HomeMy WebLinkAbout038 E0.0 ELEC LEGEND&GENERAL NOTESAAMMETER, AMPERE, AUTOMATIC, PHASE AACALTERNATING CURRENT, AIR CONDITIONERACEGAC EQUIPMENT GROUNDINGAICAMPERE INTERRUPTING CURRENTAFAMPERE FRAMEAFFABOVE FINISH FLOORAHUAIR HANDLING UNITANNANNUNCIATORASAMPERE SWITCHASSDAIR SAMPLING SMOKE DETECTION SYSTEMATAMPERE TRIPATSAUTOMATIC TRANSFER SWITCHAWGAMERICAN WIRE GAUGEBPHASE BBACBUILDING AUTOMATION CABINETBATTBATTERYYBLDGBUILDINGBKRBREAKERBSTCBARE SOLID TINNED COPPERCCOMMUNICATIONS, CONDUIT, PHASE CCABCABINETCBCIRCUIT BREAKERCCTVCLOSED CIRCUIT TELEVISIONCCVECLOSED CIRCUIT VIDEO EQUIPMENTCHWPCHILLED WATER PUMPCIRCCIRCULATIONCKTCIRCUITCLGCEILINGCMUCONCRETE MASONRY UNITCOCONDUIT ONLYCOLCOLUMNCOMMCOMMUNICATIONSCONCCONCRETECONTRCONTRACTORCPTCONTROL POWER TRANSFORMERCRCONTROL RELAYCSCONTROL SWITCHCSICONSTRUCTION SPECIFICATIONS INSTITUTECTCURRENT TRANSFORMERCTLCONTROLCUCOPPERDDEEP, DEPTHDCDIRECT CURRENTDDCDIRECT DIGITAL CONTROLDETDETAILDIADIAMETERDISCDISCONNECTDNDOWNDPSTDOUBLE POLE SINGLE THROWDRDOORDSDOWN SPOUTDSUDISCONNECTION SWITCH UNITDWGDRAWINGEAEACHEFEXHAUST FANELELEVATIONELECELECTRIC(AL)ELEVELEVATOREMEREMERGENCYEMTELECTRIC METALLIC TUBINGEQUIPEQUIPMENTEWCELECTRIC WATER COOLEREWHELECTRIC WATER/WALL HEATEREXTEXTERIORFAFIRE ALARMFAAFIRE ALARM ANNUNCIATORFACPFIRE ALARM CONTROL PANELFAPFIRE ALARM PANELFCPSFIELD CHARGING POWER SUPPLYFDRFEEDERFDFLOOR DRAINFEFIRE EXTINGUISHERFECFIRE EXTINGUISHER CABINETFFFACTORY FINISH, FINISH FACEFHFULL HEIGHTFICFURNISHED AND INSTALLED BY CONTRACTORFINFINISH(ED)FIXTFIXTUREFLEXFLEXIBLEFLRFLOORFLUORFLUORESCENTFOICFURNISHED BY OWNER INSTALLED BY CONTRACTORFSCSFIRE FIGHTER SMOKE CONTROL STATIONFTFEET/FOOTFUFUSEFUTFUTUREFVNRFULL VOLTAGE NON-REVERSINGGGROUNDGALVGALVANIZEDGENGENERAL, GENERATORGFGROUND FAULTGFCIGROUND FAULT CIRCUIT INTERRUPTERGFIGROUND FAULT INTERRUPTERGNDGROUNDGRCGALVANIZED RIGID CONDUITGRSGALVANIZED RIGID STEELHHIGHHHHAND HOLEHIDHIGH INTENSITY DISCHARGEHOAHAND-OFF-AUTOHORIZHORIZONTALHPHORSE POWERHPFHIGH POWER FACTORHPSHIGH PRESSURE SODIUMHTRHEATERHVACHEATING, VENTILATION AND AIR CONDITIONINGHZHERTZ (CYCLES PER SECOND)ICINTERRUPTING CAPACITYIDINSIDE DIAMETERININCHINSTRINSTRUMENTIZSISOLATED GROUND