HomeMy WebLinkAbout104 IR2.0 - IRRIGATION DETAILS - MCPE20211027Scale:
Site Plan Submittal Date: NOVEMBER 12, 2021
SITE PLAN SUBMITTALTHE HOMESTEAD AT BUFFALO RUN
5400 FOWLER LANES23, T02 S, R05 E, N2SW4SW4, CITY OF BOZEMAN, GALLATIN COUNTY, MONTANA.
Revision 2 Date:JULY 6, 2022
3"
SET BOTTOM OF CAP AT GRADE
CURB & GUTTER, SIDEWALK OR
HARD SURFACE WHERE
APPLICABLE
POP-UP SPRAY HEAD
12" MALExBARB ELL
12" DIA. POLYETHYLENE SWING
PIPE (4 L.F. MAXIMUM LENGTH)
12" MALExBARB ADAPTER
NOTE:
·SET HEAD PERPENDICULAR TO FINISH GRADE.
·APPLY TEFLON TAPE TO MALE PVC THREADED FITTINGS.
·DOUBLE CLAMP 112" & 2" DIAMETER FITTINGS.
PVC LATERAL SWING W/ LINE
SIZEx12" SLIPxFIPT FITTING
POP-UP SPRAY HEAD 1SWING PIPE - PVC
NOTE:
·DIAMETERS OF FITTINGS AND NIPPLES SHALL
EQUAL ROTOR INLET DIAMETER.
·SET ROTOR PERPENDICULAR TO FINISH GRADE.
·APPLY TEFLON TAPE TO ALL PVC MALE THREADED
FITTINGS.
6"
30-60 DEG
SET LIP AT FINISHED GRADE
CURB AND GUTTER, SIDEWALK OR HARD
SURFACE WHERE APPLICABLE
GEAR DRIVEN ROTOR
MIPxFIP SCH. 40 PVC ELL (2)
12" SCH. 80 PVC NIPPLE
MIPxFIP SCH. 40 PVC 90 ELL
PVC LATERAL PIPING WITH SCH.
40 SLIPxFIPT PVC FITTING
GEAR DRIVEN ROTOR 2SWING JOINT - PVC
FINISH GRADE
APPLY TEFLON TAPE TO ALL THREADED NIPPLES
3"
2"
10" ROUND VALVE BOX BRAND
"QC" INTO VALVE BOX LID.
REFER TO TECHNICAL
SPECIFICATIONS.
34" CRUSHED GRAVEL SUMP -FILL BOX TO WITHIN 2" OF
BOTTOM OF QCV LID
1" BRASS NIPPLE LENGTH AS REQUIRED
LINE SIZE BRASS COUPLING
12"x12" REBAR STABILIZING STAKE
TYPICAL TWO SIDES PER QUICK
COUPLING VALVE LOCATION
LASCO #G 13S-212 UNITIZED SWING
JOINT W/ BRASS INSERT STABILIZER
ELBOW. PROVIDE WITH 1" MIPT INLET
PRESSURE MAINLINEx1" PVC SERVICE TEE -
SOLVENT WELD OR GASKETED FITTING REFER
TO SPECIFICAIONS
QUICK COUPLING VALVE
QUICK COUPLING VALVE 4LASCOSWING - TYPICAL
FINISH GRADE
3"
12' MIN.
48" MIN.
TIPPING RAIN SENSOR
PE-54 COMMUNICATION
CABLE RUN WITHIN POST
ASSEMBLY.
112" DIAMETER SCH. 40
GALVANIZED STEEL POST W/
112" GALVANIZED FIPT CAP
PE-89 COMMUNICATION CABLE EXTEND
CABLE TO RAIN BIRD PULSE DECODER
WITHIN CONTROLLER ASSEMBLY REFER TO
IRRIG. PLAN FOR LOCATION.
112" FxF GALVANIZED STEEL 90 ELL
3"
WEATHER SENSOR 6POLE MOUNTED - Rain Counter
FINISH GRADE
APPLY TEFLON TAPE TO ALL MALE THREADED
PVC FITTINGS AND ALL NIPPLES
34" CRUSHED GRAVEL SUMP 1 CU. FT.
2" VALVE MARKER
10" ROUND VALVE BOX - BRAND THE
LETTER "D' IN LID. REFER TO
TECHNICAL SPECIFICATIONS.
