Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
097 IR2.1 - IRRIGATION DETAILS - 20211027
Site Plan Submittal Date: NOVEMBER 12, 2021SITE PLAN SUBMITTALTHE HOMESTEAD AT BUFFALO RUN5400 FOWLER LANES23, T02 S, R05 E, N2SW4SW4, CITY OF BOZEMAN, GALLATIN COUNTY, MONTANA.Revision 1 Date:MAY 10, 20223"SET BOTTOM OF CAP AT GRADECURB & GUTTER, SIDEWALK ORHARD SURFACE WHEREAPPLICABLEPOP-UP SPRAY HEAD12" MALExBARB ELL12" DIA. POLYETHYLENE SWINGPIPE (4 L.F. MAXIMUM LENGTH)12" MALExBARB ADAPTERNOTE:·SET HEAD PERPENDICULAR TO FINISH GRADE.·APPLY TEFLON TAPE TO MALE PVC THREADED FITTINGS.·DOUBLE CLAMP 112" & 2" DIAMETER FITTINGS.PVC LATERAL SWING W/ LINESIZEx12" SLIPxFIPT FITTINGPOP-UP SPRAY HEAD1SWING PIPE - PVCNOTE:·SET HEAD PERPENDICULAR TO FINISH GRADE SWING.·FLEX PIPE SHALL BE ATTACHED TO BOTTOM SPRAY HEADINLET ONLY.·APPLY TEFLON TAPE TO ALL MALE PVC THREADEDFITTINGS AND NIPPLES.SET BOTTOM OF CAP AT GRADE3"CURB AND GUTTER, SIDEWALK OR HARDSURFACE WHERE APPLICABLE12" HI-POP SPRAY HEAD12" MALExBARB 90d ELL12" FLEX PIPE (6"-12" LENGTH)12" MALExBARB ADAPTERPVC LATERAL PIPING W/ SCH. 40 PVCLINE SIZEx12" SLIPxFIPT FITTING2HI-POP SPRAY HEADSWING PIPE - PVCNOTE:·DIAMETERS OF FITTINGS AND NIPPLES SHALLEQUAL ROTOR INLET DIAMETER.·SET ROTOR PERPENDICULAR TO FINISH GRADE.·APPLY TEFLON TAPE TO ALL PVC MALE THREADEDFITTINGS.6"30-60 DEGSET LIP AT FINISHED GRADECURB AND GUTTER, SIDEWALK OR HARDSURFACE WHERE APPLICABLEGEAR DRIVEN ROTORMIPxFIP SCH. 40 PVC ELL (2)12" SCH. 80 PVC NIPPLEMIPxFIP SCH. 40 PVC 90 ELLPVC LATERAL PIPING WITH SCH.40 SLIPxFIPT PVC FITTINGGEAR DRIVEN ROTOR3SWING JOINT - PVCNOTE:·DIAMETERS OF FITTINGS AND NIPPLES SHALLEQUAL ROTOR INLET DIAMETER.·SET ROTOR PERPENDICULAR TO FINISH GRADE.·APPLY TEFLON TAPE ALL PVC MALE THREADEDFITTINGS.24"6"SET LIP AT FINSHED GRADECURB AND GUTTER, SIDEQALK OR HARDSURFACE WHERE APPLICABLEHI-POP GEAR DRIVEN ROTORMIPTxFIPT SCH. 40 PVC ELL (2)12" SCH. 80 PVC NIPPLEMIPTxFIPT SCH. 40 PVC 90 ELLPVC SUPPLY LINE WITH SCH. 40SLIPxFIPT PVC FITTING30-60 DEGHI-POP GEAR DRIVEN ROTOR4PVCFINISH GRADEAPPLY TEFLON TAPE TO ALL THREADED NIPPLES3"2"10" ROUND VALVE BOX BRAND"QC" INTO VALVE BOX LID.REFER TO TECHNICALSPECIFICATIONS.34" CRUSHED GRAVEL SUMP -FILL BOX TO WITHIN 2" OFBOTTOM OF QCV LID1" BRASS NIPPLE LENGTH AS REQUIREDLINE SIZE BRASS COUPLING12"x12" REBAR STABILIZING STAKETYPICAL TWO SIDES PER QUICKCOUPLING VALVE LOCATIONLASCO #G 13S-212 UNITIZED SWINGJOINT W/ BRASS INSERT STABILIZERELBOW. PROVIDE WITH 1" MIPT INLETPRESSURE MAINLINEx1" PVC SERVICE TEE -SOLVENT WELD OR GASKETED FITTING REFERTO SPECIFICAIONSQUICK COUPLING VALVEQUICK COUPLING VALVE6LASCOSWING - TYPICALNOTE: MOUNT RAIN SENSOR RECEIVERPER