HomeMy WebLinkAbout40-C5.6DetailsStormAS REQUIRED USING VARIABLE LENGTH SECTIONS AS REQUIRED MANHOLE STEPS AT 16" ON CENTER 24" OPENING FLAT SLAB COVER CUTOUTS AS REQUIRED PRECAST OR POURED-IN-PLACE BASE. POURED-IN-PLACE BASE, MINIMUM CONCRETE THICKNESS BELOW PIPE IS EIGHT INCHES (8"). PRECAST BASE, MINIMUM THICKNESS TO BE SIX INCHES (6"). POURED-IN-PLACE BASE TO EXTEND BEYOND OUTER EDGE OF MANHOLE WALL. NOTES: 1.ALL JOINTS BETWEEN MANHOLE SECTIONS, ADJUSTING RINGS, MANHOLE RING & TOP SECTION, AND AROUND PIPE INTO MANHOLE SHALL BE WATERTIGHT. JOINTING MATERIAL SHALL BE "RAM-NEK" OR APPROVED EQUAL FOR ALL JOINTS EXCEPT BETWEEN PIPE AND MANHOLE WALL. 2.ADJUSTING RINGS AND CASTING SHALL BE CENTERED ON MANHOLE. 3.REMOVE SHIMS AND GROUT ANY GAPS BETWEEN THE CASTING, ADJUSTING RINGS, AND BARREL. REMOVE EXCESS GROUT. 4.GROUT ALL LIFTING HOLES IN BARREL. 5.ALL LATERAL PIPES SHALL BE FINISHED FLUSH WITH INNER BARREL WALL. MATCH TOP OF CURB ELEVATION EJIW 7030 SERIES CURB INLET FRAME, GRATE, & CURB HOOD VARIES - REFER TO PLAN SLOPE SHELF AT 1" PER FOOT RADIUS OF MANHOLE SECTION A-A FRAME AND COVER TO BE EITHER D&L A-1172 RING & A-1178 COVER, EJIW 3771 / 3772 SERIES, OR APPROVED EQUAL. (COVERS SHALL BE STAMPED WITH THE WORDS "SANITARY SEWER" OR "STORM SEWER" AS APPROPRIATE AND HAVE TWO 1" PICK HOLES) MANHOLE RING AND COVER SHALL BE ADJUSTED TO GRADE OF PAVEMENT SURFACE AS REQUIRED USING VARIABLE LENGTH SECTIONS AS REQUIRED MANHOLE STEPS AT 16" ON CENTER 24" OR 27" OPENING ADJUSTABLE RINGS 4" MIN TO 12" MAX FLAT SLAB COVER CUTOUTS AS REQUIRED A A CHANNEL = 1/2 DIAMETER OF PIPE SHELF: SLOPE AT 1" PER FOOT TOWARDS CHANNEL SEE CHANNEL DETAIL PRECAST OR POURED-IN-PLACE BASE. POURED-IN-PLACE BASE, MINIMUM CONCRETE THICKNESS BELOW PIPE IS EIGHT INCHES (8"). PRECAST BASE, MINIMUM THICKNESS TO BE SIX INCHES (6"). POURED-IN-PLACE BASE TO EXTEND BEYOND OUTER EDGE OF MANHOLE WALL. NOTES: 1.ALL JOINTS BETWEEN MANHOLE SECTIONS, ADJUSTING RINGS, MANHOLE RING & TOP SECTION, AND AROUND PIPE INTO MANHOLE SHALL BE WATERTIGHT. JOINTING MATERIAL SHALL BE "RAM-NEK" OR APPROVED EQUAL FOR ALL JOINTS EXCEPT BETWEEN PIPE AND MANHOLE WALL. 2.ADJUSTING RINGS AND CASTING SHALL BE CENTERED ON MANHOLE. 3.REMOVE SHIMS AND GROUT ANY GAPS BETWEEN THE CASTING, ADJUSTING RINGS, AND BARREL. REMOVE EXCESS GROUT. 4.GROUT ALL LIFTING HOLES IN BARREL. 5.ALL LATERAL PIPES SHALL BE FINISHED FLUSH WITH INNER BARREL WALL. NOTE: STORM DRAIN MANHOLES SHALL NOT HAVE FORMED CHANNELS AND THE LOWEST PIPE INVERT SHALL BE NINE INCHES (9") HIGHER THAN THE BOTTOM OF THE MANHOLE. (5) ADAPTER ANGLES VARIABLE 0° - 360° ACCORDING TO PLANS 9" SUMP 4" MIN BEDDING MIN PIPE COVER = 12" (DEPTH PER PLAN) A-2000 DRAIN PIPE WATERTIGHT JOINT, FITTINGS AS NECESSARY INTEGRATED FRAME/GRATE PER PLAN, REDUCERS/FITTINGS AS NECESSARY NYLOPLAST 24" DRAIN BASIN FINISHED SURFACE PER PLAN 24" DIA NOTE: 1.FOR ALL INLETS 5FT DEEP OR LESS, UNLESS OTHERWISE NOTED IN PLANS. 2.INCLUDES ALL FITTINGS AND NECESSARY APPURTENANCES. NOT TO SCALE COMBINATION MANHOLE & INLET DETAIL NOT TO SCALE STANDARD STRAIGHT MANHOLE DETAIL NOT TO SCALE ADS NYLOPLAST DRAIN BASIN --------DETAILS- STORM C5.6.MEE OWNER: DATE: SHEET TITLE: OWNER: DATE: SHEET TITLE:CHECKED BY:DRAWN BY:NWX APARTMENTS- AN ICON COMMUNITYBOZEMAN, MONTANABLACKRIDGE COMPANIES 1735 SOUTH 19TH AVE SUITE B BOZEMAN, MT 59718 OFFICE: 406.582.8100 FAX: 406.582.8108 244 North College Avenue #130 Fort Collins, Colorado 80524 P 970.409.3414 www.norris-design.com 10/29/2021 NOT TO SCALE CONCRETE STORM DRAINAGE OUTLET AND INLET CHASES MASTER SITE PLAN10/29/21: MSP 01 06/02/22: MSP 01