2" CL 200 PVC ACCESS SLEEVE -
LENGTH AS REQUIRED
34" FxF SCH. 80 PVC 90 ELL (2)
34"xCL PVC NIPPLE SCH. 80 (2)
34"x6" SCH. 80 GALVANIZED STEEL NIPPLE
34" BRASS GLOBE VALVE
34" MxF SCH. 40 PVC 90 ELL
SOIL BLANKET COVERING SUMP
34"x4" PVC NIPPLE SCH. 80
34" CRUSHED GRAVEL SUMP. SEE
TECHNICAL SPECIFICATIONS FOR
SUMP SIZE
PVC PRESSURE MAINLINE. REFER
TO TRENCH DETAIL.
MANUAL DRAIN VALVE 8TYPICAL
FINISH GRADE
2"
3"
10" ROUND VALVE BOX. BRAND "GV"
ON LID OF VALVE BOX. REFER TO
TECHNICAL SPECIFICATIONS.
GATE VALVE W/ CROSS HANDLE AND
SOLID WEDGE DISC.
34" CRUSHED GRAVEL SUMP - FILL
BOX TO WITHIN 2" OF TOP OF 6"
PVC ACCESS SLEEVE∅
6" CLASS 200 PVC SLEEVE BOTTOM TO
BE NOTCHED AND CONTACT TOP OF
PRESSURE MAINLINE
PVC PRESSURE MAINLINE
SCH. 40 PVC MALE ADAPTER (2) - SIZE
TO EQUAL GATE VALVE DIAMETER
UNDISTURBED SOIL
9GATE VALVE
2.5" & SMALLER - X-HANDLE
0.5%
SLOPE
A
NOTES:
·CONTRACTOR TO GROUND AND PROVIDE SURGE
PROTECTION FOR CONTROLLER IN ACCORDANCE
WITH MANUFACTURER'S RECOMMENDATIONS AND
GROUND ROD(S) SHOWN.
·CONTROLLER GROUNDING SHALL COMPLY W/
MANUFACTURER'S SPECIFICATIONS.
·INSTALL A DISCONNECT SWITCH AND 120 VOLT GFIC
RECEPTACLE WITHIN PEDESTAL.
·ALL ELECTRICAL WORK TO CONFORM TO LOCAL
CODE.
6"
18"
6"6"
PLAN VIEW
5"
1"
CLOSEST
IRRIGATED
AREA
120 VOLT SERVICE GFI & POWER SWITCH
CONTROLLER
INSTALL 4" HT. SELF ADHESIVE VINYL LETTERING
CORRESPONDING WITH CONTROLLER # ON
OUTSIDE SURFACE OF ENCLOSURE DOOR.
CONTROL WIRES - NEATLY BUNDLE WIRING
& SECURE W/ LOCKING WIRE TIES
34" NON-METALLIC LIQUIDTITE CONDUIT W/ MALE
ADAPTERS (2) AND LOCK RINGS, WASHERS
CONCRETE PAD
FINISH GRADE
58"x8' COPPER - CLAD GROUNDINGROD W/ BRONZE CLAMP & 10" ROUND
VALVE BOX (TYPICAL)
#6 BARE COPPER GROUNDING WIRE
1" PVC CONDUIT W/ SWEEP ELL - GROUND WIRE3" PVC CONDUIT W/ SWEEP ELL - CONTROL WIRES
PROVIDE 48" LENGTH OF ALL SPARE WIRES
WITHIN PEDESTAL, NEATLY COILED.
34" PVC CONDUIT W/ SWEEP ELL - 120v SERVICE
PREFABRICATED ENCLOSURE
FRONT
VIEW
EXTERNAL
SIDE VIEW
5ELECTRIC CONTROLLER
PEDESTAL - FRONT OPENING - TYPICAL
A
Y-STRAINER QUICK COUPLERVALVE GATE VALVE
WELL HEAD
PITLESSADAPTER
WELLREFER TO DETAIL NO.23
Y-STRAINER
REFER TO DETAIL NO.6
QUICK COUPLER VALVE
REFER TO DETAIL NO.12
GATE VALVE
REFER TO DETAIL NO.7
CONTROLLER
CONTROLLER
POWER AND WIRING, REFER TO
CONTROLLER & WELL PUMP
ELECTRIC PLANS
WELL / IRRIGATION CONNECTION SECTION - TYPICAL
IMPORTANT
TYPICAL SECTION OF THE IRRIGATION CONNECTION TO
THE WELL AND ELECTRICAL /CONTROLLER
COMPONENTS ARE SCHEMATIC ONLY. ALL
COMPONENTS SHOWN ARE TO BE FIELD STAKED BY
THE CONTRACTOR AND LOCATIONS APPROVED BY
LANDSCAPE ARCHITECT PRIOR TO ANY INSTALLATION.
