HomeMy WebLinkAbout135-LI501IrrigationDetailsFLOW WATERPROOF CONNECTORS 30" COIL OF WIRE MINIMUM PLACED IN BOX (2) SCH. 80 PVC UNION (THREADED) PVC COUPLING (FPTxFPT) PVC LATERAL BRICK SUPPORT (4 MIN) 4" DEPTH GRAVEL SUMP VALVE BOX PER LEGEND, FLUSH TOP OF BOX W/ GRADE CONTROL VALVE PER LEGEND SCH. 80 PVC BALL VALVE CONTROL AND COMMON WIRES FROM CONTROLLER SCH. 80 TEE (SxSxT) PVC MAINLINE 1 2 3 4 5 6 7 8 9 10 11 12 13 DRIP CONTROL ZONE KIT SCALE: NTS NOTES: 1.BUNDLE & TAPE WIRE EVERY 10 FT. SEAL WIRE ENDS w/ WATERPROOF SPLICING MATERIAL. 2.30" MINIMUM LENGTH OF CONTROL WIRE COILED AND PLACED IN BOX AT WATER PROOF CONNECTION TO SOLENOID. 3.INSTALL DECODERS PER MANUFACTURER'S SPECIFICATIONS FOR WIRING AND GROUNDING. Drip valve to poly connection Refer to legend for type of connection required. POLY PVC TO POLY FITTING Drip valve to pvc connection Refer to legend for type of connection required. 3" 1 2 3 4 5 9 10 11 12 13 6 8 7 SINGLE OUTLET EMITTER PLACEMENT SCALE: NTS DIFFUSER CAP W/ DRIP STAKE PLANT CENTER PLANT ROOTBALL SINGLE OUTLET EMITTER 3/4" POLYETHYLENE DRIP TUBING 1/4" DISTRIBUTION TUBING (LENGTH NOT TO EXCEED 8') 1 2 3 4 5 6 NOTE: 1.EMITTERS SHALL BE EQUALLY SPACED AROUND ROOTBALL. 2.FLUSH ALL LINES THOROUGHLY PRIOR TO EMITTER INSTALLATION. 2.IF PLANTING ON A 4:1 SLOPE OR STEEPER, INSTALL EMITTERS ON THE UPHILL SIDE OF PLANT. 3.EMITTERS SHALL BE SELF-FLUSHING PRESSURE COMPENSATING-TYPE UNLESS NOTED OTHERWISE. 4.DRIP VALVE ZONES (HYDROZONES) ARE DESIGNED TO ACCOUNT FOR DIFFERENCES IN PLANT REQUIREMENTS AND SUN EXPOSURE. 5.CONTRACTOR SHALL ENSURE HYDROZONES ARE VALVED SEPARATELY AS SHOWN ON PLAN. 1 2 3 4 5 6 1 3 6 56 EMISSION POINT. DIFFUSER CAP W/ DRIP STAKE (TYP.) PLANT ROOT BALL (TYP.) PLANT CENTER (TYP.) SECOND EMISSION POINTS SEE NOTE 3 BELOW TREE TRUNK MULCH LAYER 1/4" DISTRIBUTION TUBING (LENGTH NOT TO EXCEED 8') 3/4" POLYETHYLENE DRIP TUBING SINGLE OUTLET EMITTER ROOTBALL 1 2 3 4 5 6 7 8 9 10 TREE EMITTER PLACEMENT SCALE: NTS 60°60° 60° 6 0 °60°NOTE: 1.MAXIMUM LENGTH OF ONE DISTRIBUTION TUBE SHALL BE 8'. 2.ALL EMISSION POINTS SHALL BE LOCATED ON UPHILL SIDE OF PLANT MATERIAL. ONE EMISSION POINT SHALL BE DIRECTLY TO PLANT BALL AS INDICATED. ADDITIONAL EMISSION POINTS SHALL BE WITHIN PLANT PIT PERIMETER AS DIRECTED IN THE EMITTER SCHEDULE. 