HomeMy WebLinkAbout120-LS505SiteDetailsOWNER:
DATE:
SHEET TITLE:
OWNER:
DATE:
SHEET TITLE:CHECKED BY:DRAWN BY:NWX APARTMENTS - AN ICON COMMUNITYSITE PLAN - PHASE 1BOZEMAN, MONTANANWX APARTMENTS LLC
1735 SOUTH 19TH AVE
SUITE B
BOZEMAN, MT 59718
OFFICE: 406.582.8100
FAX: 406.582.8108
GH, JSKS, RH10/29/21: SP 01
06/02/22: SP 02
244 North College Avenue #130
Fort Collins, Colorado 80524
P 970.409.3414
www.norris-design.com
SITE DETAILS
LS505
1
7'-6"
CLEAR
9'-0"
REF.9'-0"
FRAME, COLOR: SLATE
PANEL, COLOR: SLATE
POST LOCATIONS RE:
LANDSCAPE PLAN FOR EXACT
LOCATIONS
POOL DECK/FINISHED GRADE
CONCRETE FOOTING, RE:
STRUCTURAL FOR REBAR
PLACEMENT AND FOOTING
DESIGN. STRUCTURAL FOOTING
SHALL MEET ALL APPLICABLE
CODES.
CABANA LIGHTING, RE:
ELECTRICAL
ELECTRICAL/CONDUIT HAND
HOLE ACCESS (ON BOTH
COLUMNS)
PVC CONDUIT TO BE RECESSED
WITHIN COLUMN
2
3
4
5
6
7
8
9
POOL CABANA SECTION/ELEVATION A
SCALE: 1/2" = 1'-0"
NOTES:
1.TO BE INSTALLED PER MANUFACTURERS SPECIFICATIONS.
2.REFERENCE THE LANDSCAPE PLAN FOR POST LOCATIONS.
6"
ELEVATION A ELEVATION B
3
5
1
5
PANEL PATTERN
6
6 6
10'-0"
10'-0"
PLAN VIEW
3
10'-0"
EQ.
DISTANCE
EQ.
DISTANCE
8 8
9
1'-2"
5'-11"
5'X10'
(PANEL A)
5'X10'
(PANEL B)
10x10 CABANA FRAME AND
SHADE STRUCTURE PROVIDED
BY POLIGON SHADE
STRUCTURES, MODEL: FRAME:
CUSTOM DESIGN
ROOF PANEL: LEMON DROP
CONTACT: 800.354.7721
1
2
7
CABANA SECTION/ELEVATION B
SCALE: 1/2" = 1'-0"
2'-9"
9'-10"
9'-10"
10x10 CABANA FRAME AND
SHADE STRUCTURE PROVIDED
BY POLIGON SHADE
STRUCTURES, MODEL: FRAME:
CUSTOM DESIGN
COLOR: SLATE
PANEL: LEMON DROP
COLOR: SLATE
CONTACT: 800.354.7721
FRAME
TRUSS TO SUPPORT PANELS
POST LOCATIONS RE:
LANDSCAPE PLAN FOR EXACT
LOCATIONS
FOOTING, RE: STRUCTURAL,
FOOTING DESIGN TO MEET ALL
APPLICABLE CODES. RE:
MANUFACTURE DETAIL
HAND HOLE LOCATION,
PROVIDE (1) HAND HOLE
LOCATION ON EACH POST AND
RECESS CONDUIT WITHIN
POST.
1
2
3
4
5
6
NOTES:
1.TO BE INSTALLED PER
MANUFACTURER'S SPECIFICATIONS
2.REFERENCE THE LANDSCAPE PLAN
FOR POST LOCATIONS.
6
5
4
2
1
3
6
4
3
5
CABANA SECTION/ELEVATION B
SCALE: 1/2" = 1'-0"
2'-9"
9'-10"
9'-10"
10x10 CABANA FRAME AND
SHADE STRUCTURE PROVIDED
BY POLIGON SHADE
STRUCTURES, MODEL: FRAME:
CUSTOM DESIGN
COLOR: SLATE
PANEL: LEMON DROP
COLOR: SLATE
CONTACT: 800.354.7721
FRAME
TRUSS TO SUPPORT PANELS
POST LOCATIONS RE:
LANDSCAPE PLAN FOR EXACT
LOCATIONS
FOOTING, RE: STRUCTURAL,
FOOTING DESIGN TO MEET ALL
APPLICABLE CODES. RE:
MANUFACTURE DETAIL
HAND HOLE LOCATION,
PROVIDE (1) HAND HOLE
LOCATION ON EACH POST AND
RECESS CONDUIT WITHIN
POST.
1
2
3
4
5
6
NOTES:
1.TO BE INSTALLED PER
MANUFACTURER'S SPECIFICATIONS
2.REFERENCE THE LANDSCAPE PLAN
FOR POST LOCATIONS.
