HomeMy WebLinkAbout105 IR2.1 - IRRIGATION DETAILS - MCPE 20211027Scale:
Site Plan Submittal Date: NOVEMBER 12, 2021
SITE PLAN SUBMITTALTHE HOMESTEAD AT BUFFALO RUN
5400 FOWLER LANES23, T02 S, R05 E, N2SW4SW4, CITY OF BOZEMAN, GALLATIN COUNTY, MONTANA.
Revision 2 Date:JULY 6, 2022
CONTROL WIRE BUNDLE OR TWO
WIRE COMMUNICATION CABLE (PER
SPECIFICATIONS)
SPRINKLER HEAD
LATERAL PIPING OR
DRIP LINE HEADER.
TRENCH 12
FINISH
GRADE
BACKFILL MATERIAL (TYP.)
18"
12"
MARKER TAPE
MAINLINE
NOTE: REFER TO TECHNICAL
SPECIFICATIONS FOR MINIMUM
TRENCH WIDTHS.
B
A
ROUGH GRADE
C
NOTE:
·ALL SLEEVE MATERIAL PER IRRIGATION SCHEDULE, SIZE AS NOTED ON
PLAN.
·INSTALL SLEEVES IN SIDE-BY-SIDE CONFIGURATION WHERE MULTIPLE
SLEEVES ARE TO BE INSTALLED. SPACE SLEEVES 4" TO 6" APART. DO
NOT STACK SLEEVES VERTICALLY.
·CONTRACTOR TO COORDINATE WITH FLATWORK INSTALLER TO BRAND A
"V" IN SIDEWALK OR CURB AT BOTH ENDS OF SLEEVE CROSSING.
·SLEEVING THROUGH OR UNDER RETAINING WALLS, PLANTER WALLS, POND
LINING, OR WATER QUALITY AREAS SHALL BE COORDINATED WITH CIVIL
WORK AT APPROXIMATE LOCATIONS SHOWN.
PAVED SURFACE
CURB AND GUTTER
(IF APPLICABLE)
2" PVC PIPE SLEEVE MARKER -
INSTALL AT BOTH ENDS OF EACH
SLEEVE LOCATION AND EXTEND AT
LEAST 3' ABOVE GRADE. SPRAY
EXPOSED PORTION OF MARKER WITH
GREEN FLUORESCENT PAINT. REMOVE
AT FINAL INSTALL.
SEAL ENDS OF SLEEVE WITH
CLOTH DUCT TAPE (TYPICAL)
PVC SLEEVING (TYPICAL)
24" MIN.
12" MIN.
36" MIN.
IRRIGATION SLEEVING 13TYPICAL
GROUNDING MUST MEET ALL MANUFACTURER'S REQUIREMENTS. IN ADDITION,
GROUNDING PLATE DESIGN CONSISTS OF ONE VERTICAL 8-FOOT COPPER CLAD
GROUNDING ROD (AT LEAST EIGHT FEET FROM THE EQUIPMENT), AND ONE COPPER
GROUNDING PLATE PER 40 STATIONS REQUIRING GROUNDING. INSTALL GROUNDING
PLATE HORIZONTALLY, THREE FEET DEEP AND 15' FROM THE GROUNDING ROD.
SHOULD MULTIPLE RODS/PLATES BE REQUIRED, THEY SHALL BE PLACED A MINIMUM
OF 3 LINEAR FEET FROM EACH OTHER. PERFORM CADWELD CONNECTION TO
GROUNDING ROD(S) AND PLACEMENT OF GROUNDING PLATE(S) IN OWNER'S
PRESENCE PRIOR TO BACKFILL. REFER TO ASIC STANDARDS FOR MORE
INFORMATION.
FINISH GRADE
SATELLITE CONTROLLER(S)
#6 CONTINUOUS SOLID BARE COPPER WIRE (TYPICAL)
CADWELD GT1161G "ONE SHOT" WELD
58" x 8FT COPPER-CLAD GROUNDING ROD
#6 CONTINUOUS SOLID BARE COPPER WIRE (TYPICAL)
COPPER GROUNDING PLATE 4"x96"x0.0626"
GROUND ENHANCEMENT MATERIAL PER
MANUFACTURER'S RECOMMENDATIONS
1'
8'15'
3'
14CONTROLLER GROUNDING
TWO-WIRE SYSTEM - Pedestal Mount
FINISH GRADE
RECTANGULAR VALVE BOX WITH
EXTENSION - BRAND "MV" INTO
VALVE BOX LID. REFER TO
TECHNICAL SPECIFICATIONS.
FIPTxFIPT SCH. 80 PVC UNIONS (2)
PRESSURE MAINLINE
34" CRUSHED GRAVEL SUMP - 2 C.F.
Y-STARINER
15Y-STRAINER
12"
4" SAND
MARKER TAPE
8"
4" SAND
R
Know what's below.Call before you dig.orwww.UNCC2.org DIRECTORYIRRIGATION SCHEDULE IR1.0IRRIGATION NOTES IR1.0IRRIGATION PLANS IR1.1IRRIGATION DETAILS IR2.0 - IR2.1
13949 W. Colfax Ave,, Suite 260 Lakewood, Colorado 80401
o: 303.980.5327 www.hydrosystemskdi.com
Irrigation Consulting & Water Management NTS
IR2.1 - IRRIGATION DETAILS
WATER USE CHART -PARK
NOTE:
·DIAMETERS OF FITTINGS AND NIPPLES SHALL
EQUAL ROTOR INLET DIAMETER.
·SET ROTOR PERPENDICULAR TO FINISH GRADE.
·APPLY TEFLON TAPE ALL PVC MALE THREADED
FITTINGS.
24"
6"
SET LIP AT FINSHED GRADE
CURB AND GUTTER, SIDEQALK OR HARD
SURFACE WHERE APPLICABLE
HI-POP GEAR DRIVEN ROTOR
MIPTxFIPT SCH. 40 PVC ELL (2)
12" SCH. 80 PVC NIPPLE
MIPTxFIPT SCH. 40 PVC 90 ELL
PVC SUPPLY LINE WITH SCH. 40
SLIPxFIPT PVC FITTING
30-60 DEG
HI-POP GEAR DRIVEN ROTOR 16PVC C1