3.SECOND EMISSION POINTS (IF NEEDED) AS PER THE EMITTER SCHEDULE FOR TREES WITH 3" CALIPER OR GREATER OR CONIFEROUS TREES 10' OR GREATER IN HEIGHT. 4.THIS IS A WATERING GUIDE ONLY. SITE, SOIL AND PLANT CONDITIONS VARY GREATLY. CONTRACTOR MUST OBSERVE THE PLANT MATERIAL AND MAKE ADJUSTMENTS AS NECESSARY FOR PROPER PLANT WATER REQUIREMENT. 1 2 3 4 5 1 6 7 8 9 10 6" MIN. 12" MAX. 8 7 10 1/4" DISTRIBUTION TUBING. RUN TUBING UNDER WEED BARRIER FABRIC TO PLANT. LENGTH NOT TO EXCEED 8' UNIVERSAL 1/4" STAKE DIFFUSER CAP TOP OF MULCH PRESSURE COMPENSATING EMITTER PER EMITTER SCHEDULE. INSTALL EMITTER AT 45° TO 60° ANGLE 3/4" POLYETHYLENE TUBING SET WITH TOP OF TUBING FLUSH WITH FINISH GRADE OF SOIL FINISH GRADE OF SOIL WEED BARRIER FABRIC 1 2 3 4 5 6 7 8 SINGLE OUTLET EMITTER SCALE: NTS 1 2 3 4 7 5 6 8 FINISH GRADE POP-UP SPRAY HEAD PER SCHEDULE PVC LATERAL PIPE SWING JOINT ASSEMBLY PVC SCH. 40 TEE OR ELL, (S x T) WALLS, WALKS, COURTS, CURB, ETC. 1 2 3 4 5 6 NOTE: 1.AFTER FLUSHING HEADS, REGRADE AND COMPACT AS NEEDED TO RETURN TO FINISH GRADE. 2.SPRINKLERS SHALL BE MIN. 6" FROM ANY WALLS, WALKS, COURTS, AND 12" FROM TURF EDGE. 3.ADJUST ALL SPRINKLERS HEADS SO THAT NO OVERSPRAY OCCURS ON ANY WALLS, WALKS, COURTS, ETC. 4.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 5.COMPACT SOIL AROUND HEAD TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUBGRADE. 6 SPRAY POP-UP SCALE: NTS 6" MIN. OR PER LOCAL CODE 5 1 2 3 4 FINISH GRADE (2) POP-UP SPRAY HEAD PER SCHEDULE WITH EACH NOZZLE 0.5 GPM PVC LATERAL PIPE SWING JOINT ASSEMBLY PVC SCH. 40 TEE OR ELL, (S x T) TREE ROOT BALL FULL CIRCLE BUBBLER (MODEL PER LEGEND) 1 2 3 4 5 6 7 NOTE: 1.AFTER FLUSHING HEADS, REGRADE AND COMPACT AS NEEDED TO RETURN TO FINISH GRADE. 2.SPRINKLERS SHALL BE MIN. 6" FROM ANY WALLS, WALKS, COURTS, AND 24" FROM ROOT BALL. 3.ADJUST ALL SPRINKLERS BODIES SO THAT NO FLODDING OCCURS ON ANY WALLS, WALKS, COURTS, ETC. 4.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 5.COMPACT SOIL AROUND HEAD TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUB-GRADE. 6 POP-UP BUBBLER SCALE: NTS 18" MIN. 24" MAX. 5 1 2 3 4 7 PVC MAINLINE BRICK SUPPORT (4 MIN.) CONTROL WIRE COMMON WIRE TO NEXT VALVE(S) PVC LATERAL W/ MALE ADAPTER SCH. 80 PVC UNION (THREADED) WATERPROOF CONNECTORS TWO-WIRE DECODER CONTROL VALVE (4) SCH. 80 PVC NIPPLE/ RISER (LENGTH & SIZE VARY) SCH. 80 PVC BALL VALVE LOCKING VALVE BOX FINISH GRADE PVC ELBOW (TxT) 3/4" GRAVEL SUMP - 4" DEPTH PVC TEE (SxSxT) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 3" FLOW CONTROL VALVE DECODER SCALE: NTS NOTE: 1.BUNDLE & TAPE WIRE EVERY 10 FT. SEAL WIRE ENDS WITH WATERPROOF SPLICING MATERIAL. 