SYSTEMIZGISOLATED GROUND ZONEJ, J-BOXJUNCTION BOXkAICAMPERE INTERRUPTING CURRENT (THOUSANDS)kcmilTHOUSAND CIRCULAR MILSkVAKILOVOLTAMPERESkWKILOWATTSkWHKILOWATT HOURSLLENGTH, LONGLTLIGHTLTGLIGHTINGLVLLEVELMAXMAXIMUMMCBMAIN CIRCUIT BREAKERMCCMOTOR CONTROL CENTERMCPMOTOR CIRCUIT PROTECTORMECHMECHANICALMFRMANUFACTURERMGMOTOR GENERATORMGBMASTER GROUND BARMHMANHOLE, METAL HALIDEMINMINIMUM, MINUTEMLOMAIN LUGS ONLYMSCMOBILE SWITCHING CENTERMTDMOUNTEDMTGMOUNTINGMTR,MMOTORMTSMANUAL TRANSFER SWITCHN,NEUNEUTRALNECNATIONAL ELECTRICAL CODENCNORMALLY CLOSEDNICNOT IN CONTRACTNLNIGHT LIGHTNONUMBER, NORMALLY OPENNTSNOT TO SCALEODOUTSIDE DIAMETEROPNGOPENINGOSOCCUPANCY SENSORPPOLEPCPHOTOELECTRIC CELLPCDPOWER CONTROL DISTRIBUTIONPCDFPOWER CONTROL DISTRIBUTION FRAMEPCUPOWER CONTROL UNITPDFPROTECTOR DISTRIBUTION FRAMEPDUPOWER DISTRIBUTION UNITPFPOWER FACTORPH,∅PHASEPIRPASSIVE INFRAREDPKGPACKAGEPNLPANEL, PANELBOARDPERPPREPARATIONPTPOTENTIAL TRANSFORMERP/TPAN/TILTP/T/ZPAN/TILT/ZOOMPVCPOLYVINYL CHLORIDEPWRPOWERQTYQUANTITYRRADIUS, RISERRECRECEPTACLEREFREFRIGERATORREGREGISTERREQDREQUIREDREVREVISED, REVISIONRGSRIGID GALVANIZED STEELRMROOMSCHEDSCHEDULESECTSECTIONSFDSMOKE FIRE DAMPERSHLDSHIELDEDSOVSOLENOID OPERATED VALVESPECSPECIFICATIONSPGSINGLE POINT GROUNDSPSTSINGLE POLE SINGLE THROWSQSQUARESTSHUNT TRIPSTBYSTAND BYSTDSTANDARDSBTCSOLID BARE TINNED COPPERSUBSUBSTATIONSWSWITCHSWBDSWITCHBOARDSWGRSWITCHGEARSYSSYSTEMTTIMERTBTERMINAL BLOCKTCTIME CLOCKTELTELEPHONETEMPTEMPORARY, TEMPERATURETTBTELEPHONE TERMINAL BOARDTVSSTRANSIENT VOLTAGE SURGE SUPPRESSIONTYPTYPICALUCUNDER COUNTERUG/CNUNDERGROUND COMMUNICATIONS NETWORKUG/LVUNDERGROUND LOW VOLTAGE CABLEUG/TUNDERGROUND TELEPHONE CABLEUHUNIT HEATERULUNDERWRITERS LABORATORIESVVOLT(S)VFDVARIABLE FREQUENCY DRIVEWWATT(S), WIRE, WIDE, WESTW/WITHW/OWITHOUTWHMWATT HOUR METERWPWATERPROOF, WEATHERPROOFXFMRTRANSFORMERZIMPEDANCEissue dateproject #phasesheetprojectownerrevisiondate100% CONSTRUCTION DOCUMENTS6/20/2022 4:41:14 PM6/15/221E0.06.10.2022ELECTRICAL LEGEND AND GENERAL NOTES21087.00100% CDAURORA TECHNOLOGIESINNOVATION CAMPUS PARTNERSABBREVIATIONS:POWER/PLAN SYMBOLS:LIGHTING SYMBOLS:GENERAL NOTES:SHEET INDEX:ONE-LINE SYMBOLS:COMMUNICATION/SYSTEM