HomeMy WebLinkAbout134-LI500IrrigationDetailsNOTE: 1.ALL ELECTRICAL AND CONTROLLER WIRE TO BE INSTALLED PER LOCAL CODE AND MANUFACTURER'S SPECIFICATIONS. 2.PROVIDE LOCK AND KEY FOR ENCLOSURE. 3.GROUND CONTROLLER PER LOCAL CODE, MANUFACTURER AND ASIC SPECIFICATIONS. 4.PROVIDE WATERPROOF SEALANT FOR ALL CONDUIT AND WIRE ACCESS POINTS. 1 2 3 4 5 6 7 METAL ENCLOSURE CONTROLLER PER SCHEDULE METAL PEDESTAL MOUNT ENCLOSURE PER SCHEDULE 1" ELECTRICAL SUPPLY CONDUIT: SIZE, TYPE, DEPTH PER LOCAL CODE GROUND WIRE CONDUIT MIN. 1-1/2". GROUND PER ASIC GUIDELINES. 6" THICK CONCRETE BASE WITH SLEEVES FOR CONDUIT FINISH GRADE CONDUIT FOR DIRECT BURY CONTROL WIRES. EXTEND CONDUIT 5' FROM CONTROLLER 1 2 3 4 5 6 7 CONTROLLER PEDESTAL SCALE: NTS 3 4 5 6 8 9 10 7 1 2 10 VALVE BOX WITH COVER PER LEGEND FINISH GRADE WIRE FROM LINE SURGE PROTECTOR TO GROUNDING ROD BRASS CLAMPS (1 OF 2) GROUNDING ROD: 10 OHMS OR LESS 3 INCH MINIMUM DEPTH OF 3 4 INCH WASHED GRAVEL LINE SURGE ARRESTOR: BUILT-IT ON DECODERS WATERPROOF CONNECTORS WIRE FROM DECODER TO WIRE CONNECTOR BRICK (2 MINIMUM) TWO-WIRE CABLE/COMMUNICATION WIRE TO NEXT DEVICE (FIELD DECODER, SENSOR DECODER, LINE SURGE PROTECTOR OR CONTROLLER 1 2 3 4 5 6 7 8 9 10 LINE SURGE PROTECTION SCALE: NTS NOTES: 1.INSTALL A LINE SURGE PROTECTOR EVERY 8th DECODER OR EVERY 500 FT. WHICHEVER IS SHORTER AND AT THE END OF EACH WIRE RUN. 2.INSTALL THE GROUNDING WIRE AND EACH GROUNDING HARDWARE AT RIGHT ANGLES FROM THE TWO-WIRE PATHS, WHEN POSSIBLE. 3.EACH GROUND SYSTEM SHALL MAINTAIN A MAXIMUM GROUND RESISTANCE OF 10 OHMS OR LESS. REFER TO TWO-WIRE COMPONENTS MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS FOR INSTALLATION. 4.INSTALL GROUNDING PER ASIC'S GUIDELINES. LOCKING ROUND BOX & COVER PER SCHEDULE. TOP OF BOX TO BE FLUSH WITH FINISH GRADE FINISH GRADE 8" SCH 40 PVC ACCESS SLEEVE LENGTH AS REQUIRED. GATE VALVE W/ CROSS HANDLE AND SOLID WEDGE DISC PER SCHEDULE 3/4" GRAVEL SUMP FILL IN AND AROUND BOX AS REQUIRED. 3" DEPTH 3/4: GRAVEL EXTEND 6" BEYOND EDGE OF BOX PVC MAINLINE COMPACTED SUBGRADE 1 2 3 4 5 6 7 8 NOTE: 1.COMPACT SOIL AROUND GATE VALVE ASSEMBLY TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUBGRADE. 2.DO NOT REST VALVE BOX OR ACCESS SLEEVES ON MAINLINE OR LATERAL LINE. 3.PROVIDE GATE VALVE KEY - LENGTH AS REQUIRED. CL GATE VALVE 2" AND SMALLER SCALE: NTS4" MIN.2"MIN.SEE TRENCHING DETAILFOR PIPE DEPTH4 3 2 1 6 7 5 8 FINISH GRADE 10" ROUND BOX & COVER PER SCHEDULE. TOP OF BOX TO FLUSH WITH FINISH GRADE QUICK COUPLING VALVE W/ LOCKING COVER PER SCHEDULE SCH. 80 PVC RISER (T x T) 3" DEPTH 3/4" GRAVEL BASE EXTEND 6" BEYOND EDGE OF BOX PVC SWING JOINT PVC MAINLINE 24" LONG #4 REBAR TO HOLD QUICK COUPLER IN PLACE W/ (2) STAINLESS STEEL CLAMPS 1 2 3 4 5 6 7 8 QUICK COUPLER SCALE: NTS NOTES: 1.EACH QUICK COUPLER SHALL BE IN A SEPARATE VALVE BOX. 2.PROVIDE (1) QUICK COUPLER KEY FOR EACH QUICK COUPLER VALVE. 3.QUICK COUPLER SHALL HAVE LOCKING RUBBER COVER. COLOR PER LEGEND. 4.COMPACT SOIL AROUND GATE VALVE ASSEMBLY TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUB-GRADE. 