Loading...
HomeMy WebLinkAbout007 A0.01 GENERAL INFORMATIONHUFFINE LN RESORT DRBOARDWALK AVE.VALLEY COMMONS DR FIELD ST. 0 A101 1 A101 1 1t 1i CASEWORK SYMBOL DOOR SYMBOL MATCH LINE ELEVATION DETAIL BUILDING GRID LINES 1i MECH. EQUIP. SYMBOL XX PLUMBING SYMBOL 1 REVISION CLOUD 1 A101 SIM SECTION A101 1 1 1 1 INTERIOR ELEVATION 3' - 2"3' - 2" 6' - 4" DIMENSION STRING CONTROL POINT Room name 101 ROOM LABEL 1i WALL ASSEMBLY SYMBOL WINDOW SYMBOL EX-01 ?IN-01 EXT. MATERIAL SYMBOL INT. MATERIAL SYMBOL 1 1 APPLIANCE SYMBOL ACCESSORY SYMBOL SYMBOLS NORTH ARROW DRAWING TITLE AREA REFERENCE REFERENCE NO. SHEET NO. REFERENCE NO. SHEET NO. REFERENCE NO. & SHEET PROJECT NORTH DRAWING SCALE SHEET NO. REFERENCE NO. REVISION CLOUD REVISION NO. REFERENCE NO. SHEET NO. REFERENCE NO. SHEET NO. WORK POINT OR CONTROL POINT ROOM NO. A2.1 / 2 PROJECT INFORMATION PROJECT SITE: 777 BOARDWALK AVENUE BOZEMAN, MT 59718 LEGAL: FERGUSON FARM SUB, S10, T02 S, R05 E, BLOCK 2, LOT 1, 1.4851 ACRES, PLAT J-563 REGULATORY BUILDING CODES: (ICC) -INTERNATIONAL BUILDING CODE - 2018 (IBC) -NATIONAL ELECTRIC CODE - 2017 (NFPA 70) -INTERNATIONAL MECHANICAL CODE - 2018 (IMC) -UNIFORM PLUMBING CODE - 2018 (UPC) -INTERNATIONAL ENERGY CONSERVATION CODE - 2018 (IECC) -INTERNATIONAL FUEL GAS CODE - 2018 (IFGC) BUILDING CODES (NFPA) -NFPA 70 NATIONAL ELECTRICAL CODE - 2017 (NEC) BUILDING CODES (STATE) -INTERNATIONAL BUILDING CODE - 2018 (IBC) BUILDING CODES (MUNICIPAL) -INTERNATIONAL BUILDING CODE - 2018 (IBC) ACCESSIBILITY -2010 ADA STANDARDS FOR ACCESSIBILITY DESIGN (FEDERAL) -ICC A117.1 - 2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES -INTERNATIONAL BUILDING CODE - 2018 (IBC) ZONING: CITY OF BOZEMAN ZONE DISTRICT: B-2, COMMUNITY BUSINESS DISTRICT FIRE SPRINKLERS: YES, NFPA 13 W/ AUTOMATIC ALARM ACTIVATION (MIN. REQUIRED) BUILDING CONSTRUCTION TYPE: V-B BUILDING OCCUPANCY TYPES: B - BUSINESS, M - MERCANTILE BUILDING OCCUPANT LOAD: 295 (SEE SHEET A0.06) ALLOWABLE BUILDING HEIGHT (FLAT ROOF) : 50'-0" ACTUAL BUILDING HEIGHT: 50'-0" LOT SIZE: 1.4851 ACRES OR 64,691 SF F.A.R.: ___________________________ BUILDING AREA (NET S.F.): MAIN LEVEL: 12,861 SF 2ND LEVEL: 12,873 SF 3RD LEVEL: 13,978 SF TOTAL: 39,712 SF PROJECT SCOPE THIS PROJECT IS A 3-STORY SHELL BUILDING, WITH BUSINESS & MECHANT SPACE ON MAIN FLOOR AND OFFICE SPACE ON 2ND & 3RD FLOORS -NO RESIDENTIAL, SEE OCCUPANCY TYPE -NO AFFORDABLE HOUSING, NO RESIDENTIAL -NO PARKLAND, NO RESIDENTIAL PARKING CALCULATIONS: SEE CIVIL DRAWINGS & MASTER PLAN PARKING MECH. FOR FULL CALCULATIONS ADA CERTIFICATION: THIS ACKNOWLEDGES THAT THE FOLLOWING PROJECT WAS DESIGNED BY STUDIO H DESIGN, INC WITH FULL KNOWLEDGE THAT THE CITY OF BOZEMAN BUILDING DIVISION WILL NOT REVIEW FOR COMPLIANCE WITH, NOT IS RESPONSIBLE FOR ENFORCEMENT OF THE FEDERAL AMERICANS WITH DISABILITIES ACT OF 1990, THE REHABILITATION ACT OF 1973, THE