH CAP
FINISH GRADE
24" #4 REBAR TO HOLD END CAP
IN PLACE W/ (2) STAINLESS STEEL
HOSE CLAMPS
3/4" POLYETHYLENE DRIP TUBING
ELBOW COMPRESSION FITTING
3/4" GRAVEL SUMP, 4" DEPTH
BRICK (2 REQUIRED MIN.)
RISER (LENGTH AS NEEDED)
COMPRESSION TEE W/ POLY TO
PVC ADAPTER
PVC LATERAL
1
2
3
4
5
6
7
8
9
10
11
12
DRIP FLUSH END CAP WITH INDICATOR
SCALE: NTS2"MIN.10
11
12
1 3
4 5 6
7 8
2
9
FINISH GRADE
12" POP-UP SPRAY HEAD PER
SCHEDULE
PVC LATERAL PIPE PER
SCHEDULE
SWING JOINT ASSEMBLY
PVC SCH. 40 TEE OR ELL, (S x T)
WALLS, WALKS, COURTS, CURB,
ETC.
1
2
3
4
5
6
NOTE:
1.AFTER FLUSHING HEADS, REGRADE AND COMPACT AS NEEDED TO RETURN TO FINISH GRADE.
2.SPRINKLERS HEAD SHALL BE LEVEL WITH SURROUNDING FINISHED GRADE.
3.ADJUST ALL SPRINKLERS HEADS SO THAT NO OVERSPRAY OCCURS ON ANY WALLS, WALKS, COURTS, ETC.
4.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE.
5.COMPACT SOIL AROUND HEAD TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUBGRADE.
6
12 INCH POP-UP SPRAY
SCALE: NTS
6" MIN. OR PER
LOCAL CODE
5
1
2
3
4
IRRIGATION
DETAILS
LI501
OWNER:
DATE:
SHEET TITLE:
OWNER:
DATE:
SHEET TITLE:CHECKED BY:DRAWN BY:NWX APARTMENTS - AN ICON COMMUNITYSITE PLAN - PHASE 1BOZEMAN, MONTANANWX APARTMENTS LLC
1735 SOUTH 19TH AVE
SUITE B
BOZEMAN, MT 59718
OFFICE: 406.582.8100
FAX: 406.582.8108
GH, JSKS, RH10/29/21: SP 01
06/02/22: SP 02
244 North College Avenue #130
Fort Collins, Colorado 80524
P 970.409.3414
www.norris-design.com