Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
080 C403_NEUtilityPlan
DYH WVWV S S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8S 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8W 8S8S8S8S8S8S8S8S8S8S8S8S8S8SDYHDYH DYH 8W8W8W8W8W8W8W8W8W8W8W8W8W8W8W8WS S S 8W8W8W8W8W8W8W8W8W8W8W8W8W8WWSWSSSWSWSSSWSWSSSWSWSSSWSWSSSWSWSSSWSWSSSWS WS SS SS SS SSD D D D E E E E E E E G BP E EEE UTIL UTILUTILUTILUTILUTILUTILUTILUTILUTILUTILUTIL BP BP NG NG NG NG NG NG NG NG NG NG NG NG NG NG NG NG NG NG NG NG NG NGUTILUTILUTIL NGNGNGNGNGNGNGNGNGBPBPBPBPBPBPBPBPBPBPBPBPBPNG BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BPBPBPBP BP BP BP BP BP BP BP BPBPWS WSFIRE WSFIRE WSFIREFIRE8S8S8S8S 8S8S8S8S8S8S8S8S8S8S30' PEDESTRIAN & UTILITY EASEMENT BUFFALO RUN AVENUEKURK DRIVE PROPOSED BUILDING C PROPOSED BUILDING 9 A/B PROPOSED BUILDING 10 A/B PROPOSED BUILDING 11 A/B PROPOSED BUILDING 12 A/B PROPOSED BUILDING 13 A/B PROPOSED BUILDING 14 A/B PROPOSED BUILDING M PROPOSED BUILDING G PROPOSED BUILDING I PROPOSED BUILDING F 10' PUBLIC UTILITY EASEMENT 10' PUBLIC UTILITY EASEMENT VERIFY SCALE! THESE PRINTS MAY BE REDUCED. LINE BELOW MEASURES ONE INCH ON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY! 2022COPYRIGHT © MORRISON-MAIERLE, INC., SHEET NUMBER PROJECT NUMBER DRAWING NUMBER DATEDESCRIPTIONNO.BY N:\6475\005 - BUFFALO RUN - SITE PLAN\ACAD\SHEETS\6475.005 - C400 UTILITY PLAN SHEETS.DWG PLOTTED BY:LEE HAGEMAN ON Jul/27/2022 REVISIONS DRAWN BY: DSGN. BY: APPR. BY: DATE: Q.C. REVIEW DATE: BY: 2880 Technology Blvd West Bozeman, MT 59718 406.587.0721 www.m-m.net engineers surveyors planners scientists MorrisonMaierle THE HOMESTEAD AT BUFFALO RUN BOZEMAN MONTANA NE UTILITY PLAN (2 OF 5) 6475.005 19 C402 DAH LRH MEE 07/2022 30 6015300 SCALE IN FEET SITE PLAN SUBMITTAL - REV 3 07/2022 PROPOSED FIRE SERVICE, (TYP) PROPOSED SANITARY SEWER MANHOLE, (TYP)PROPOSED 8" SEWER MAIN, (TYP) PROPOSED 8" WATER MAIN, (TYP) PROPOSED ELECTRIC UTILITY METER, (TYP) PROPOSED FIRE HYDRANT, (TYP) PROPOSED NATURAL GAS LINE, (TYP) PROPOSED NATURAL GAS LINE, (TYP) PROPOSED BURIED POWER LINE, (TYP) PROPOSED BURIED POWER LINE, (TYP) MATCH LINE C404MATCH LINE C4011 1 1 1 1 1 Know what's below. before you dig.Call R 1 2 07/26/2022 KEY NOTES ANTICPATED 1.25" DOMESTIC WATER METER AND VALVES LOCATED WITHIN CRAWL SPACE (VERIFY WITH ARCHITECT/MECHANICAL) ANTICPATED 2" DOMESTIC WATER METER AND VALVES LOCATED WITHIN CRAWL SPACE (VERIFY WITH ARCHITECT/MECHANICAL) SEWER SERVICES SHALL BE 4" DIAMETER UNLESS OTHERWISE NOTED 1 1.ALL IMPROVEMENTS ON THIS PROJECT SHALL BE COMPLETED IN ACCORDANCE WITH THE MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS, 7TH EDITION DATED APRIL 2021 (MPWSS); THE CITY OF BOZEMAN MODIFICATIONS TO THE MPWSS; AND THE PROJECT SPECIFICATIONS. 2.THE CONTRACTOR SHALL RESTORE ALL ROADWAY SURFACES TO EQUAL OR BETTER CONDITION THAN EXISTED PRIOR TO EXCAVATION AS DETERMINED BY AGENCY, OWNER, AND/OR ENGINEER. 3.ASPHALT, CONCRETE CURB, AND SIDEWALK SHALL BE SAW CUT OR NEAT CUT AS APPROVED BY AGENCY AND/OR ENGINEER. 4.ALL TEXT AND FEATURES SHOWN SHADED ARE EXISTING. SEE SHEET C017 FOR MORE COMPLETE DEPICTION OF EXISTING CONDITIONS. 5.THE LOCATION, DEPTH, AND SIZE OF THE EXISTING UTILITIES SHOWN ON THESE PLANS IS APPROXIMATE. THE CONTRACTOR SHALL VERIFY THE EXISTENCE, LOCATION, DEPTH AND SIZE OF THE UTILITIES PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY DAMAGE TO THE EXISTING FACILITIES DUE TO FAILURE TO LOCATE OR PROPERLY PROVIDE PROTECTION WHEN LOCATION IS KNOWN. 6.ALL WATER VALVES OWNED AND OPERATED BY THE CITY OF BOZEMAN SHALL BE OPERATED BY AUTHORIZED CITY OF BOZEMAN PERSONNEL ONLY. 7.SEWER AND WATER CONNECTIONS SHALL BE PERFORMED BY A LICENSED PLUMBER. 8.GENERAL CONTRACTOR TO COORDINATE DRY UTILITY AND IRRIGATION REQUIREMENTS. 9.DOMESTIC WATER SERVICE SIZES PROPOSED (VERIFY WITH ARCHITECTURAL/MECHANICAL) DUPLEX = 1.25"; COMMUNITY CENTER = 2"; BUILDINGS A-F & H = 4"; BUILDINGS G, J, K, L &N = 2"; BUILDINGS I, M, & O = 1.25" GENERAL NOTES: 2 PROPOSED 4" FIRE SERVICE PROPOSED 4" FIRE SERVICE 1 3 PROPOSED 4" WATER SERVICEPROPOSED 4" WATER SERVICE PROPOSED FIRE HYDRANT, (TYP) EXISTING FIRE HYDRANT (PRESERVE) PROPOSED FIRE HYDRANT, (TYP) PROPOSED SEWER SERVICE, (TYP) 3 PROPOSED SEWER SERVICE, (TYP) NEW 8" GATE VALVE. CONNECT TO EXISTING WATER MAIN UTILITY ROOM INSIDE DIMS.: 14.04' X 6.19' UTILITY ROOM INSIDE DIMS.: 14.04' X 7.19' UTILITY ROOM INSIDE DIMS.: 14.04' X 7.19' PROPOSED WATER SERVICE PROPOSED TEMPORARY WATER EASEMENT AND TEMPORARY BLOWOFF HYDRANT (TYP) PROPOSED UNDERGROUND STORMWATER TREATMENT SYSTEM (TYP) PROPOSED LID POND WITH CURB CUT AND RIP RAP AS SHOWN PROPOSED STORM DRAIN MAIN (TYP)