HomeMy WebLinkAbout017- L2.1 IRRIGATION PLANDURSTAN ROAD
NAHORNIAKBOZEMAN, MTDURSTAN ROADXIRRIGATION NOTES
2. Mainline piping shall be 1” SCH40 PVC. All lateral piping shall be SCH40 PVC and/or 100psi PE
pipe. All pipe sizes are 1” on plan. Drip piping is acceptable at 3/4”.
3. Wiring is 18awg multi-strand.
1. The plan is diagrammatic for piping, wiring, and head locations. Adjust all piping and heads when
obvious obstructions or grade changes exist.
4. Sprinkler head spacing and location dictate type of MP100 and MP2000 Rotator nozzle.
6. All electrical and manual valves are to be installed within 12” depth standard size or larger boxes. No
more than four valves allowed per box.
5. A Rainbird ESP3ME controller shall be installed in the designated location (TBD). Power source for
irrigation controller to be supplie by others and coordinated with general contractor.
7. An appropriate backflow assembly and exterior connection point shall be supplied and installed by others within
approved mechanical room (TBD). It is the responsibility of the landscape contractor to coordinate installation
per local codes and ordinaces as well as with architecture and all other trades.
8. Install a Rainbird WR2RFC Rain/Freeze sensor in a location where obvious overhead obstructions are
absent and sensor will not be oversprayed by irrigation system
9. Turf valves to be line-size Rainbird DV100 and Drip valves to be Rainbird XCZLF-100-PRF. All isolation
valves shall be line-sized ( 1” ).
10. Irrigation Contractor shall adjust all sprinklers to provide proper radius and to minimize overspray
onto buildings, sidewalks, roads, etc.
11. All Sprinkler nozzles to be Hunter MP Rotators with Rainbird 1804SAM-P45 spray bodies or equal.
12. Planting beds shall be irrigated with point-source drip irrigation based on individual plant water-requirements.
13. All mixed shrub and tree plantings to be irrigated with dedicated drip tubing. Drip emitters to be adjusted per requirements of each individual plant. See Plant Water Schedule.
14. System designed to fall within opertating pressure of 60 psi. and 15 gpm.
15. ALL SLEEVING TO BE 4” SCH40 PVC. No Exceptions. Sleeving to be supplied and installed by others. It is
the responsibility of the landscape contractor to coordinate installation with General Contractor.
16. All information to be field verified by Landscape Contractor prior to installation.
17. The contractor shall maintain an accurate and current ‘as-built’ on site at all times.
Days Zone GPM Duration
Minutes
Initial
GPD
(2X Runtime)
Estimated
GPD
Total Daily
Initial
Total Daily
Established
1,3,5,7
2,4,6
1
2
3
4
5
6
7D
8D
6
4
4
14
11
11
3
2
30
30
30
30
30
30
15
45
180
120
120
420
330
330
45
90
360
240
240
840
660
660
90
180
3,270 gal.1,635 gal.
-
-
-
-
-
-
-
-
3,270 gal.0 gal.
Proposed Irrigation Schedule System A
1
2
3
4
5
6
7D
8D
6
4
4
14
11
11
3
2
30
30
30
30
30
30
15
45
360
240
240
840
660
660
90
180
Days Zone GPM Duration
Minutes
Initial
GPD
(2X Runtime)
Estimated
GPD
Total Daily
Initial
Total Daily
Established
1,3,5,7
2,4,6
1
2
3
4
5D
6
14
13
11
2
30
30
30
30
15
180
420
390
330
30
360
840
780
660
60
2,700 gal.1,350 gal.
-
-
-
-
-
2,700 gal.0 gal.
Proposed Irrigation Schedule System B
1
2
3
4
5D
6
14
13
11
2
30
30
30
30
15
360
840
780
660
60
1” - 1.5” Caliper Tree irrigate w/ .25gpm bubbler
2” - 2.5” Caliper Tree irrigate w/ .25gpm bubbler
4’ Spruce irrigate with .25 gpm bubbler
6’ - 8’ Spruce irrigate with (2) .25 gpm bubbler
10’ - 12’ Spruce irrigate with (3) .25 gpm bubbler
Trees in Turfgrass
1gal pot irrigate with (1) .5gph emitters
2gal pot irrigate with (1) 1gph emitters
5gal pot irrigate with (2) 1gph emitters
10gal pot irrigate with (2) 2gph emitters
1” - 1.5” Caliper Tree irrigate w/ (3) 2gph emitters
2” - 2.5” Caliper Tree irrigate w/ (4) 2gph emitters
4’ Spruce irrigate with (3) 2gph emitters
6’ - 8’ Spruce irrigate with (4) 2gph emitters
10’ - 12’ Spruce irrigate with (5) 2gph emitters
Trees/Shrubs in Beds
MP2000 - 180 = .77gpm @40psi.
MP2000 - 360 = 1.48gpm @40psi.
MP1000 - 90 = .21gpm @40psi.
MP1000 - 180 = .42gpm @40psi.
MP1000 - 360 = .84gpm @40psi.
MP2000 - 90 = .43gpm @40psi.
MPSS = .44gpm @40psi.
MP3000 - 90 = .86gpm @40psi.
MP3000 - 180 = 1.82gpm @40psi.
MP3000 - 360 = 3.64gpm @40psi.
MPCS = .22gpm @40psi.