2.30" MINIMUM LENGTH OF CONTROL WIRE, COILED AND PLACED IN BOX AT WATERPROOF CONNECTION TO SOLENOID. 3.INSTALL DECODER PER MANUFACTURE'S SPECIFICATIONS FOR WIRING AND GROUNDING. 12 13 14 15 3 7 1 6 5 2 4 9 10 11 16 10 3 8 NOTE: 1.COMPACT SOIL AROUND VALVE BOX TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUBGRADE. 2.SECURE STAKE TO FLUSH END CAP OR PVC NIPPLE WITH A MIN. OF 2 HOSE CLAMPS. 3.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 1 7 2 8 3 9 4 5 6 4" POP-UP HEAD WITH ENCLOSED NOZZLE AND SWING PIPE. (ZONE OPERATIONAL INDICATOR) LOCKING ROUND BOX & COVER PER SCHEDULE. TOP OF BOX TO BE FLUSH WITH FINISH GRADE HOSE END SELF FLUSH CAP FINISH GRADE 24" #4 REBAR TO HOLD END CAP IN PLACE W/ (2) STAINLESS STEEL HOSE CLAMPS 3/4" POLYETHYLENE DRIP TUBING ELBOW COMPRESSION FITTING 3/4" GRAVEL SUMP, 4" DEPTH BRICK (2 REQUIRED MIN.) RISER (LENGTH AS NEEDED) COMPRESSION TEE W/ POLY TO PVC ADAPTER PVC LATERAL 1 2 3 4 5 6 7 8 9 10 11 12 DRIP FLUSH END CAP WITH INDICATOR SCALE: NTS2"MIN.10 11 12 1 3 4 5 6 7 8 2 9 FINISH GRADE 12" POP-UP SPRAY HEAD PER SCHEDULE PVC LATERAL PIPE PER SCHEDULE SWING JOINT ASSEMBLY PVC SCH. 40 TEE OR ELL, (S x T) WALLS, WALKS, COURTS, CURB, ETC. 1 2 3 4 5 6 NOTE: 1.AFTER FLUSHING HEADS, REGRADE AND COMPACT AS NEEDED TO RETURN TO FINISH GRADE. 2.SPRINKLERS HEAD SHALL BE LEVEL WITH SURROUNDING FINISHED GRADE. 3.ADJUST ALL SPRINKLERS HEADS SO THAT NO OVERSPRAY OCCURS ON ANY WALLS, WALKS, COURTS, ETC. 4.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 5.COMPACT SOIL AROUND HEAD TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUBGRADE. 6 12 INCH POP-UP SPRAY SCALE: NTS 6" MIN. OR PER LOCAL CODE 5 1 2 3 4 LI501 IRRIGATION DETAILS OWNER: DATE: SHEET TITLE: OWNER: DATE: SHEET TITLE:CHECKED BY:DRAWN BY:NWX APARTMENTS - AN ICON COMMUNITYMASTER SITE PLANBOZEMAN, MONTANANWX APARTMENTS LLC 1735 SOUTH 19TH AVE SUITE B BOZEMAN, MT 59718 OFFICE: 406.582.8100 FAX: 406.582.8108 GH, JSKS, RH10/29/21: MSP 01 06/02/22: MSP 02 244 North College Avenue #130 Fort Collins, Colorado 80524 P 970.409.3414 www.norris-design.com