HomeMy WebLinkAbout007 Stormwater Design Report - BDC INTRODUCTION The Bozeman Design Center proposes to develop an existing building pad site located on Lot 1, Block 2, Ferguson Farm Subdivision. The proposed development consists of a two-story commercial building, adjacent sidewalk, parking and landscaping improvements. Existing stormwater infrastructure was installed with the overall subdivision street improvements in 2015. Additional infrastructure was completed in 2018 with the Block 2 parking lot improvements. Both stormwater design reports were referenced in this analysis to ensure adequate capacity in the subdivision and parking lot exist. The Block 2 drainage report has been updated as well. It is included with this site plan application. Within Block 2, Drainage Area 1 will drain to the subdivision’s retention pond at the north end of the subdivision. Drainage Areas 2, 3 and 4 will drain to the Block 2 parking lot retention ponds. The proposed building’s roof will drain to a new underground Stormtech SC-740 chamber system under the proposed parking stalls to the south of the building. Two dry wells were installed with the Block 2 parking lot improvements and stubbed out to the Lot 1 building pad. These existing dry wells and stubs are being abandoned with this project due to the influence of the high groundwater table in the lower 1 to 2 feet of the drywells. STORMWATER DESIGN The original Block 2 stormwater report calculated 2,755 cubic feet of runoff from the area outside of the proposed building pad that drains into the right of way (Drainage Area #1 in the original Block 2 stormwater report). With the revision of the Block 2 site plan for the Bozeman Design Center, the runoff from this drainage area increased to 2,821 cubic feet, which is within the allowable limit of the previously allocated amount of 2,840 cubic feet. (See updated Block 2 stormwater report included with this site plan application). Additionally, the drainage from the area that contributes to Retention Pond #2 located on the west side of the parking lot (Drainage Area #4 in the original Block 2 stormwater report) increased slightly due to site modifications for the Bozeman Design Center. The increase in stormwater drainage was from 1,224 to 1,326 cubic feet and is still within the originally allocated volume of the pond, which is 1,500 cubic feet. The existing previously-installed drywells (approximately 8 feet deep) are going to be abandoned in place due to the influence of the high groundwater table. Therefore, a Stormtech SC-740 chamber system is proposed to be installed under the parking stalls along the south side of the Bozeman Design Center to capture the runoff from the building. The Stormtech chamber systems are sized according to City of Bozeman Design Standards to capture and retain or detain the volume of the 10-year 2-hour storm event. The proposed Stormtech infiltration chambers are designed to detain stormwater runoff using the arch-shaped chambers and void space in the surrounding washed rock, while the runoff infiltrates into the ground. The footprint of these chambers will be over-excavated down to native gravels to remove any existing non-draining material beneath the chambers. This excavation will be back-filled with a well-draining gravel to ensure infiltration. The chambers were sized by applying an infiltration rate for gravel subgrades to the footprint area of the chambers to determine the discharge (infiltrate rate) from the system. The discharge rate was then compared to the proposed inflow rates from the contributing areas to the systems during the 10-year 2-hour storm event to determine the required detention volumes for each system. The gravel infiltration rate used for these sizing calculations was determined to be 6 minutes per inch (10 inches per hour) per Circular DEQ 4 Table 2.1-1. This