Loading...
HomeMy WebLinkAbout104 IR2.0 - IRRIGATION DETAILS - MCPE20211027Scale: Site Plan Submittal Date: NOVEMBER 12, 2021 SITE PLAN SUBMITTALTHE HOMESTEAD AT BUFFALO RUN 5400 FOWLER LANES23, T02 S, R05 E, N2SW4SW4, CITY OF BOZEMAN, GALLATIN COUNTY, MONTANA. Revision 2 Date:JULY 6, 2022 3" SET BOTTOM OF CAP AT GRADE CURB & GUTTER, SIDEWALK OR HARD SURFACE WHERE APPLICABLE POP-UP SPRAY HEAD 12" MALExBARB ELL 12" DIA. POLYETHYLENE SWING PIPE (4 L.F. MAXIMUM LENGTH) 12" MALExBARB ADAPTER NOTE: ·SET HEAD PERPENDICULAR TO FINISH GRADE. ·APPLY TEFLON TAPE TO MALE PVC THREADED FITTINGS. ·DOUBLE CLAMP 112" & 2" DIAMETER FITTINGS. PVC LATERAL SWING W/ LINE SIZEx12" SLIPxFIPT FITTING POP-UP SPRAY HEAD 1SWING PIPE - PVC NOTE: ·DIAMETERS OF FITTINGS AND NIPPLES SHALL EQUAL ROTOR INLET DIAMETER. ·SET ROTOR PERPENDICULAR TO FINISH GRADE. ·APPLY TEFLON TAPE TO ALL PVC MALE THREADED FITTINGS. 6" 30-60 DEG SET LIP AT FINISHED GRADE CURB AND GUTTER, SIDEWALK OR HARD SURFACE WHERE APPLICABLE GEAR DRIVEN ROTOR MIPxFIP SCH. 40 PVC ELL (2) 12" SCH. 80 PVC NIPPLE MIPxFIP SCH. 40 PVC 90 ELL PVC LATERAL PIPING WITH SCH. 40 SLIPxFIPT PVC FITTING GEAR DRIVEN ROTOR 2SWING JOINT - PVC FINISH GRADE APPLY TEFLON TAPE TO ALL THREADED NIPPLES 3" 2" 10" ROUND VALVE BOX BRAND "QC" INTO VALVE BOX LID. REFER TO TECHNICAL SPECIFICATIONS. 34" CRUSHED GRAVEL SUMP -FILL BOX TO WITHIN 2" OF BOTTOM OF QCV LID 1" BRASS NIPPLE LENGTH AS REQUIRED LINE SIZE BRASS COUPLING 12"x12" REBAR STABILIZING STAKE TYPICAL TWO SIDES PER QUICK COUPLING VALVE LOCATION LASCO #G 13S-212 UNITIZED SWING JOINT W/ BRASS INSERT STABILIZER ELBOW. PROVIDE WITH 1" MIPT INLET PRESSURE MAINLINEx1" PVC SERVICE TEE - SOLVENT WELD OR GASKETED FITTING REFER TO SPECIFICAIONS QUICK COUPLING VALVE QUICK COUPLING VALVE 4LASCOSWING - TYPICAL FINISH GRADE 3" 12' MIN. 48" MIN. TIPPING RAIN SENSOR PE-54 COMMUNICATION CABLE RUN WITHIN POST ASSEMBLY. 112" DIAMETER SCH. 40 GALVANIZED STEEL POST W/ 112" GALVANIZED FIPT CAP PE-89 COMMUNICATION CABLE EXTEND CABLE TO RAIN BIRD PULSE DECODER WITHIN CONTROLLER ASSEMBLY REFER TO IRRIG. PLAN FOR LOCATION. 112" FxF GALVANIZED STEEL 90 ELL 3" WEATHER SENSOR 6POLE MOUNTED - Rain Counter FINISH GRADE APPLY TEFLON TAPE TO ALL MALE THREADED PVC FITTINGS AND ALL NIPPLES 34" CRUSHED GRAVEL SUMP 1 CU. FT. 2" VALVE MARKER 10" ROUND VALVE BOX - BRAND THE LETTER "D' IN LID. REFER TO TECHNICAL SPECIFICATIONS. 