ELECTRICALPEDESTAL
PRESSURE
GUAGE, REFER TO ELECTRICAL
PRESSURE TRANSDUCER & PRES.
PLANS
REFER TO ELECTRICAL PLAN
TRANSDUCER
7
NOTE: DIAMETERS OF BALL VALVES, PVC FITTINGS AND NIPPLES SHALL
EQUAL ELECTRIC CONTROL VALVE DIAMETER. VALVE BOXES SHALL BE
INSTALLED PARALLEL OR PERPENDICULAR TO ADJACENT SIDEWALKS AND
HARD SURFACES WHERE APPLICABLE. APPLY TEFLON TAPE TO ALL MALE
THREADED FITTINGS AND THREADED NIPPLES.
PVC LATERAL - 45 ELL TO
SPECIFIED DEPTH
SCH. 40 PVC REDUCING
MALE ADAPTER
RECTANGULAR VALVE BOX. BRAND LID
WITH CONTROLLER & STATION #. REFER
TO TECHNICAL SPECIFICATIONS. CENTER
BOX OVER ASSEMBLY.
PROVIDE 12" CONTINUOUS COILS OF ALL
"MAINTENANCE" SPARE CONTROL/COMMON
WIRING WITHIN VALVE BOX
PVC BALL VALVE - FIPTxFIPT
34" CRUSHED GRAVEL SUMP - FILL BOX
TO BOTTOM OF VALVE BODY
SCH. 80 PVC NIPPLE - LENGTH AS
REQUIRED
SERVICE TEE - SOLVENT WELD
OR GASKETED FITTING - REFER
TO SPECIFICATIONS
CONTROL WIRE BUNDLE
ELECTRIC CONTROL VALVE
4"
FINISH GRADE
3ELECTRIC CONTROL VALVE
24V - PVC Lateral
FINISH GRADE
RECTANGULAR VALVE BOX WITH
EXTENSION - BRAND "MV" INTO
VALVE BOX LID. REFER TO
TECHNICAL SPECIFICATIONS.
SLIPxMIPT SCH. 40 PVC ADAPTER (2)
PRESSURE MAINLINE
34" CRUSHED GRAVEL SUMP - 2 C.F.
ELECTRIC MASTER CONTROL
VALVE
MASTER VALVE 1024V - Small - Typical
NO FITTINGS INCLUDING REDUCER BUSHINGS, TEES,
ELLS, ETC, SHALL BE INSTALLED WITHIN "METER
RUN" DISTANCE. DIAMETER OF FLOW SENSOR TEE
AND "METER RUN" PIPING SHALL BE EQUAL. NO
REDUCER BUSHINGS, ADAPTERS, ETC. SHALL BE
INSTALLED WITHIN FLOW SENSOR TEE.
DATA CABLE SPLICE CONSISTING OF
WIRE NUTS AND PREFORMED SUPER
SERVISEAL SPLICE KIT.
FINISH GRADE
RECTANGULAR VALVE BOX WITH EXTENSIONS
AS REQUIRED. BRAND "FS" INTO VALVE BOX
LID. REFER TO TECHNICAL TO TECHNICAL
SPECIFICATIONS SPECIFICATIONS. VALVE BOX
SHALL NOT REST DIRECTLY ON FLOW SENSOR
CABLE.
TEE STYLE FLOW SENSOR. REFER
TO PLAN & SCHEDULE FOR SIZING,
MANUFACTURER, & MODEL.
DATA CABLE TO CONTROLLER SENSOR
INPUTS PER MANUFACTURER
RECOMMENDATION. PROVIDE ADDITIONAL
CABLE WITHIN BOX TO ALLOW REMOVAL
OF SENSING UNIT FROM BOX FOR
MAINTENANCE PURPOSES.
3/4" GRAVEL SUMP - 2 CU. FT.
PVC PRESSURE MAINLINE - REFER
TO PLAN FOR DIAMETER.
FLOW
10x PIPE DIA.5x PIPE DIA.
METER RUN
FLOW SENSOR 11VIA DATA CABLE - TEE STYLE
R
Know what's below.Call before you dig.orwww.UNCC2.org DIRECTORYIRRIGATION SCHEDULE IR1.0IRRIGATION NOTES IR1.0IRRIGATION PLANS IR1.1IRRIGATION DETAILS IR2.0 - IR2.1
13949 W. Colfax Ave,, Suite 260 Lakewood, Colorado 80401
o: 303.980.5327 www.hydrosystemskdi.com
Irrigation Consulting & Water Management NTS
IR2.0 - IRRIGATION DETAILS