FAIR HOUSING AMENDMENTS ACT OF 1988, TITLE 49, CHAPTER 2, COMMONLY KNOWN AS THE MONTANA HUMAN RIGHTS ACT, OR OTHER SIMILAR FEDERAL, STATE, OR LOCAL LAWS THAT MANDATE ACCESSIBILITY TO COMMERICAL CONSTRUCTION OR MULTIFAMILY HOUSING. SHEET PROJECT NUMBER 81211 Gallatin Rd. Suite E Bozeman, Montana 59718 406.587.9968 studiohdesigninc.comPRINTED ON:PROJECT #:FILE PATH:PROJECT NAME:DRAWN BY:CHECKED BY:THESE DRAWINGS ARE THE ORIGINAL UNPUBLISHED WORK OF THE ARCHITECT AND MAY NOT BE DUPLICATED OR USED WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT.REVISIONS ISSUED ISSUE DATE:5/27/2022 12:21:57 PMC:\Users\SHD9\Documents\777 Boardwalk_DD_r2021_kkellerUY7HU.rvtA0.01 202005 GENERAL INFORMATION777 BOARDWALKA0.01202005777 BOARDWALK6/1/20226/1/2022 SITE PLAN RE-SUBMITTALBOZEMAN, MONTANAFERGUSON FARMH HIGH H.B. HOSE BIB H.C. HOLLOW CORE HCP HANDICAPPED HDWR HARDWARE HDWD HARDWOOD H.M. HOLLOW METAL HORIZ HORIZONTAL HR HOUR HT HEIGHT HVAC HEATING, VANTILATION AND COOLING H.W. HOT WATER I.D. INSIDE DIAMETER INCL INCLUDING INSUL INSULATION INT INTERIOR JAN JANITOR JST JOIST JT JOINT KIT KITCHEN LAM LAMINATE LAV LAVATORY L.F. LINEAL FEET L.H. LEFT HAND LKR LOCKER L.R. LIVING ROOM LT LIGHT LVR LOUVER MATL MATERIAL MAX MAXIMUM M.B. MACHINE BALL MECH MECHANICAL MEMB MEMBRANE MUL MULLION MET METAL MTD MOUNTED MFR MANUFACTURER M.R. MOISTURE RESISTANT MH MANHOLE M.O. MASONRY OPENING MIN MINIMUM MISC MISCELLANEOUS MIR MIRROR NOM NOMINAL NO NUMBER N.I.C. NOT IN CONTRACT N NORTH SYS SYSTEM SYM SYMMETRICAL SW SWITCH SUSP SUSPENDED STRUCT STRUCTURAL STOR STORAGE STL STEEL STD STANDARD SSK SERVICE SINK S.S.D. SEE STRUCTURAL DRAWINGS S.S. STAINLESS STEEL SQ SQUARE SPEC SPECIFICATION SLDG SLIDING SIP STRUCTURAL INSULATED PANEL SIM SIMILAR SHT SHEET SHR SHOWER SH SHELF SEP SEPARATION OR SEPARATE SECT SECTION SCHED SCHEDULE S.C. SOLID CORE S.A.D. SEE ARCHITECTURAL DRAWINGS S SOUTH T TREAD T.O.P. TOP OF PARAPET TOIL TOILET THR THRESHOLD THK THICKOR THICKNESS TER TERRAZZO TEMP TEMPERED OR TEMPERATURE T.B. TOWEL BAR TEL TELEPHONE T.O.D. TOP OF DRAIN T.O.C. TOP OF CURB T&G TONGUE AND GROVE T.O.S. TOP OF SLAB T.P.D. TOILET PAPER DISPENSER T.S. TOP OF STEEL TV TELEVISION TYP. TYPICAL T.O.W. TOP OF WALL UR URINAL U.O.N. UNLESS OTHERWISE NOTED UNF UNFINISHED VERT VERTICLE VEST VESTIBLE VOL VOLUME V.I.F. VERIFY IN FIELD WIN WINDOW WD WOOD W.C. WATER CLOSET W/O WITHOUT W.O. WITHOUT W.H. WATER HEATER W/ WITH W WEST $ AND < ANGLE @ AT # NUMBER (E) EXISTING AB ANCHOR BOLT A/C AIR CONDITIONING ACOUS ACOUSTICAL ADJ ADJUSTABLE ACT ACOUSTICAL TILE A.F.F. ABOVE FINISH FLOOR A.C. ASPHALTIC CONCRETE ALT ALTER OR ALTERNATE ALUM ALUMINUM ANOD ANODIZED A.P. ACCESS PANEL APPROX APPROXIMATE ARCH ARCHITECTURAL ASPH ASPHALT BITUM BITUMINOUS BLDG BUILDING BLK BLOCK BLKG BLOCKING BM BEAM BOT BOTTOM BR BEDROOM BD BOARD BSMT BASEMENT B.U.R. BUILT UP ROOFING CAB CABINET CNTR