2" CL 200 PVC ACCESS SLEEVE - LENGTH AS REQUIRED 34" FxF SCH. 80 PVC 90 ELL (2) 34"xCL PVC NIPPLE SCH. 80 (2) 34"x6" SCH. 80 GALVANIZED STEEL NIPPLE 34" BRASS GLOBE VALVE 34" MxF SCH. 40 PVC 90 ELL SOIL BLANKET COVERING SUMP 34"x4" PVC NIPPLE SCH. 80 34" CRUSHED GRAVEL SUMP. SEE TECHNICAL SPECIFICATIONS FOR SUMP SIZE PVC PRESSURE MAINLINE. REFER TO TRENCH DETAIL. MANUAL DRAIN VALVE 8TYPICAL FINISH GRADE 2" 3" 10" ROUND VALVE BOX. BRAND "GV" ON LID OF VALVE BOX. REFER TO TECHNICAL SPECIFICATIONS. GATE VALVE W/ CROSS HANDLE AND SOLID WEDGE DISC. 34" CRUSHED GRAVEL SUMP - FILL BOX TO WITHIN 2" OF TOP OF 6" PVC ACCESS SLEEVE∅ 6" CLASS 200 PVC SLEEVE BOTTOM TO BE NOTCHED AND CONTACT TOP OF PRESSURE MAINLINE PVC PRESSURE MAINLINE SCH. 40 PVC MALE ADAPTER (2) - SIZE TO EQUAL GATE VALVE DIAMETER UNDISTURBED SOIL 9GATE VALVE 2.5" & SMALLER - X-HANDLE 0.5% SLOPE A NOTES: ·CONTRACTOR TO GROUND AND PROVIDE SURGE PROTECTION FOR CONTROLLER IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND GROUND ROD(S) SHOWN. ·CONTROLLER GROUNDING SHALL COMPLY W/ MANUFACTURER'S SPECIFICATIONS. ·INSTALL A DISCONNECT SWITCH AND 120 VOLT GFIC RECEPTACLE WITHIN PEDESTAL. ·ALL ELECTRICAL WORK TO CONFORM TO LOCAL CODE. 6" 18" 6"6" PLAN VIEW 5" 1" CLOSEST IRRIGATED AREA 120 VOLT SERVICE GFI & POWER SWITCH CONTROLLER INSTALL 4" HT. SELF ADHESIVE VINYL LETTERING CORRESPONDING WITH CONTROLLER # ON OUTSIDE SURFACE OF ENCLOSURE DOOR. CONTROL WIRES - NEATLY BUNDLE WIRING & SECURE W/ LOCKING WIRE TIES 34" NON-METALLIC LIQUIDTITE CONDUIT W/ MALE ADAPTERS (2) AND LOCK RINGS, WASHERS CONCRETE PAD FINISH GRADE 58"x8' COPPER - CLAD GROUNDINGROD W/ BRONZE CLAMP & 10" ROUND VALVE BOX (TYPICAL) #6 BARE COPPER GROUNDING WIRE 1" PVC CONDUIT W/ SWEEP ELL - GROUND WIRE3" PVC CONDUIT W/ SWEEP ELL - CONTROL WIRES PROVIDE 48" LENGTH OF ALL SPARE WIRES WITHIN PEDESTAL, NEATLY COILED. 34" PVC CONDUIT W/ SWEEP ELL - 120v SERVICE PREFABRICATED ENCLOSURE FRONT VIEW EXTERNAL SIDE VIEW 5ELECTRIC CONTROLLER PEDESTAL - FRONT OPENING - TYPICAL A Y-STRAINER QUICK COUPLERVALVE GATE VALVE WELL HEAD PITLESSADAPTER WELLREFER TO DETAIL NO.23 Y-STRAINER REFER TO DETAIL NO.6 QUICK COUPLER VALVE REFER TO DETAIL NO.12 GATE VALVE REFER TO DETAIL NO.7 CONTROLLER CONTROLLER POWER AND WIRING, REFER TO CONTROLLER & WELL PUMP ELECTRIC PLANS WELL / IRRIGATION CONNECTION SECTION - TYPICAL IMPORTANT TYPICAL SECTION OF THE IRRIGATION CONNECTION TO THE WELL AND ELECTRICAL /CONTROLLER COMPONENTS ARE SCHEMATIC ONLY. ALL COMPONENTS SHOWN ARE TO BE FIELD STAKED BY THE CONTRACTOR AND LOCATIONS APPROVED BY LANDSCAPE ARCHITECT PRIOR TO ANY INSTALLATION. ELECTRICALPEDESTAL PRESSURE GUAGE, REFER TO ELECTRICAL