Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
079 C402_SWUtilityPlan
[][][][][][][][][][][][][][][][][][][] W 8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S8W8W8W8W8W8W8W8W8W8W8W8W8W8W8W8WDYHSDYHDYHS15S15S15S15S 8W 8W 8W 8W 8W 8W 8W 8W 8W 6W16W16W16W16W16W16W16W16W16W16W16W16W16W16W6WDYHS 8W 8W 8W 8W 8W 8W 8W 8W 8W 8WSS SS SS D D D 18SD18SD18SD18SD18SD18SD18SD18SD18SD18SD18SD18SD18SDD E E E E E G NG NG NG NG NG NG NGNGNGNGNGNGNGNGNGNGNGBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBPBP BP BPBPBPBPBPBPBPBPBPBPBPBPBPBPBP UTILUTILUTILUTILUTILUTIL UTILUTILUTILUTILUTIL NG NG NGUTILUTILUTILUTILUTILUTIL BPBP BP BPBPBPBP DYHWS WSFIREFIRE SSSSSSSS8S8S8S8S8S8S8S8S8S8S8S8S8S8S8S6WUD15S15S15S15S15S15S15S15S15S15S15SIR IR IR 8W8W8W 8W 8W 8W 8W 8W 8W6W WS WS EXISTING 20' PUBLIC STREET AND UTILITY EASEMENT EXISTING 10' PUBLIC UTILITY EASEMENT PROPOSED BUILDING D PROPOSED BUILDING B PROPOSED BUILDING H PROPOSED BUILDING A 30' PUBLIC UTILITY EASEMENT 10' PUBLIC UTILITY EASEMENT 10' PUBLIC UTILITY EASEMENT 30' PUBLIC UTILITY EASEMENT 30' PUBLIC UTILITY EASEMENT 30' WATER LINE EASEMENT VERIFY SCALE! THESE PRINTS MAY BE REDUCED. LINE BELOW MEASURES ONE INCH ON ORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY! 2022COPYRIGHT © MORRISON-MAIERLE, INC., SHEET NUMBER PROJECT NUMBER DRAWING NUMBER DATEDESCRIPTIONNO.BY N:\6475\005 - BUFFALO RUN - SITE PLAN\ACAD\SHEETS\6475.005 - C400 UTILITY PLAN SHEETS.DWG PLOTTED BY:LEE HAGEMAN ON Jul/27/2022 REVISIONS DRAWN BY: DSGN. BY: APPR. BY: DATE: Q.C. REVIEW DATE: BY: 2880 Technology Blvd West Bozeman, MT 59718 406.587.0721 www.m-m.net engineers surveyors planners scientists MorrisonMaierle THE HOMESTEAD AT BUFFALO RUN BOZEMAN MONTANA SW UTILITY PLAN (3 OF 5) 6475.005 20 C403 DAH LRH MEE 07/2022 30 6015300 SCALE IN FEET SITE PLAN SUBMITTAL - REV 3 07/2022 PROPOSED 4" WATER SERVICE PROPOSED 8" WATER MAIN, (TYP) PROPOSED FIRE HYDRANT, (TYP) PROPOSED ELECTRIC UTILITY METER, (TYP) PROPOSED GAS UTILITY SERVICE, (TYP) PROPOSED 4" FIRE SERVICE PROPOSED NATURAL GAS LINE, (TYP) EXISTING 6" DRAIN PIPE (PRESERVE) MATCH LINE C401 MATCH LINE C404Know what's below. before you dig.Call R 07/26/2022 KEY NOTES ANTICPATED WATER METER AND VALVES LOCATED WITHIN CRAWL SPACE (VERIFY WITH ARCHITECT/MECHANICAL) SEWER SERVICES SHALL BE 4" DIAMETER UNLESS OTHERWISE NOTED 1 1.ALL IMPROVEMENTS ON THIS PROJECT SHALL BE COMPLETED IN ACCORDANCE WITH THE MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS, 7TH EDITION DATED APRIL 2021 (MPWSS); THE CITY OF BOZEMAN MODIFICATIONS TO THE MPWSS; AND THE PROJECT SPECIFICATIONS. 2.THE CONTRACTOR SHALL RESTORE ALL ROADWAY SURFACES TO EQUAL OR BETTER CONDITION THAN EXISTED PRIOR TO EXCAVATION AS DETERMINED BY AGENCY, OWNER, AND/OR ENGINEER. 3.ASPHALT, CONCRETE CURB, AND SIDEWALK SHALL BE SAW CUT OR NEAT CUT AS APPROVED BY AGENCY AND/OR ENGINEER. 4.ALL TEXT AND FEATURES SHOWN SHADED ARE EXISTING. SEE SHEET C017 FOR MORE COMPLETE DEPICTION OF EXISTING CONDITIONS. 5.THE LOCATION, DEPTH, AND SIZE OF THE EXISTING UTILITIES SHOWN ON THESE PLANS IS APPROXIMATE. THE CONTRACTOR SHALL VERIFY THE EXISTENCE, LOCATION, DEPTH AND SIZE OF THE UTILITIES PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY DAMAGE TO THE EXISTING FACILITIES DUE TO FAILURE TO LOCATE OR PROPERLY PROVIDE PROTECTION WHEN LOCATION IS KNOWN. 6.ALL WATER VALVES OWNED AND OPERATED BY THE CITY OF BOZEMAN SHALL BE OPERATED BY AUTHORIZED CITY OF BOZEMAN PERSONNEL ONLY. 7.SEWER AND WATER CONNECTIONS SHALL BE PERFORMED BY A LICENSED PLUMBER. 8.GENERAL CONTRACTOR TO COORDINATE DRY UTILITY AND IRRIGATION REQUIREMENTS. 9.DOMESTIC WATER SERVICE SIZES PROPOSED (VERIFY WITH ARCHITECTURAL/MECHANICAL) DUPLEX = 1.25"; COMMUNITY CENTER = 2"; BUILDINGS A-F & H = 4"; BUILDINGS G, J, K, L &N = 2"; BUILDINGS I, M, & O = 1.25" GENERAL NOTES: FOWLER LANE IMPROVEMENTS SHOWN ARE PART OF SEPARATE OFFSITE SUBMITTAL DATED DECEMBER 30, 2021 2 PROPOSED FIRE HYDRANT, (TYP) PROPOSED 4" WATER SERVICE PROPOSED 4" FIRE SERVICE UTILITY ROOM INSIDE DIMS.: 14.04' X 6.73' UTILITY ROOM INSIDE DIMS.: 14.04' X 7.39' PROPOSED UNDERGROUND STORMWATER TREATMENT SYSTEM (TYP) PROPOSED STORM DRAIN MAIN (TYP)