5.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 1 2 3 4 5 6 7 8 4 3 2 1 NOTE: 1.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 2.LOCATE DRAIN VALVE AT POINT OF CONNECTION AND AT ALL LOW POINT(S) ALONG THE IRRIGATION MAINLINE AS NEEDED. 5 6 7 8 9 10 11 12 13 MANUAL DRAIN VALVE SCALE: NTS 10" LOCKING ROUND BOX & COVER PER SCHEDULE. TOP OF BOX TO BE FLUSH WITH FINISH GRADE. 2" VALVE MARKER 2" CL160 PVC ACCESS SLEEVE LENGTH AS REQUIRED. 3" DEPTH 3/4" CRUSHED GRAVEL 6" BEYOND EDGE OF BOX PVC PRESSURE MAIN LINE SCH. 80 TEE PER MAINLINE SIZE. ALIGN IN A DOWNWARD POSITION SCH. 80 PVC NIPPLE FINISH GRADE 1" BRONZE STOP VALVE WITH SLOTTED KEY OPERATOR SCH. 80 PVC ELL SCH. 80 PVC NIPPLE 3/4" GRAVEL SUMP - 1 CU. FT. MIN SOIL BLANKET ENCLOSING SUMP AMOCO ENG. FABRIC 4545 - 4.5 OZ. OR EQUAL 1 2 3 4 5 6 7 8 9 10 11 12 13 1 3 4 5 6 7 8 NOTE: 1.INSTALL PER MANUFACTURER'S SPECIFICATIONS. 2.SLOPE TOP OF FOOTER AWAY FROM POLE. 3.FINAL LOCATION AND MOUNTING SYSTEM TO BE APPROVED BY OWNER. 4.SENSOR SHOULD NOT BE MOUNTED UNDER TREES, IN AREAS AFFECTED BY SPRINKLER SYSTEM OR UNDER EAVE OF HOUSE.36" MIN.12" MIN.12" DIA. 1 2 3 4 10' MIN.RAIN SENSOR POLE MOUNT NTS WIRELESS RAIN SENSOR, LOCATE WITHIN 500' OF THE CONTROLLER. 2" SQ., 12 GUAGE GALVANIZED STEEL POST. COLOR TO BE POWDERCOAT BLACK CONCRETE BASE-FORM WITH SONOTUBE OR EQ. POST SHALL BE CENTERED WITHIN BASE. ALL CONCERET SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4,000 PSI AT 28 DAYS OR PER SOILS REPORT. COMPACTED SUBGRADE 1 2 3 4 2 DIRECT BURY WIRE SPLICE SCALE: NTS 1. 2. 3.4. 1/2" 5. 1. STRIP ENDS OF WIRE - 1/2" 3. INSERT WIRE NUT INTO CAPSULE 4. PUSH WIRE INTO BOTTOM OF CAPSULE 2. SECURE WIRES INTO WIRE NUT 5. CLOSE COVER OF CAPSULE, SEPARATING WIRES INTO CHANNELS 6. VISUALLY CHECK THAT CONNECTOR IS BELOW LOCKING "FINGERS" NOTE: 9 10" DIA. ROUND PLASTIC VALVE BOX SOLVENT WELD CAP FINISH GRADE 24" #4 REBAR TO HOLD CAP IN PLACE W/ (2) STAINLESS STEEL CLAMPS PVC RISER PEA GRAVEL SUMP PVC MAINLINE SCH 80 PVC 90° ELL 2-WIRE BUNDLE FOR FUTURE CONNECTION. MIN 30" 1 2 3 4 5 6 7 8 9 MAINLINE END CAP SCALE: NTS 3" 1 7 2 8 3 4 5 6 6" 9 CARSON 1730 VALVE BOX STACKED AS NEEDED TO BE FLUSH WITH FINISH GRADE WATERPROOF ELECTRICAL CONNECTORS (DO NOT USE PRE-FILLED TYPE CONNECTORS) HYDROMETER PER SCHEDULE FLOW SENSOR WIRE TO CONTROLLER PVC FLANGED UNION (2) PVC MAINLINE CONCRETE PAVER 3/4" GRAVEL SUMP - 8" DEPTH BRICK SUPPORTS 2 MIN. 1 2 3 4 5 6 7 8 9 3" MIN. NOTES : 1.NO STRAIGHT PIPE UPSTREAM AND DOWNSTREAM OF HYDROMETER IS REQUIRED. 2.THE INSTALLATION OF AN ISOLATION VALVE UPSTREAM OF THE HYDROMETER IS RECOMMENDED. HYDROMETER SCALE: NTS 2 3 4 5 6 7 1 8 9 LI500 IRRIGATION DETAILS OWNER: DATE: SHEET TITLE: OWNER: DATE: SHEET TITLE:CHECKED BY:DRAWN BY:NWX APARTMENTS - AN ICON COMMUNITYMASTER SITE PLANBOZEMAN, MONTANANWX APARTMENTS LLC 1735 SOUTH 19TH AVE SUITE B BOZEMAN, MT 59718 OFFICE: 406.582.8100 FAX: 406.582.8108 GH, JSKS, RH10/29/21: MSP 01 06/02/22: MSP 02 244 North College Avenue #130 Fort Collins, Colorado 80524 P 970.409.3414 www.norris-design.com