PRESSURE TRANSDUCER & PRES. PLANS REFER TO ELECTRICAL PLAN TRANSDUCER 7 NOTE: DIAMETERS OF BALL VALVES, PVC FITTINGS AND NIPPLES SHALL EQUAL ELECTRIC CONTROL VALVE DIAMETER. VALVE BOXES SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO ADJACENT SIDEWALKS AND HARD SURFACES WHERE APPLICABLE. APPLY TEFLON TAPE TO ALL MALE THREADED FITTINGS AND THREADED NIPPLES. PVC LATERAL - 45 ELL TO SPECIFIED DEPTH SCH. 40 PVC REDUCING MALE ADAPTER RECTANGULAR VALVE BOX. BRAND LID WITH CONTROLLER & STATION #. REFER TO TECHNICAL SPECIFICATIONS. CENTER BOX OVER ASSEMBLY. PROVIDE 12" CONTINUOUS COILS OF ALL "MAINTENANCE" SPARE CONTROL/COMMON WIRING WITHIN VALVE BOX PVC BALL VALVE - FIPTxFIPT 34" CRUSHED GRAVEL SUMP - FILL BOX TO BOTTOM OF VALVE BODY SCH. 80 PVC NIPPLE - LENGTH AS REQUIRED SERVICE TEE - SOLVENT WELD OR GASKETED FITTING - REFER TO SPECIFICATIONS CONTROL WIRE BUNDLE ELECTRIC CONTROL VALVE 4" FINISH GRADE 3ELECTRIC CONTROL VALVE 24V - PVC Lateral FINISH GRADE RECTANGULAR VALVE BOX WITH EXTENSION - BRAND "MV" INTO VALVE BOX LID. REFER TO TECHNICAL SPECIFICATIONS. SLIPxMIPT SCH. 40 PVC ADAPTER (2) PRESSURE MAINLINE 34" CRUSHED GRAVEL SUMP - 2 C.F. ELECTRIC MASTER CONTROL VALVE MASTER VALVE 1024V - Small - Typical NO FITTINGS INCLUDING REDUCER BUSHINGS, TEES, ELLS, ETC, SHALL BE INSTALLED WITHIN "METER RUN" DISTANCE. DIAMETER OF FLOW SENSOR TEE AND "METER RUN" PIPING SHALL BE EQUAL. NO REDUCER BUSHINGS, ADAPTERS, ETC. SHALL BE INSTALLED WITHIN FLOW SENSOR TEE. DATA CABLE SPLICE CONSISTING OF WIRE NUTS AND PREFORMED SUPER SERVISEAL SPLICE KIT. FINISH GRADE RECTANGULAR VALVE BOX WITH EXTENSIONS AS REQUIRED. BRAND "FS" INTO VALVE BOX LID. REFER TO TECHNICAL TO TECHNICAL SPECIFICATIONS SPECIFICATIONS. VALVE BOX SHALL NOT REST DIRECTLY ON FLOW SENSOR CABLE. TEE STYLE FLOW SENSOR. REFER TO PLAN & SCHEDULE FOR SIZING, MANUFACTURER, & MODEL. DATA CABLE TO CONTROLLER SENSOR INPUTS PER MANUFACTURER RECOMMENDATION. PROVIDE ADDITIONAL CABLE WITHIN BOX TO ALLOW REMOVAL OF SENSING UNIT FROM BOX FOR MAINTENANCE PURPOSES. 3/4" GRAVEL SUMP - 2 CU. FT. PVC PRESSURE MAINLINE - REFER TO PLAN FOR DIAMETER. FLOW 10x PIPE DIA.5x PIPE DIA. METER RUN FLOW SENSOR 11VIA DATA CABLE - TEE STYLE R Know what's below.Call before you dig.orwww.UNCC2.org DIRECTORYIRRIGATION SCHEDULE IR1.0IRRIGATION NOTES IR1.0IRRIGATION PLANS IR1.1IRRIGATION DETAILS IR2.0 - IR2.1 13949 W. Colfax Ave,, Suite 260 Lakewood, Colorado 80401 o: 303.980.5327 www.hydrosystemskdi.com Irrigation Consulting & Water Management NTS IR2.0 - IRRIGATION DETAILS