MP Rotator Performance Data
Plant Water Schedule
(2) 4” Sleeves
C
C
6A
1
4A
3
2A
8D
4A
214A
411A
5
11A
6
11B
4
13B
3
6B
1
14B
2
3A
7D
2B
5D
OFF
ON
3" MIN.
BRICK (1 OF 4)
(LENGTH AS REQUIRED)
PVC MAINLINE PIPE
RAIN BIRD VB-STDFINISH GRADE/TOP OF MULCH
VALVE BOX WITH COVER:
REMOTE CONTROL VALVE:
PVC SCH 40 ELL
30-INCH LINEAR LENGTH OF WIRE, COILED
ID TAG: RAIN BIRD VID SERIES
WATERPROOF CONNECTION: RAIN BIRD SPLICE-1 (1 OF 2)
HIDDEN) AND SCH 40 ELL
PVC SCH 80 NIPPLE
SCH 80 NIPPLE (2-INCH LENGTH,
PVC SCH 40 TEE OR ELL
3.0-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL
POLYETHYLENE LATERAL PIPE
RAIN BIRD 100-DV-MB
POLYETHYLENE PIPE CLAMP
ELECTRIC REMOTE-CONTROL VALVE2N.T.S.DV SERIES 100-DV-MB
QUICK-COUPLING VALVE:
(LENGTH AS REQUIRED)PVC SCH 80 NIPPLE
PVC MAINLINE PIPE
(LENGTH AS REQUIRED)PVC SCH 80 NIPPLE
3-INCH MINIMUM DEPTH OF
VALVE BOX WITH COVER:
CLAMPS OR EQUIVALENT SUPPORT SYSTEM
RAIN BIRD MODEL 3RC
RAIN BIRD VB-6RND
STAINLESS STEEL GEAR
PVC SCH 40 TEE OR ELL
PVC SCH 40 ELL
2" x 2" REDWOOD STAKE WITH
FINISH GRADE/TOP OF MULCH
3/4-INCH WASHED GRAVEL
PVC SCH 40 STREET ELL
BRICK (1 OF 2)
PVC SCH 40 STREET ELL
NOMINAL QUICK COUPLING VALVE INLET SIZE.FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TONOTE:
4 QUICK COUPLING VALVE
MODEL 3RCN.T.S.
12"18"12"18"
FINISH GRADE
LATERAL
LATERAL
MAIN LINE
BEDDING
LOW VOLTAGE WIRE
LOW VOLTAGE WIRE
SECTIONS
SNAKE ALLLATERAL PIPEIN TRENCH
PIPE, WIRE, TRENCHING5N.T.S.
SWING PIPE, 12-INCH LENGTH:
PVC/POLY LATERAL PIPE
RAIN BIRD MODEL SP-100
BARB ELBOW: RAIN BIRD1/2-INCH MALE NPT x .490 INCH
MODEL SBE-050
PVC SCH 40 TEE OR ELL
MODEL SBE-050
1/2-INCH MALE NPT x .490 INCH BARB ELBOW: RAIN BIRD
FINISH GRADE/TOP OF MULCH
RAIN BIRD 1804POP-UP SPRAY SPRINKLER:-SAM-P45
3 POP-UP SPRAY SPRINKLER
1804 WITH SWING PIPEN.T.S.
WITH RAIN BIRD ROTARY NOZZLE
MP ROTATOR NOZZLE
GALVANIZED TIEDOWN STAKE:
PRESSURECOMPENSATING
EMITTER MODULE
" VINYL DISTRIBUTION
TUBING
DIFFUSER BUG CAP
TREE
XERI-TUBE
ADAPTERFITTING AND RISER
LATERAL PIPE
FLUSH FITTINGTREE PLAN
DIFFUSER BUG CAP:
" TUBING STAKE:
MULCH AS SPECIFIED
WEED CONTROL FABRIC
" VINYL DISTRIBUTION
TUBING
XERI-TUBE
SINGLE-OUTLET EMITTER
TREE SECTION
NOTE:
1.EMITTERS SHOULD BE PLACED INSIDE TREE WELL, HALFWAYBETWEEN THE BASE OF THE TREE AND EDGE OF ITS
CANOPY.
2.RUN XERI-TUBE DISTRIBUTION TUBING NOMORE THAN 250' LENGTH
3.RUN 14" VINYL DISTRIBUTION TUBING NOMORE THAN 5' LENGTH
TREE AND SHRUB DRIP6N.T.S.
14
14
14
MOUNTING WALL
RAIN BIRD ESP-ME3
-INCH PVC SCH 40 CONDUIT
WIRES TO VALVES
STANDARD MODULE FOR4-STATION CONTOLLERS
OPTIONAL MODULES FOR22-STATION CONTROLLERSTANDARD 120 V PLUG
ESP-ME3 MODULAR HYBRID CONTROLLER
INSIDE FRONT COVER
INSIDE CONTROLLER CHASSIS
WIRES TO VALVES
120 VAC, 60 HZ INTERNALTRANSFORMER
1 N.T.S.
34
4” SCH40 Sleeving
MP STRIP
Zone Valve
MP 1000/MP2000
Isolation Valve
Quick Connect
ZONE #
GPMCONTROLLER##
#
1” Mainline w/ multi-strand
3/4” or 1” Drip supply line
IRRIGATION LEGEND
1” Lateral line
MP3000
ControllerC