HomeMy WebLinkAbout094 Elevations TriplexMAIN FLOOR 100' -0" UPPER T.O. PLATE 119' -7" MAIN T.O. PLATE 109' -1 1/8" 123 SECOND FLOOR 110' -5 7/8" 4 7" / 12"2 AT5.12 7" / 12"7" / 12"7" / 12"H H G G B B CC (E)(E) (T) MAIN FLOOR 100' -0" UPPER T.O. PLATE 119' -7" MAIN T.O. PLATE 109' -1 1/8" T.O. FOUNDATION 99' -9 3/4" 2 AT5.1112 3 SECOND FLOOR 110' -5 7/8" 4 12" / 12"2 AT5.12 GG B B H H CC12" / 12"12" / 12"12" / 12"12" / 12"(T)(T) (T)(T) (F) WHEN TAGGED ON BUILDING ELEVATIONS, INDICATES FROSTED GLAZING (T) WHEN TAGGED ON BUILDING ELEVATIONS, INDICATES TEMPERED SAFETY GLAZING REQUIRED (E) WHEN TAGGED ON BUILDING ELEVATIONS, INDICATES EGRESS OPERABILITY (WCOD) WHEN TAGGED ON BUILDING ELEVATIONS, INDICATES 4" WINDOW OPENING CONTROL DEVICE SAFETY GLAZING PROVIDE TEMPERED GLAZING IN ALL IN ALL AREAS SUBJECT TO HUMAN IMPACT AS PRESCRIBED BY THE 2018 IRC. FALL PROTECTION ALL WINDOWS INSTALLED WITH A SILL HT. BELOW 24" AND 6' ABOVE FINISHED GRADE SHALL BE EQUIPPED WITH WINDOW OPENING CONTROL DEVICE (WCOD) THAT DOES NOT OPEN MORE THAT 4" INCHES. EGRESS AREAS EGRESS OPENINGS IN SLEEPING AREAS REQUIRED TO MEET THE IRC 2018 SECTION R310. WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY SHALL HAVE NOT MORE THAN 44" SILL HEIGHT, MEASURED FROM FINISHED FLOOR TO BOTTOM EDGE OF CLEAR OPENING. MINIMUM OPENING AREA -5.7 SF. (R310.1.1) MINIMUM OPENING HEIGHT -24" CLEAR (R310.1.2) MINIMUM OPENING WIDTH -20" CLEAR (R310.1.3) WINDOW NOTES SCALE: DRAWN: PROJECT NO: PO box 1001 Bozeman, MT 59771 DATE: 1/4" = 1'-0" 1/7/2022 10:14:02 AM AT3.12 2001 ElevationsSix Range TriplexPaine Group4270 W Babcock Street, Bozeman MTDRC Site Plan Re-Submittal 2021.01.071/4" = 1'-0"1 EAST ELEVATION 1/4" = 1'-0"2 WEST ELEVATION