COUNTER CARP CARPET CTR CENTER C.B. CATCH BASIN COL COLUMN CEM CEMENT C.T. CERAMIC TILE CER CERAMIC CONC CONCRETE C.I. CAST IRON CTSK COUNTERSUNK CLG CEILING COND CONDITION OR CONDENSER CLO CLOSET CLRC CLEAR CONN CONNECTION C.M.U CONCRETE MASONRY UNIT C.W. COLD WATER CONST CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CORR CORRIDOR D DEEP OR DEPTH DBL DOUBLE DET DETAIL D.F. DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DISP DISPENSER DN DOWN D.O. DOOR OPENING DR DOOR DS DOWNSPOUT D.S.P. DRY STANDPIPE DWG DRAWING DWR DRAWER EXST EXISTING E.O.S. EDGE OF SLAB EA EACH EXP EXPANSION EJ EXPANSION JOINT EQ EQUAL EL ELEVATION ELEC ELECTRICAL EQUIP EQUIPMENT ELEV ELEVATION EXPO EXPOSED EMER EMERGENCY E.W. EACH WAY ENCL ENCLOSRE E.W.C. ELECTRIC WATER COOLER EXT EXTERIOR E EAST F.A. FIRE ALARM FLR FLOOR F.D. FLOOR DRAWIN FDN FOUNDATION FLUOR FLUORESCENT F.E. FIRE EXTINGUISHER F.E.C. FIRE EXTINGUISHER CABINET F.O.C. FACE OF CONRETE F.G. FINISH GRADE F.H.C. FIRE HOSE CABINET F.O.F. FACE OF FINISH FIN FINISH FLASH FLASHING F.O.M. FACE OF MASONRY F.O.S. FACE OF STUD FPRF FIREPROOF FR FRAME FS FULL SIZE FUT FUTURE FT FOOT OR FEET FURR FURRING OR FURRED FTG FOOTING GA GAUGE GALV GALVANIZED G.B. GYPSUM BOARD G.I. GALVANIZED IRON GL GLASS OR GLAZING GND GROUND GR GRADE SHEET LIST ARCHITECTURAL A0.00 COVER SHEET A0.01 GENERAL INFORMATION A0.02 3D VIEWS A0.03 3D VIEWS A0.04 AREA PLANS A0.05 OCCUPANCY CLASS & FRR A0.06 OCCUPANT LOAD A2.01 FLOOR PLAN - MAIN LEVEL A2.02 FLOOR PLAN - 2ND LEVEL & ELEVATOR PLAN A2.03 FLOOR PLAN - 3RD LEVEL A2.04 ROOF PLAN A3.01 EXTERIOR ELEVATIONS A3.02 TRANSPARENCY/ SIGNAGE / WEATHER PROT. A3.03 EXTERIOR MATERIAL BOARD A4.01 BUILDING SECTIONS TRASH ENCLOSURE T0.01 TRASH ENCLOSURE - ARCHITECTURAL VICINITY MAP GENERAL NOTES - DIMENSIONING 1 ALL DIMENSIONS ARE TO FACE OF STRUCTURE (F.O.S.) UNLESS OTHERWISE NOTED. 2 DO NOT SCALE FROM DRAWINGS. 3 ANY INCONSISTENCIES OR UNFORSEEN CONDITIONS TO BE REVIEWED BY THE ARCHITECT PRIOR TO PRECEEDING WITH CONSTRUCTION. 4 ALL DOORS AND WINDOWS DIMENSIONED TO CENTERLINE OF CLEAR OPENING UNLESS OTHERWISE NOTED. 5 ALL NON-DIMENSIONED DOORS SHALL BE OFFSET FROM THE HINGE-SIDE WALL TO ALLOW FOR (2) 2X4 STUDS AT THE JAMB (U.O.N). 6 ALL NON-DIMENSIONED WINDOWS TO BE FLUSH TO ADJOINING WALL UNLESS OTHERWISE NOTED. 7 ALL CASEWORK DIMENSIONED TO FACE OF FINISH. GENERAL NOTES - PROJECT 1 THE GENERAL CONDITIONS OF THE CONTRACT OUTLINED BY THE MOST RECENT EDITION OF THE AMERICAN INSTITUTE OF ARCHITECTS ARE HEREBY INCORPORATED INTO THESE DRAWINGS. SAID "GENERAL CONDITIONS" SHALL GOVERN THE WORK OF ALL CONTRACTORS UNDER THIS CONTRACT. 2 ALL WORK SHALL COMPLY WITH ALL APPLICABLE CODES, ORDINANCES AND STANDARDS OF THE VARIOUS TRADES AND MANUFACTURERS. ALL MATERIALS SHALL BE NEW UNLESS OTHERWISE NOTED OR APPROVED BY THE OWNER. 