Loading...
HomeMy WebLinkAbout005 Project NarrativeSolstice Design Build hello@solsticedb.com 801.558.7705 www.solsticedb.com PO Box 712385 SLC, UT 84171 Project Narrative:The Lofts on Beall 5.20.2022 Narrative The proposed project at 1608 W Beall Street is a 0.72 acre development consisting of (6) 2-bedroom dwelling units and (5) 3-bedroom dwelling units in (2) total structures. It is a B-2 zoned property adjacent to R-2 and R-3 zones to the North of Beall Street. Due to the current B-2 zoning, a Conditional Use Permit application has been submitted simultaneously with the Site Plan application. The project design has been revised from the Concept Design and earlier Site Plan Review submittal to comply with BMC Table 38.310.040.C, Note #7. This original proposed design of (10) dwelling units in four separate structures has been revised to (11) dwelling units in two separate structures of (5) and (6) attached units. Each dwelling unit contains either a 1-car or 2-car garage with additional driveway and on-site parking. Excellent pedestrian circulation is provided throughout the site. The project will have on-site underground basins for stormwater runo and on-site snow storage areas are provided in convenient locations. Individual totes will be used for solid waste, stored in the garage. All construction including infrastructure and site development is proposed to occur at once. The property sits within the Bozeman Solvent Site and the existing monitoring wellheads will remain undisturbed by the proposed development. Per discussions with the Montana Department of Environmental Quality, there are no restrictions that would adversely aect the development. The proposed design of the project responds to several unique site characteristics including: 1)The location of the project site is at a transitional boundary between commercial and residential zones and thus a building form, scale and material palette is proposed which blends with the character of the existing neighborhood. Neighboring structures include single-family homes, single-story commercial structures directly to the East and West, nearby apartment buildings, a shopping center to the South, and parks and a school campus within ¼ mile. 2)The proposed design takes advantage of mountain views to the North with upper level living areas and balconies, and takes advantage of a high potential for rooftop photovoltaic with large, unobstructed, South-facing roof planes. Each dwelling unit will be ready for rooftop solar with the option to add rooftop solar marketed to each future homeowner at the time of purchase. The project will be Page 1 of 2 ‘all-electric’ with the potential for rooftop PV to oset all or most of the net energy use for each unit. 3)The irregular site shape and locations of existing monitoring wellheads aect the overall site layout, which includes a landscaped area to the SouthEast corner of the site with an infiltration basin for stormwater runo. Existing wellheads will not be disturbed or impacted with the development. Despite site constraints, a total of 11 rowhouse-style dwelling units are proposed (15/ acre) with adequate on-site parking and open space. The proposed project will oer two-bedroom and three-bedroom, for-sale housing units on a currently undeveloped site in a transitional neighborhood within City limits. Parking for the project exceeds minimum requirements with on-site parking spaces. Parking calculations are provided below: Required parking spaces: 27 Garage spaces: 17 Stacked driveway spaces: 5 Additional on-site parking: 5 On-street spaces: 2 Total Parking Spaces: 29 Sincerely, Solstice Design Build Shay Myers, AIA Principal Architect Page 2 of 2