SYMBOLS:GROUNDING AND LIGHTNING PROTECTION SYMBOLS:E0.0 ELECTRICAL LEGEND AND GENERAL NOTESE1.1 ELECTRICAL SITE PLANE1.2 ELECTRICAL PHOTOMETRICS PLANE1.3 PARKING AREA PHOTOMETRICS PLANE2.1 POWER LEVEL 1 OVERALL PLANE2.2 POWER LEVEL 2 OVERALL PLANE2.3 MECHANICAL POWER LEVEL 1 OVERALL PLANE2.4 MECHANICAL POWER LEVEL 2 OVERALL PLANE2.5 LIGHTING LEVEL 1 OVERALL PLANE2.6 LIGHTING LEVEL 2 OVERALL PLANE2.7 ELECTRICAL ROOF PLAN WEST LOWERE2.8 ELECTRICAL ROOF PLAN EASTE3.1 POWER FIRST FLOOR PLAN WESTE3.2 POWER FIRST FLOOR PLAN EASTE3.3 POWER SECOND FLOOR PLAN EASTE3.4 MECHANICAL POWER FIRST FLOOR PLAN WESTE3.5 MECHANICAL POWER FIRST FLOOR PLAN EASTE3.6 MECHANICAL POWER SECOND FLOOR PLAN EASTE3.7 LIGHTING FIRST FLOOR PLAN WESTE3.8 LIGHTING FIRST FLOOR PLAN EASTE3.9 LIGHTING SECOND FLOOR PLAN EASTE3.10 LIGHTNING PROTECTION ROOF PLAN WESTE3.11 LIGHTNING PROTECTION ROOF PLAN EASTE3.12 CONDUIT ROUTING PLAN WESTE3.13 CONDUIT ROUTING PLAN EASTE4.1 ELECTRICAL ELEVATIONSE5.1 ELECTRICAL DETAILSE5.2 TYPICAL DETAILSE5.3 TYPICAL DETAILSE5.4 TYPICAL DETAILSE5.5 TYPICAL DETAILSE5.6 TYPICAL DETAILSE5.7 TYPICAL DETAILSE9.1 MECHANICAL EQUIPMENT SCHEDULEE9.2 ELECTRICAL LIGHTING SCHEDULEE9.3 ELECTRICAL PANEL SCHEDULESE9.4 ELECTRICAL PANEL SCHEDULESE9.5 ELECTRICAL PANEL SCHEDULESE10.1 ELECTRICAL ONE LINE DIAGRAME10.2 ELECTRICAL FEEDER CIRCUIT SCHEDULES111. COORDINATION:A. EACH DIVISION SHALL COMPLY WITH THE G001 PROJECT GENERAL NOTES AS IF CONTAINED HEREIN.B. CONTRACTOR SHALL SUBMIT COORDINATION DRAWINGS FOR REVIEW AND APPROVAL PRIOR TO COMMENCEMENT OF WORK. CONTRACTOR IS RESPONSIBLE FOR ASSEMBLY AND COORDINATION OF WORK WITHIN ALL DIVISIONS AND TRADES INTO A SINGLE PACKAGE.2. DO NOT SCALE DRAWINGS:THE CONTRACTORS SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENT. NOTIFY THE AE PROJECT MANAGER IF ANY DISCREPANCIES ARE FOUND PRIOR TO PROCEEDING WITH WORK.3. FIRESTOPPING SHALL BE PROVIDED PER A SHEET REQUIREMENTS.4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE AND DETERMINE THE EXACT EXTENT OF WORK, COORDINATION, DEMOLITION, TEMPORARY CONSTRUCTION, TEMPORARY FACILITIES, UTILITIES, ETC. NECESSARY TO COMPLETE THIS PROJECT AS INDICATED IN THE CONTRACT DOCUMENTS.5. ALL CONDUIT SHALL BE INSTALLED CONCEALED IN FINISHED AREA UNLESS NOTED OTHERWISE.6. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND APPROVED BY STRUCTURAL ENGINEER.7. PAINT EXPOSED CONDUIT TO MATCH EXISTING WITHIN THE SURROUNDING AREA.8. COORDINATE INSTALLATION OF WALL AND FLOOR DEVICES WITH ARCHITECTURAL ELEVATIONS AND FURNITURE PLANS AND/OR SPECIALTY EQUIPMENT SHOP DRAWINGS PRIOR TO ROUGH IN.9. COORDINATE INSTALLATION OF ELECTRICAL DEVICES SERVING MECHANICAL EQUIPMENT WITH MECHANICAL WORK PRIOR TO ROUGH IN.10. DISCONNECT LOCATIONS ARE SHOWN DIAGRAMMATICALLY ONLY AND SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS WITHIN LINE OF SITE TO EQUIPMENT THEY SERVE. MOUNT AT 6'-3" MAX. HEIGHT TO TOP OF ENCLOSURE.11. ALL FLOOR MOUNTED EQUIPMENT SHALL BE MOUNTED ON A 4" HOUSE KEEPING PAD UNLESS NOTED OTHERWISE.12. PROVIDE FUSES PER EQUIPMENT MANUFACTURER'S REQUIREMENTS.13. SEE MECHANICAL EQUIPMENT SCHEDULE FOR CIRCUIT AND OVERCURRENT SIZES.14. PROVIDE A GREEN INSULATED GROUNDING CONDUCTOR FOR ALL CIRCUITS.15. PROVIDE EQUIPMENT PROTECTION ABOVE ALL NETWORK EQUIPMENT (INCLUDING BUT NOT LIMITED TO CABLING, BUS, CABLE TRAY, EQUIPMENT BAYS, RECTIFIERS, BATTERIES, INVERTERS, DISTRIBUTION PANELS, ETC.) WHEN WORKING ABOVE EQUIPMENT. ALL PROTECTION SHALL BE COORDINATED WITH THE OWNER TO ENSURE THAT THE PROTECTION WILL NOT BLOCK ACCESS TO EQUIPMENT OR CAUSE OVERHEATING. PROVIDE TEMPORARY COOLING AS REQUIRED.16. PROVIDE ALL POWER CONNECTIONS FOR FIRE SMOKE DAMPERS INCLUDING CONNECTIONS BETWEEN FSD CONTROL RELAYS AND FSD'S.17. PROVIDE 2-HOLE LUGS CAPABLE OF ACCEPTING MULTIPLE CRIMPS FOR ALL POWER AND GROUNDING CONNECTIONS TO A BUS OR WHERE FEASIBLE. USE MANUFACTURER'S COMPRESSION TOOL WITH PROPER DIE FOR EACH CONNECTOR. MANUFACTURER'S EMBOSSED CODING SYSTEM IS REQUIRED. A UNIVERSAL OR DIE-LESS TYPE CRIMPING TOOL SHALL NOT BE USED. PROVIDE LUGS WITH INSPECTION HOLE FOR ALL INTERIOR INSTALLATIONS. PROVIDE CLOSED LUGS (NO INSPECTION HOLE) FOR EXTERIOR OR UNDERGROUND CONNECTIONS.18. ALL RECESSED PANELS MOUNTED IN FIRE RATED WALLS SHALL BE OF FIRE RATED CONSTRUCTION TO MATCH RATING OF WALL. (i.e. TRAP PRIMERS, F.E. CABINETS, etc.)