CONTROLLER DETAIL.10' MIN.36" MIN.12" DIAMETER CONCRETE BASE - FORMW/ SONA-TUBE OR EQUAL. POST SHALLBE CENTERED WITHIN BASE.FINISH GRADE112" DIAMETER SCH. 40GALVANIZED STEEL POST112"x12" FxF SCH. 40 GALVANIZEDTEE W/ 112" MIPT PLUGWIRELESS RAIN SENSOR (MODEL PERSCHEDULE) - TOP OF SENSOR TO BEABOVE RAIN SHADOW OF BUILDINGGUTTERS, TREES AND/OR ANY OTHEROBSTRUCTIONSWEATHER SENSOR8POLE MOUNTED - WirelessPVC PRESSURE MAINLINEREFER TO IRRIGATIONSCHEDULENOTE:·CONCRETE PAD PENETRATIONS TO BE 1"LARGER THAN TUBING DIAMETER.·REFER TO ENCLOSURE DETAIL FORCONCRETE PAD DIMENSIONS.·DIAMETER OF FITTINGS, NIPPLE AND TUBINGSHALL EQUAL DIAMETER OF BACKFLOWPREVENTER UNLESS NOTED OTHERWISE.BRONZE UNION - SWxSW6" THICK CONCRETE PAD -LENGTH AS REQUIRED, 30" MIN.WIDTH. TOP OF SLAB TO BE 1"ABOVE FINISH GRADE.ADJUSTABLE CAST IRON STOPBOX - TYLER OR EQUALPROTECTIVE ENCLOSURE -REFER TO DETAILREDUCED PRESSUREBACKFLOW PREVENTERCxM ADAPTER (TWO REQUIRED)QUICK COUPLINGVALVE - INSTALL ASPER QCV DETAIL12"SOIL FILTER FABRIC COVERINGGRAVEL SUMPSTOP & DRAIN VALVE - LINE SIZE34" CRUSHED GRAVEL SUMP - 2 CU. FT.SERVICE LINE FROM WATER METER12"EQEQTYPE "K"RIGIDCOPPERBACKFLOW PREVENTER93/4" - 2" SYSTEMS WITH PVC CONNECTIONCLEQEQ6"16.25"6"YBFP MODEL/SIZE ENCLOSURE MODELXYFEBCO 825Y 34" & 1"SBBC-30AL 30" 42"FEBCO 825Y 112" & 2"SBBC-45AL 45"57"FEBCO 825YA 34" & 1"SBBC-22AL22''34"FEBCO 825YA 112" & 2"SBBC-30AL30" 42"NOTES:·PAD PENETRATIONS FOR BACKFLOW PREVENTER RISERS TO BE1" LARGER THAN RISER DIAMETER.·TOP SURFACE OF CONCRETE PAD SHALL BE 1" ABOVE FINISHGRADE.·INSTALL ENCLOSURE ANCHORS AS PER MANUFACTURER'SRECOMMENDATIONS.·PROVIDE OWNER WITH KEYED PADLOCK FOR ENCLOSURE.30"XCL1"5"EQ6"YEQ6"CLCONCRETE PADSTRONGBOX ENCLOSURE10STRONGBOX - 3/4" - 2" SYSTEMSBACKFLOW ENCLOSUREFINISH GRADEAPPLY TEFLON TAPE TO ALL MALE THREADEDPVC FITTINGS AND ALL NIPPLES34" CRUSHED GRAVEL SUMP 1 CU. FT.2" VALVE MARKER10" ROUND VALVE BOX - BRAND THELETTER "D' IN LID. REFER TOTECHNICAL SPECIFICATIONS.2" CL 200 PVC ACCESS SLEEVE -LENGTH AS REQUIRED34" FxF SCH. 80 PVC 90 ELL (2)34"xCL PVC NIPPLE SCH. 80 (2)34"x6" SCH. 80 GALVANIZED STEEL NIPPLE34" BRASS GLOBE VALVE34" MxF SCH. 40 PVC 90 ELLSOIL BLANKET COVERING SUMP34"x4" PVC NIPPLE SCH. 8034" CRUSHED GRAVEL SUMP. SEETECHNICAL SPECIFICATIONS FORSUMP SIZEPVC PRESSURE MAINLINE. REFERTO TRENCH DETAIL.MANUAL DRAIN VALVE11TYPICALFINISH GRADE2"3"10" ROUND VALVE BOX. BRAND "GV"ON LID OF VALVE BOX. REFER TOTECHNICAL SPECIFICATIONS.GATE VALVE W/ CROSS HANDLE ANDSOLID WEDGE DISC.34" CRUSHED GRAVEL SUMP - FILLBOX TO WITHIN 2" OF TOP OF 6"PVC ACCESS SLEEVE∅6" CLASS 200 PVC SLEEVE BOTTOM TOBE NOTCHED AND CONTACT TOP OFPRESSURE MAINLINEPVC PRESSURE MAINLINESCH. 