HomeMy WebLinkAbout036 A2.5 ROOF DETAILS6"1"3"3"MIN.1"MIN.1/2"ROOF ASSEMBLY. SLOPE & ELEVATION MAY VARYBUILT-UP FLASHINGSEALANTSEALANT1" STRUCTURAL THERMAL SPACER, BUSHINGS, & WASHERS. BASIS OF DESIGN: FABREEEKA "TIM" TOP-CHORD OF ROOF STRUCTURAL ASSEMBLY, REF. STR'L. ROOF DECK, REF. STR'LT/FR ROOFREF STR'L8" MIN6"ROOF ASSEMBLY. SLOPE & ELEVATION MAY VARYROOF DECK, REF. STR'LT/FR ROOFREF STR'L8" MIN3' - 6"9' - 0"EQEQEQFLASHING / BOOT AROUND BASE OF PENETRATION, PER ROOF MFGRBASE PLATE & CONNECTION, PER STR'LBEAM, PER STR'LHSS POST, PER STR'LHSS RAIL(S), PER STR'LMP-3, METAL PANELPRE-FINISHED METAL COPING, TO MATCH MP-3PANEL(S)A2.123LAP IN POURABLE SEALER POCKET TO BE POP RIVETEDTO PREVENT MOVEMENT THAT COULD AFFECT OVERLAY SEALREF: SMACNA FOR POURABLE SEALER POCKET FABRICATION DIRECTIONS.SIZE TO PROVIDE 1" OF CLEARANCE BETWEEN PENETRATIONS AND SIDE POCKETS.JOB SITE CONDITIONS MAY REQUIRE THAT THE POCKETS BE ASSEMBLED ON SITE.POURABLE SEALERBY ROOFING MANUFACTURERMOUND TO SHED WATERCOATED METALBY ROOFING MFRMINIMUM 1 1/2" WELDMEMBRANE ROOFING ASSEMBLYEDGE SEALANTBY ROOFING MANUFACTURERAPPLIED TO SPLICE WASHED EDGE OFREINFORCED FLASHING -SEAL EDGESFIELD FABRICATE CORNER OFUNSUPPORTED TPO FLASHINGREINFORCED MEMBRANE FLASHING WELDED TO POURABLE SEALER POCKETFLANGE TIGHT TO ANGLE CHANGEREF: MEP SHEETS FOR LOCATIONSROOF MASTIC (TYP.) CONT.(3) VANDAL PROOF SETSCREWS (TYP.)PERMASEALSTEEL REINFORCINGPROVIDE STORMTITE LEAD FLASHING NO. S1100-4 W/6" SKIRT (PROVIDE LEADFLASHING ON ALL THRUROOF PENETRATIONS)CONDUIT OR PIPE ASOCCURS, 8" SKIRT7"AS REQUIRED5"2 1/2"MEMBRANE ATTACHMENT AT 12" OUT FROM PENETRATION AND 12" O.C.REQUIRED FOR MECHANICALLY ATTACHED ROOF SYSTEMS.THIS CAN BE ACCOMPLISHED WITH SEAM PLATES AND FASTENERSOVERLAID WITH EITHER COVER TAPE, A TARGET PATCH OF THEFIELD MEMBRANE FOR THE BOOT FLANGE TO BE WELDED TO, ORWITHIN 6" OF REINFORCED FLASHING.WHEN INSTALLATION OF THE PIPE BOOT WOULD OVERLAP A FIELDSEAM, INSTALL A MINIMUM OF 24" X 24" TARGET PATCH, CENTERED ONTHE PENETRATION BEFORE CENTERED ON THE PENETRATION BEFOREINSTALLING THE PIPE BOOT.AS AN ALTERNATIVE; MEMBRANE ATTACHMENT MAY ALSO BEINSTALLED CLOSE TO PENETRATION AND FLASHED WITH PIPE BOOTAS SHOWN HERE.REF: MEP SHEETS FOR LOCATIONSPRE-MOLDED PIPE BOOT HOT AIR WELDSTANDARD BOT FLANGE TO DECKMEMBRANE OR APPLY THE PEEL ANDSTICK BOOT FLANGE TO THE PRIMEDMEMBRANE WITH A 2" SILICONE ROLLEREXISTING ROOF ASSEMBLYRIGID INSULATIONSUBSTRATE6"x6" MEMBRANE WELDED TO BACK OF PROTECTION PAD & TO ROOFING MEMBRANE IN FIELD (TYP)2'x4'x1/4"PROTECTIONPAD2' - 0" TYP. PAD4' - 0"6"6"PLAN VIEWHEAT WELD ALL 4 SIDES OF THEWALKWAY TO ROOF MEMBRANEAS PER MFR SPECS.COMPATIBLE w/SPECIFIED ROOF MATERIAL.NOTES:-PROVIDE WALKWAY FROM ROOF ACCESS TO ALL SERVICEABLE MECHANICAL EQUIPMENT. -WALKWAY SECTIONS SPACED TO ALLOW FOR DRAINAGE BETWEEN SECTIONS: 1" MIN. TO 3" MAX.2' - 6"2" MIN11/2"HOT PIPEBASE WRAP TO EXTEND MINIMUM 1" UP VERTICALSURFACE OF PIPE AND 2" MINIMUM ONTO FIELD MEMBRANEWITH A SOLID WELD TO THE DECK MEMBRANE.UPPER WRAP TO EXTEND 1-1/2" ONTO BASE WRAP AND8" MINIMUM UP PIPE AND SEALED INTO A BEAD OFWATER STOP WITH A