infiltration rate is considered to be conservative for native gravels based on the engineering experience of C&H Engineering in Bozeman. Because the required volume when using the infiltration design was less than the Runoff Reduction Volume (i.e. the “half inch requirement”) the system was sized for the larger. The runoff reduction volume is 843 cubic feet and the proposed chamber system is 975 cubic feet. GROUNDWATER A groundwater monitoring well exists within the building pad. Groundwater measurements were taken in November 2021. Given a lack of monitoring data during peak runoff season, two feet was added to the November measurements to estimate a high groundwater table elevation. (Based on groundwater monitoring data for the nearby proposed Ferguson Farm II Subdivision to the east, two feet was chosen as an average fluctuation in groundwater elevation for this site.) The approximate high groundwater table elevation in the footprint of the proposed Stormtech chamber system is 4,828.80 feet and the bottom of Stormtech gravel elevation is 4,831.13 feet. Approximately 2.3 feet of separation between high groundwater table and bottom of Stormtech system is provided. APPENDIX A BOZEMAN DESIGN CENTER DRAINAGE AREA MAP APPENDIX B SUPPORTING CALCULATIONS RUNOFF VOLUME FROM DA#1 1. Calculate Area and Weighted C Factor Contributing Area C Area (ft 2 )C * Area Landscape 0.2 0 0 Hardscape 0.95 7092 6738 Total 7092 6738 A = Area (acres)0.16 C = Weighted C Factor 0.95 2. Calculate Required Volume Q = CIA V=7200Q C = Weighted C Factor 0.95 I = intensity (in/hr) 0.41 (10 yr, 2hr storm) A = Area (acres) 0.16 Q = RUNOFF (cfs)0.06 V = REQUIRED VOL (ft3)454 RUNOFF VOLUME FROM DA#2.0 1. Calculate Area and Weighted C Factor Contributing Area C Area (ft 2 )C * Area Landscape 0.2 0 0 Hardscape 0.95 7083 6728 Total 7083 6728 A = Area (acres)0.16 C = Weighted C Factor 0.95 2. Calculate Required Volume Q = CIA V=7200Q C = Weighted C Factor 0.95 I = intensity (in/hr) 0.41 (10 yr, 2hr storm) A = Area (acres) 0.16 Q = RUNOFF (cfs)0.06 V = REQUIRED VOL (ft3)454 RUNOFF VOLUME FROM DA#3.0 1. Calculate Area and Weighted C Factor Contributing Area C Area (ft 2 )C * Area Landscape 0.2 0 0 Hardscape 0.95 7130 6773 Total 7130 6773 A = Area (acres)0.16 C = Weighted C Factor 0.95 2. Calculate Required Volume Q = CIA V=7200Q C = Weighted C Factor 0.95 I = intensity (in/hr) 0.41 (10 yr, 2hr storm) A = Area (acres)0.16 Q = RUNOFF (cfs)0.06 V = REQUIRED VOL (ft3)457 Chamber A DA #1&2&3 REQUIRED VOLUME 1. Calculate Area and Weighted C Factor (Post-Development) Contributing Area DA C Area (ft 2)C * Area Hardscape 1&2&3 0.95 21305 20239 Landscape 1&2&3 0.20 0 0 Total 21305 20239 A = Area (acres)0.49 Storm C = Weighted C Factor 0.95 Return(yrs)Cf 2 to 10 1 2. Calculate Infiltration Rate 11 to 25 1.1 Existing Soil Condition =Gravel 26 to 50 1.2 Infiltration Rate (min/in) =6 Circular DEQ 4 (Table 2.1-1)50 to 100 0.25 Infiltration Rate (in/hour) =10 Infiltration Rate (ft/sec) =0.00023 Infiltration Area (sf) =499 Total Area (acres) =0.49 acres Weighted C =0.95 Discharge Rate (cfs) =0.12 cfs Duration(min)Duration (hrs) Intensity (in/hr)Qin (cfs)Runoff Volume Release Volume Required Storage (ft3)47 0.78 0.75 0.35 983 326 657.05 48 0.80 0.74 0.34 990 333 657.39 49 0.82 0.73 0.34 997 340 657.63 50 0.83 0.72 0.33 1004 347 657.77 51 0.85 0.71 0.33 1011 353 657.83 52 0.87 0.70 0.33 1018 360 657.79 53 0.88 0.69 0.32 1025 367 657.67 54 0.90 0.69 0.32 1032 374 657.47 55 0.92 0.68 0.31 1038 381 657.19 56 0.93 0.67 0.31 1045 388 656.83 Check the half inch requirement (per DSSP II.A.4) 1. Determine Area of Hardscape within Drainage Area #1&2 Contributing Area Area (ft 2) Hardscape 21305 2. Calculate 1/2" runoff volume over hardscape (aka Runoff Reduction Volume [RRV] as calculated in Montana Post- Construction Storwater BMP Manual - Equation 3-1) RRV = [P*Rv*A]/12 P = Water quality rainfall depth 0.50 inches Rv = Dimensionless runoff coefficient 0.95 0.05 + 0.9*I I = Percent impervious cover (decimal)1.00 decimal A = Entire drainage area 0.49 acres RRV = Runoff Reduction Volume 0.0194 acre-ft RRV = Runoff Reduction Volume 843 cubic feet DRAINAGE AREA # 1 ROOF DOWNSPOUT PIPE ROUTED TO INFILTRATION SYSTEM #1 1. Summary of Roof Area and C Factor Contributing Area DA # C Area (ft 2)C * Area Hardscape 1 0.95 7092 6738 Total 7092 6738 A = Area (acres)0.16 C = Weighted C Factor 0.95 2. Calculate Tc (Time to Concentration) Tc Total = 5.0 (Assume 5 minute minimum) 3. Calculate Flow (Rational Formula) Q = CIA C = Weighted C Factor 0.95 (calculated above) I = 0.78 Tc-0.64 (in/hr)3.83 (25-yr storm) A = area (acres) 0.16 (calculated above) Q 25-yr Flow Rate (cfs)=0.59 MANNING'S EQUATION FOR PIPE FLOW (PROVIDED CAPACITY) Pipe: Downspout #1 INPUT D= 6 inches d= 5.63 inches Mannings Formula n= 0.013 mannings 57.7 degrees Q=(1.486/n)ARh2/3S1/2 S= 0.01 slope in/in R=A/P A=cross sectional area P=wetted perimeter V=(1.49/n)Rh2/3S1/2 S=slope of channel Q=V x A n=Manning's roughness coefficient Solution to Mannings Equation Area,ft2 Wetted Perimeter, ft Hydraulic Radius, ft velocity ft/s flow, cfs PVC 0.013 0.19 1.32 0.15 3.28 0.63 PE (<9"dia) 0.015 PE (>12"dia) 0.02 PE(9-12"dia) 0.017 CMP 0.025 ADS N12 0.012 HCMP 0.023 Conc 0.013 Manning's n-values d  D DRAINAGE AREA # 2 ROOF DOWNSPOUT PIPE ROUTED TO INFILTRATION SYSTEM #1 1. Summary of Roof Area and C Factor Contributing Area DA # C Area (ft 2)C * Area Hardscape 2 0.95 7083 6728 Total 7083 6728 A = Area (acres)0.16 C = Weighted C Factor 0.95 2. Calculate Tc (Time to Concentration) Tc Total = 5.0 (Assume 5 minute minimum) 3. Calculate Flow (Rational Formula) Q = CIA C = Weighted C Factor 0.95 (calculated above) I = 0.78 Tc-0.64 (in/hr)3.83 (25-yr storm) A = area (acres) 0.16 (calculated above) Q 25-yr Flow Rate (cfs)=0.59 MANNING'S EQUATION FOR PIPE FLOW (PROVIDED CAPACITY) Pipe: Downspout #1 INPUT D= 6 inches d= 5.63 inches Mannings Formula n= 0.013 mannings 57.7 degrees Q=(1.486/n)ARh2/3S1/2 S= 0.01 slope in/in R=A/P A=cross sectional area P=wetted perimeter V=(1.49/n)Rh2/3S1/2 S=slope of channel Q=V x A n=Manning's roughness coefficient Solution to Mannings Equation Area,ft2 Wetted Perimeter, ft Hydraulic Radius, ft velocity ft/s flow, cfs PVC 0.013 0.19 1.32 0.15 3.28 0.63 PE (<9"dia) 0.015 PE (>12"dia) 0.02 PE(9-12"dia) 0.017 CMP 0.025 ADS N12 0.012 HCMP 0.023 Conc 0.013 Manning's n-values d  D DRAINAGE AREA # 3 ROOF DOWNSPOUT PIPE ROUTED TO INFILTRATION SYSTEM #1 1. Summary of Roof Area and C Factor Contributing Area DA # C Area (ft 2)C * Area Hardscape 3 0.95 7130 6773 Total 7130 6773 A = Area (acres)0.16 C = Weighted C Factor 0.95 2. Calculate Tc (Time to Concentration) Tc Total = 5.0 (Assume 5 minute minimum) 3. Calculate Flow (Rational Formula) Q = CIA C = Weighted C Factor 0.95 (calculated above) I = 0.78 Tc-0.64 (in/hr)3.83 (25-yr storm) A = area (acres) 0.16 (calculated above) Q 25-yr Flow Rate (cfs)=0.59 MANNING'S EQUATION FOR PIPE FLOW (PROVIDED CAPACITY) Pipe: Downspout #1 INPUT D= 6 inches d= 5.63 inches Mannings Formula n= 0.013 mannings 57.7 degrees Q=(1.486/n)ARh2/3S1/2 S= 0.01 slope in/in R=A/P A=cross sectional area P=wetted perimeter V=(1.49/n)Rh2/3S1/2 S=slope of channel Q=V x A n=Manning's roughness coefficient Solution to Mannings Equation Area,ft2 Wetted Perimeter, ft Hydraulic Radius, ft velocity ft/s flow, cfs PVC 0.013 0.19 1.32 0.15 3.28 0.63 PE (<9"dia) 0.015 PE (>12"dia) 0.02 PE(9-12"dia) 0.017 CMP 0.025 ADS N12 0.012 HCMP 0.023 Conc 0.013 Manning's n-values d  D APPENDIX C STORMTECH MAINTENANCE PLAN An company 2 THE MOST ADVANCED NAME IN WATER MANAGEMENT SOLUTIONS TM ECCENTRICHEADER MANHOLEWITHOVERFLOWWEIR STORMTECHISOLATOR ROW OPTIONAL PRE-TREATMENT OPTIONAL ACCESS STORMTECH CHAMBERS  )(