HomeMy WebLinkAbout21400 Staff Report Staff Report
The Ridge Lot 7A Site Plan
Application No. 21400
July 5, 2022
Page 1 of 13
Application No. 21400 Type Site Plan
Project Name The Ridge Lot 7A
Summary A site plan application to construct a 6,000 square foot, one story building shell for
professional offices within The Ridge PUD pad site lot 7A. The development includes
parking, sidewalks, landscaping, and other associated site improvements.
Zoning R-O Growth Policy Urban Neighborhood Parcel Size 0.2637 Acres
Overlay District(s) None
Street Address 4351 Fallon Street
Legal Description Ridge Athletic Club Subdivision, S10, T02 S, R05 E, Lot 7A, Plat J-465-A, City of Bozeman,
Gallatin County, Montana.
Owner DA Lane Company, 2320 W. Main St., Suite 6, Bozeman, MT 59718
Applicant Same as Owner
Representative 45 Architecture, 1216 W. Lincoln St, Suite D, Bozeman, MT 59715
Staff Planner Danielle Garber Engineer Karl Johnson
Noticing Public Comment Period Site Posted Adjacent Owners
Mailed
Newspaper Legal Ad
5/11/22 – 5/26/22
5/11/22 5/11/22 N/A
Advisory Boards Board Date Recommendation
Development Review
Committee
5/9/22 The application is adequate, conforms to
standards, and is sufficient for approval with
conditions and code provisions
Community Development
Board – Design Review
NA NA
Recommendation The application is adequate, conforms to standards, and is sufficient for approval with conditions and
code provisions as noted below.
Decision Authority Director of Community Development Due 7/5/22
Full application: https://weblink.bozeman.net/WebLink/Browse.aspx?startid=258198&cr=1
Staff Report
The Ridge Lot 7A Site Plan
Application No. 21400
July 5, 2022
Page 2 of 13
FINDINGS OF FACT AND APPEAL PROVISIONS CERTIFICATE
A) PURSUANT to Chapter 38, Article 2, Bozeman Municipal Code (BMC), and other applicable sections of Ch.38, BMC, public
notice was given, opportunity to submit comment was provided to affected parties, and a review of the Site Plan described in
this report was conducted. The applicant proposed to the City a Site Plan (SP) to construct a 6,000 square foot, one story
building shell for professional offices within The Ridge PUD pad site lot 7A. The development includes parking, sidewalks,
landscaping, and other associated site improvements. The purposes of the Site Plan review were to consider all relevant
evidence relating to public health, safety, welfare, and the other purposes of Ch. 38, BMC; to evaluate the proposal against the
criteria of Sec. 38.230.100 BMC, and the standards of Ch. 38, BMC; and to determine whether the application should be
approved, conditionally approved, or denied.
B) It appeared to the Director that all parties and the public wishing to examine the proposed Site Plan and offer comment were
provided the opportunity to do so. After receiving the recommendation of the relevant advisory bodies established by Ch. 38,
Art. 210, BMC, and considering all matters of record presented with the application and during the public comment period
defined by Ch. 38, BMC, the Director has found that the proposed Site Plan would comply with the requirements of the BMC if
certain conditions were imposed. Therefore, being fully advised of all matters having come before them regarding this
application, the Director makes the following decision.
C) The Site Plan has been found to meet the criteria of Ch. 38, BMC, and is therefore approved, subject to the conditions listed
in this report and the correction of any elements not in conformance with the standards of the Title. The evidence contained in
the submittal materials, advisory body review, public testimony, and this report, justifies the conditions imposed on this
development to ensure that the Site Plan complies with all applicable regulations, and all applicable criteria of Ch. 38, BMC.
On this ______ day of 2022, Anna Bentley, Interim Director of Community Development, approved with
conditions this Site Plan for and on behalf of the City of Bozeman as authorized by Sec. 38.200.010, BMC.
D) This Director of Community Development’s project decision may be appealed by filing a documented appeal with and paying
an appeal fee to the Clerk of the Commission for the City of Bozeman within 10 working days after the date of the final decision
as evidenced by the Director’s signature, following the procedures of Sec. 38.250.030, BMC.
DIRECTOR OF COMMUNITY DEVELOPMENT
Staff Report
The Ridge Lot 7A Site Plan
Application No. 21400
July 5, 2022
Page 3 of 13
CONDITIONS OF APPROVAL
Please note that these conditions are in addition to any required code provisions identified in this report. Additional conditions
of approval and code corrections may be identified during staff review and will be included with the final report provided to the
Director of Community Development.
1. The applicant is advised that unmet code provisions, or code provisions that are not specifically listed as conditions
of approval, does not, in any way, create a waiver or other relaxation of the lawful requirements of the Bozeman
Municipal Code or state law.
2. Cash-in-lieu of water rights (CILWR) must be paid prior to final site plan approval.
3. The applicant must provide and file with the County Clerk and Recorder’s office the executed Waivers of Right to
Protest Creation of Special Improvement Districts (SIDs) on the city standard record form prior to final site plan
approval.