STAINLESS STEEL COMPRESSION BAND.METAL HOODWATER STOPROOF ASSEMBLY() PATCHREF: MEP SHEETS FOR LOCATIONSNON-LIFTABLEEPDM WASHERED FASTENER AS REQUIREDGALVANIZED ANNULAR RING SHANK NAILS (3" O.C.)ALUMINUM TERMINATION / RESTRAINT BAR, FASTENED WITH APPROVED FASTENERS (8" O.C.)INSULATED CURB CONSTRUCTION, REFER TO MECHANICAL DRAWINGSINSULATION ATTACHED PER SPECIFICATION REQUIREMENTSMEMBRANEHOT AIR WELDROOF TOP UNIT OR SKYLIGHT8" MIN.MEMBRANE FLASHING ADHERED IN FTR #201 OR #190e ADHESIVEPREMOLDED CORNERFLASHING (FULLY ADHERED)METAL COUNTERFLASHING, FASTEN W WASHERED FASTENERS (12" O.C.)MECHANICAL UNITSEALANT BEHIND TOP OF FLASHINGSTEEL CHANNEL AT PERIMETER OF OPENING30"x36" ROOF SCUTTLE W/ FACTORY FINISH. ATTACH 3/4" EXT. PLYWOOD TO SIDES W/ F.H. WD. SCREWS INSIDE TO OUTSIDESPRING LATCH W/ INSIDE HANDLE,W/ HASP & PADLOCK.EXTEND LADDER TO 2"FROM TOP OF ROOF HATCH.LADDER UP SAFETY POST1/2" PLYWD. BEHIND LADDERCANT STRIPLADDER RUNGS -SEE LADDER DETAIL NOTESSTEEL LADDERCOUNTERFLASHINGROOFASSEMBLYSAFETY POST TO EXTEND 30" MIN.ABOVE OPENING7" MIN8"1' - 0"30" N.T.S.LADDER UP SAFETY POST TO EXTEND 30" MIN. ABOVE OPENINGPRIME & PAINTB. PLANA. ELEVATIONL6 x 3 x 1/4 x 3"STEEL ANGLE WALL BRACKETPRIME & PAINTLADDER RUNGS3/4" DIA. STL. BARSSLIP-RESISTANT, PRIME & PAINTLADDER SIDEWALLS3/8" x 2 1/2" STEEL PLATEPRIME & PAINTPROVIDE 2x8 BLOCKINGAT WALL BRACKETLOCATIONS INFRAME WALLSF.F.L.TOESPACEVARIES1' - 0"1' - 0"5'-0" MAX. O.C., TYP.1' - 6"TOTAL HEIGHT7" MIN1' - 6" MIN4" RIGID INSULATION MINIMUM AT DRAINSLOPE 1/2":12" AT PERIMETER OF DRAIN; EXTEND TO MEET TYPICAL FIELD ROOF SLOPE, SEE ROOF PLANINSERT ROOFING MEMBRANE FLASHING INTO ROOF DRAIN CLAMPING RINGEXTEND ROOFING MEMBRANE 1" BEYOND INSIDE OF CLAMPING RINGFIELD TAPER RIGID INSULATION TO PROVIDE SMOOTH TRANSITION AS REQUIREDHOT AIR WELDFASTENERS AND STRESS PLATES 12" O.C. AROUND SUMP AREADRAIN ASSEMBLY, SEE PLUMBING DRAWINGSNOTE: 1. USE 1/2" : 12" TAPERED ROOF INSULATION TO CREATE DEPRESSED AREA AROUND DRAINS. 2. ALL BOLTS OR CLAMPS MUST BE IN PLACE TO PROVIDE CONSTANT COMPRESSION ON WATER CUT-OFF MASTIC.3. HOLE IN MEMBRANE MUST EXCEED SIZE OF DRAIN PIPE.4. DRAIN PERIMETER TO HAVE TWICE THE SLOPE AS FIELD ROOF SLOPE.5. CUT OF MEMBRANE TO EXTEND 1" MINIMUM FROM ATTACHMENT POINTS OF CLAMPING RING.SEAL PERIMETERWATER CUT-OFF MASTICSEE TYPICAL ROOFING ASSEMBLYCLAMPING PLATE, SEE PLUMBING DRAWINGSSEE SECTIONS6" MTL. STUD WALL1/2" DENS SHEILD ON BOTH SIDES OF WALLFULLY ADHERED ROOF MEMBRANEHEAT WELDED LAPCONTINUOUS BEAD OF SEALANTissue dateproject #phasesheetprojectownerrevisiondate100% CONSTRUCTION DOCUMENTS 6/20/2022 2:58:46 PMA2.1206.10.2022ROOF DETAILS21087.00100% CDAURORA TECHNOLOGIESINNOVATION CAMPUS PARTNERS1 1/2" = 1'-0"3ROOF STAND-OFF DETAIL3/4" = 1'-0"8ROOF SCREEN SECTION -T.I. PACKAGE1" = 1'-0"1POURABLE SEALER POCKET3" = 1'-0"2PIPE PENETRATION DETAIL3/4" = 1'-0"5PRE-FAB PIPE BOOT1/2" = 1'-0"6ROOF WALK PAD DETAIL1" = 1'-0"7WALKWAY PAD1" = 1'-0"9TYP. HOT PIPE WRAP6" = 1'-0"10ROOF CURB DETAIL1 1/2" = 1'-0"13ROOF HATCH DETAIL3/4" = 1'-0"16INT. STEEL LADDER1/8" = 1'-0"17ROOF DRAIN ASSEMBLY DETAIL1 1/2" = 1'-0"18ROOF WALL