7 ANY VARIANCE FROM THE PLANS AND SPECIFICATIONS SHALL BE VERIFIED WITH THE OWNER AND ARCHITECT PRIOR TO BEGINNING WORK. 9 THE OWNER SHALL MAINTAIN FIRE AND LIABILITY INSURANCE. 10 DATUM ELEVATION 100'-0" CORRESPONDS TO ELEVATION 6" ABOVE FINISH GRADE. 11 LANDSCAPE WORK TO BE DONE BY OTHERS AND APPROVED BY OWNER. 12 PROVIDE SUBSURFACE DRAINAGE PER GEOTECHNICAL SOILS REQUIREMENTS. 13 CONTRACTOR SHALL PROVIDE, ERECT AND MAINTAIN ALL TEMPORARY BARRIERS AND GUARDS, AND ALL TEMPORARY SHORING AND BRACING AS REQUIRED BY ALL CITY AND STATE REGULATIONS. 14 CONTRACTOR SHALL PROVIDE ADEQUATE WEATHER PROTECTION FOR THE BUILDING AND ITS CONTENTS DURING THE COURSE OF WORK. 15 CONTRACTOR TO PROVIDE TEMPORARY POWER POLE AND METER FOR THE DURATION OF THE WORK. CONTRACTOR TO MAINTAIN TEMPORARY LIGHTS AS REQUIRED FOR THE DURATION OF THE WORK. 16 CONTRACTOR SHALL PROVIDE TEMPORARY SANITARY FACILITIES AS TO LEAST IMPACT NEIGHBORS AND AS DIRECTED BY CITY REGULATIONS. 17 CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES - WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. 18 ALL PLANS, DESIGNS AND DRAWINGS SHALL REMAIN THE LEGAL PROPERTY OF STUDIO H DESIGN, INC. AND ARE NOT TO BE COPIED OR REPRODUCED WITHOUT EXPRESSED WRITTEN APPROVAL. 3 CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND JOB SITE CONDITIONS BEFORE COMMENCING WORK AND SHALL REPORT ANY DISCREPANCIES TO THE ARCHITECT. 4 USE WRITTEN DIMENSIONS. DO NOT SCALE DRAWINGS. WHERE NO DIMENSION IS PROVIDED, CONSULT THE ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. 5 GENERAL CONTRACTOR TO COORDINATE ARCHITECTURAL DRAWINGS WITH MECHANICAL, ELECTRICAL, AND PLUMBIING. 6 ALL MATERIALS AND FINISHES ARE TO BE AS SPECIFIED, OR PRE-APPROVED EQUAL. 8 CONTRACTOR IS TO USE WATER-RESISTANT GYPSUM WALL BOARD IN ALL WET SPACES (RESTROOMS, JANITORIAL AREAS, MECHANICAL/PLUMBING ROOMS, ETC.) 19 CONTRACTOR SHALL PROVIDE AS-BUILT DRAWINGS, SHOWING ANY CHANGES TO PLANS, ELEVATIONS, SYSTEMS, DIMENSIONING, ETC. GENERAL NOTES - MISCELLANEOUS 1 SOUND INSULATION REQUIRED IN BATHROOM AND BEDROOM INTERIOR WALLS. 2 WATER HEATERS SHALL BE STRAPPED OR HAVE A RIGID CONNECTION TO AN ADJACENT WALL. 3 GUARDRAILS AND HANDRAILS SHALL BE STRONG ENOUGH TO RESIST A 200 POUND POINT LOAD IN ANY DIRECTION. 4 PROVIDE 60 INCH MIN. A.F.F. NON-ABSORBENT WALL ADJACENT TO SHOWERS AND BATHTUBS, AND APPROVED SHATTER-RESISTANT MATERIALS FOR SHOWER ENCLOSURE. 5 PROVIDE 1.6 GAL LOW FLUSH WATER CLOSETS FOR ALL LOCATIONS. 6 THE MINIMUM THICKNESS OF CONCRETE SLABS SUPPORTED DIRECTLY ON THE GROUND SHALL NOT BE LESS THAN 3-1/2 INCHES. 7 VALLEY FLASHINGS SHALL NOT BE LESS THAN 0.019-INCH (0.48 MM) (NO. 26 GALVANIZED SHEET GAGE) CORROSION-RESISTANT METAL INSTALLED OVER A MINIMUM 36-INCH WIDE (914 MM) UNDERLAYMENT CONSISTING OF ONE LAYER OF NO. 72 ASTM CAP SHEET RUNNING THE FULL LENGTH OF THE VALLEY. ABBREVIATIONS F.A.R. : 39,712 / 64,691 = 0.6:1 (NO MAXIMUM FOR B-2)