Loading...
HomeMy WebLinkAbout015 A2.03 ROOF PLANA3.01 2 CLCL EE 11 11 3 3 CONNECT ROOF DRAIN TO DRAIN PIPE BELOW BB 6 6 2 2 8 8 5 5 10 10 CL2 CL2 CC 7 7 DD 4 4 9 9 ROOF ACCESS HATCH ROOF ACCESS HATCH 1/4" / 12"1/4" / 12"A3.01 5 A3.01 6 1 1 12 12 AA FF CONNECT ROOF DRAIN TO DRAIN PIPE BELOW A3.01 3 A3.01 1 A3.01 4 1/4" / 12"3/8" / 12"1/2" / 12"1/2" / 12"1/4" / 12"3/8" / 12" SHEET PROJECT NUMBER 81211 Gallatin Rd. Suite E Bozeman, Montana 59718 406.587.9968 studiohdesigninc.comPRINTED ON:PROJECT #:FILE PATH:PROJECT NAME:DRAWN BY:CHECKED BY:THESE DRAWINGS ARE THE ORIGINAL UNPUBLISHED WORK OF THE ARCHITECT AND MAY NOT BE DUPLICATED OR USED WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT.REVISIONS ISSUED ISSUE DATE:5/27/2022 12:22:15 PMC:\Users\SHD9\Documents\777 Boardwalk_DD_r2021_kkellerUY7HU.rvtA2.04 202005 ROOF PLAN777 BOARDWALKA2.04202005777 BOARDWALK6/1/20226/1/2022 SITE PLAN RE-SUBMITTALBOZEMAN, MONTANAFERGUSON FARMN GENERAL NOTES - ROOF PLANS 1 PROVIDE WALKWAY PADS TO ENSURE A PROTECTED PATH OF TRAVEL BETWEEN AND AROUND ALL MECHANICAL EQUIPMENT, ACCESS POINTS, AND WINDOW WASHING LOCATIONS. 2 MAINTAIN ± 4" THICK R30 RIGID INSULATION AT ROOF DRAIN LOCATIONS. 3 MAINTAIN MINIMUM SLOPE OF 3/8" PER FOOT AT MAIN ROOF AREAS. 4 MAINTAIN MINIMUM SLOPE OF 1/4" PER FOOT AT CRICKETS AND TAPERED INSULATION INTERSECTIONS. 5 OVERFLOW DRAINS ARE TO BE 2" MINIMUM HIGHER THAN PRIMARY ROOF DRAINS. 6 REFER TO STRUCTURAL DRAWINGS FOR SLOPING STRUCTURE. SHEET NOTES - ROOF PLAN 1 SHEET NOTE 1/8" = 1'-0"A2.04 1 ROOF PLAN