40 PVC MALE ADAPTER (2) - SIZETO EQUAL GATE VALVE DIAMETERUNDISTURBED SOIL12GATE VALVE2.5" & SMALLER - X-HANDLENOTE: DIAMETERS OF BALL VALVES, PVC FITTINGS ANDNIPPLES SHALL EQUAL ELECTRIC CONTROL VALVEDIAMETER. VALVE BOXES SHALL BE INSTALLED PARALLELOR PERPENDICULAR TO ADJACENT SIDEWALKS AND HARDSURFACES WHERE APPLICABLE. APPLY TEFLON TAPE TOALL MALE THREADED FITTINGS AND THREADED NIPPLES.PVC LATERAL - 45 ELL TOSPECIFIED DEPTHSCH. 40 PVC REDUCINGMALE ADAPTERRECTANGULAR VALVE BOX. BRAND LID WITHCONTROLLER & STATION #. REFER TOTECHNICAL SPECIFICATIONS. CENTER BOXOVER ASSEMBLY.PVC BALL VALVE - FIPTxFIPT34" CRUSHED GRAVEL SUMP - FILL BOXTO BOTTOM OF VALVE BODYSCH. 80 PVC NIPPLE - LENGTH ASREQUIREDSERVICE TEE - SOLVENT WELDOR GASKETED FITTING - REFERTO SPECIFICATIONSELECTRIC CONTROL VALVE4"FINISH GRADETWO BLACK WIRES TO VALVE SOLENOIDDECODERDBR-6 (2)PROVIDE 60" CONTINUOUS COILS OF EXTRACABLE WIRING WITHIN VALVE BOX (PERDECODER) FOR MAINTENANCE PURPOSES.TWO-WIRE PATH TO NEXT DECODERTO EARTH GROUNDING LOCATIONINSTALLED PER ASIC GUIDELINES. REFERTO CONSTRUCTION NOTES FORFREQUENCY AND OTHER REQUIREMENTS.TWO-WIRE PATH TONEXT DECODERDBR-6 (2)DBR-6ELECTRIC CONTROL VALVE5TWO-WIRE SYSTEM - PVC PIPE0.5%SLOPEANOTES:·CONTRACTOR TO GROUND AND PROVIDE SURGEPROTECTION FOR CONTROLLER IN ACCORDANCEWITH MANUFACTURER'S RECOMMENDATIONS ANDGROUND ROD(S) SHOWN.·CONTROLLER GROUNDING SHALL COMPLY W/MANUFACTURER'S SPECIFICATIONS.·INSTALL A DISCONNECT SWITCH AND 120 VOLT GFICRECEPTACLE WITHIN PEDESTAL.·ALL ELECTRICAL WORK TO CONFORM TO LOCALCODE.6"18"6"6"PLAN VIEW5"1"CLOSESTIRRIGATEDAREA120 VOLT SERVICE GFI & POWER SWITCHCONTROLLERINSTALL 4" HT. SELF ADHESIVE VINYL LETTERINGCORRESPONDING WITH CONTROLLER # ONOUTSIDE SURFACE OF ENCLOSURE DOOR.CONTROL WIRES - NEATLY BUNDLE WIRING& SECURE W/ LOCKING WIRE TIES34" NON-METALLIC LIQUIDTITE CONDUIT W/ MALEADAPTERS (2) AND LOCK RINGS, WASHERSCONCRETE PADFINISH GRADE58"x8' COPPER - CLAD GROUNDINGROD W/ BRONZE CLAMP & 10" ROUNDVALVE BOX (TYPICAL)#6 BARE COPPER GROUNDING WIRE1" PVC CONDUIT W/ SWEEP ELL - GROUND WIRE3" PVC CONDUIT W/ SWEEP ELL - CONTROL WIRESPROVIDE 48" LENGTH OF ALL SPARE WIRESWITHIN PEDESTAL, NEATLY COILED.34" PVC CONDUIT W/ SWEEP ELL - 120v SERVICEPREFABRICATED ENCLOSUREFRONTVIEWEXTERNALSIDE VIEW7ELECTRIC CONTROLLERPEDESTAL - FRONT OPENING - TYPICALRKnow what's below.Call before you dig.orwww.UNCC2.orgDIRECTORYIRRIGATION SCHEDULE IR1.0IRRIGATION NOTES IR1.0IRRIGATION PLANS IR1.1 - IR1.6IRRIGATION DETAILS IR2.1 - IR2.313949 W. Colfax Ave,, Suite 260 Lakewood, Colorado 80401o: 303.980.5327 www.hydrosystemskdi.comIrrigation Consulting & Water ManagementNTSIR2.1 - IRRIGATION DETAILS