6
5
4
2
1
3
6
4
3
5
NOTES:
1.REFER TO THE GEOTECHNICAL REPORT FOR SPECIFIC CONDITIONS RELATED TO THIS DETAIL.
2.NORRIS DESIGN HAS PROVIDED THIS DETAIL FOR REFERENCE AND PRICING PURPOSES AT THE DIRECTION OF THE OWNER. THIS
STRUCTURAL FOOTING AND REINFORCEMENT HAS NOT BEEN ENGINEERED AND WILL REQUIRE STAMPED PLANS PREPARED BY A LOCALLY
LICENSED MONTANA ENGINEER. NORRIS DESIGN IS NOT RESPONSIBLE FOR THE PERFORMANCE OR INTEGRITY OF THIS STRUCTURAL
FOOTING DETAIL. VERIFY STRUCTURAL DESIGN PRIOR TO INSTALLATION BY PROJECT STRUCTURAL DESIGNER.
3.NORRIS DESIGN IS NOT RESPONSIBLE FOR STRUCTURAL DESIGN AND CALCULATIONS.
4.CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR REVIEW AND APPROVAL PRIOR TO FABRICATION AND INSTALLATION.
CABANA FOOTER
SCALE: 3/4" = 1'-0"
T.O.PIER
SEE ARCH.BASE PLATE AND ANCHOR
BOLTS PER CABANA MFR. W/
NON-SHINK GROUT AS REQ'D.
20" MIN. DIA. "SONOTUBE"
FORMED CONCRETE PIER (VFY.
SIZE COMPATIBILITY W/
CABANA MFR. ANCHOR BOLT
LAYOUT); INCREASE SIZE IF
REQ'D FOR 3" MIN. CLEAR AT
ALL BOLTS
4'-0"
(5)-#4 EA. WAY AT
BOTTOM OF FOOTING
ADDITIONAL #4 X 4'-0" MIN.
SLAB REINF. AT 45° TO EA.
COLUMN FACE
(6) #4 DOWELS EQUALLY
SPACED
#4 HOOPS @ 8" O.C.
ADDITIONAL HOOP (FOR 4"
O.C.) AT TOP OF PIER
10" MIN.
CONCRETE SLAB BY OTHERS, PER SITE
PLAN
4'-0" MIN.
TYPICAL SUBGRADE PREP.F.H.COLUMN PER CABANA MFR.
NOTES:
1.REFER TO THE GEOTECHNICAL REPORT FOR SPECIFIC CONDITIONS RELATED TO THIS DETAIL.
2.NORRIS DESIGN HAS PROVIDED THIS DETAIL FOR REFERENCE AND PRICING PURPOSES AT THE DIRECTION OF THE OWNER. THIS
STRUCTURAL FOOTING AND REINFORCEMENT HAS NOT BEEN ENGINEERED AND WILL REQUIRE STAMPED PLANS PREPARED BY A LOCALLY
LICENSED MONTANA ENGINEER. NORRIS DESIGN IS NOT RESPONSIBLE FOR THE PERFORMANCE OR INTEGRITY OF THIS STRUCTURAL
FOOTING DETAIL. VERIFY STRUCTURAL DESIGN PRIOR TO INSTALLATION BY PROJECT STRUCTURAL DESIGNER.
3.NORRIS DESIGN IS NOT RESPONSIBLE FOR STRUCTURAL DESIGN AND CALCULATIONS.
4.CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR REVIEW AND APPROVAL PRIOR TO FABRICATION AND INSTALLATION.
CABANA FOOTER
SCALE: 3/4" = 1'-0"
T.O.PIER
SEE ARCH.BASE PLATE AND ANCHOR
BOLTS PER CABANA MFR. W/
NON-SHINK GROUT AS REQ'D.
20" MIN. DIA. "SONOTUBE"
FORMED CONCRETE PIER (VFY.
SIZE COMPATIBILITY W/
CABANA MFR. ANCHOR BOLT
LAYOUT); INCREASE SIZE IF
REQ'D FOR 3" MIN. CLEAR AT
ALL BOLTS
4'-0"
(5)-#4 EA. WAY AT
BOTTOM OF FOOTING
ADDITIONAL #4 X 4'-0" MIN.
SLAB REINF. AT 45° TO EA.
COLUMN FACE
(6) #4 DOWELS EQUALLY
SPACED
#4 HOOPS @ 8" O.C.
ADDITIONAL HOOP (FOR 4"
O.C.) AT TOP OF PIER
10" MIN.
CONCRETE SLAB BY OTHERS, PER SITE
PLAN
4'-0" MIN.
TYPICAL SUBGRADE PREP.F.H.COLUMN PER CABANA MFR.
2 3