4. Parking lot landscaping surrounding lot 7A within the approved Ridge PUD development plan must be completed,
or a written timeline for completion, in the form of a financial or non-financial security, must be provided prior to
occupancy of the building.
Staff Report
The Ridge Lot 7A Site Plan
Application No. 21400
July 5, 2022
Page 4 of 13
Figure 1: Current Zoning Map
Staff Report
The Ridge Lot 7A Site Plan
Application No. 21400
July 5, 2022
Page 5 of 13
Figure 2: Civil Site & Utility Plan
Staff Report
The Ridge Lot 7A Site Plan
Application No. 21400
July 5, 2022
Page 6 of 13
Figure 3: Landscaping Plan
Staff Report
The Ridge Lot 7A Site Plan
Application No. 21400
July 5, 2022
Page 7 of 13
Figure 4: Elevation
Staff Report
The Ridge Lot 7A Site Plan
Application No. 21400
July 5, 2022
Page 8 of 13
ANALYSIS AND FINDINGS
Analysis and resulting recommendations based on the entirety of the application materials, municipal codes, standards,
plans, public comment, and all other materials available during the review period. Collectively this information is the record
of the review. The analysis in this report is a summary of the completed review.
Plan Review, Section 38.230.100, BMC
In considering applications for plan approval under this title, the Director of Community Development shall consider the
following:
1. Conformance with Article 1 - Consistency with the City’s adopted Growth
Policy 38.100.040.D
Meets Code?
Growth Policy
Land Use
Urban Neighborhood Yes
Zoning R-O, Residential Office Yes
Comments: The project conforms to the requirements of the R-O zoning district, and the approved Ridge Athletic Club Final
PUD, application 17562. R-O is an implementing district of the 2020 Community Plan designation of Urban Neighborhood.
Per BMC 38.310.030, the primary use of a lot, as measured by building area, permitted in the R-O district is determined
by the underlying growth policy land use designation. Where the district lies over a residential growth policy designation the
primary use shall be non-office uses; where the district lies over a non-residential designation the primary use shall be office
and other non-residential uses. Primary use shall be measured by percentage of building floor area. The land use description
for the Urban Neighborhood category is primarily residential homes of all scales at urban density, which would require this lot
to be developed primarily, by more than 50% floor area, as residential. However, this lot is within the Ridge PUD which
augments the zoning requirements and lists offices as a principal permitted use. This application complies with the
development guidelines required with The Ridge Athletic Club development guidelines where required and the R-O zoning
district.
2. Conformance with Article 1 - All other applicable laws, ordinances, and
regulations (38.100.080)
Condominium ownership No
Comments: Additional steps will be required including but not limited to review of final site plan approval and
building permits. The Building Division of the Department of Community Development will review the
requirements of the International Building Code for compliance at the time of building permit application.
3. Conformance with Article 2, including the cessation of any current violations
(38.200.160)
Meets Code?
Current Violations None Yes
Comments: There are no current violations on the property.
4. Conformance with Article 2 - Submittal material (38.220) requirements and
plan review for applicable permit types (38.230)
Meets Code?
Site Plan Yes
Submittal requirements 38.220.100 Yes
Phasing of development
38.230.020.B
No. of phases: 1 Yes
Comments: This project is a single pad site within already developed parking and circulation. Condition of
approval 4 requires The Ridge PUD ownership to provide parking lot landscaping prior to occupancy
where outside of Lot 7A.
Any additional use permit (Conditional Use Permit) 38.230.120 or (Special use
Permit) 38.230.120
NA
Staff Report
The Ridge Lot 7A Site Plan
Application No. 21400
July 5, 2022
Page 9 of 13
Comments: No conditional or special uses are proposed.
5. Conformance with Article 3 - Zoning Provisions (38.300) Meets Code?
Permitted uses 38.310 Offices Yes
Form and intensity standards 38.320
Zoning: B-2M Setbacks
(feet)
Structures Parking / Loading Yes
Front Block
Frontage &
PUD 15-feet
Block Frontage &
PUD 15-feet
Rear Zoning – 20,
PUD 5-feet
NA
Side PUD 5-feet NA
Alley NA NA
Comments: Offices are a primary use within the R-O District and The Ridge Athletic Club PUD. The
proposed project is meeting setback requirements for the B-2M district. This application responds to the
Mixed-Landscaped block frontage designations for both Ravalli Street, and Fallon Street, and is meeting
the front setbacks for both these block frontages along the south and west of the project with the 15-foot
required front setback with the PUD. The application is also meeting the required PUD setbacks of 5-feet
for the rear and sides which front onto an existing parking area.
Lot
coverage
52% Allowed 60% (PUD) Yes
Building
height
20’ 10” Allowed 27-34’ (PUD) Yes
Comments: Lot coverage and building height form and intensity standards are met with the proposed design.
Applicable zone specific or overlay standards 38.330-40 NA
Comments: The project is not within an overlay district, or zoning district with specific standards
General land use standards and requirements 38.350 Yes
Comments: Setback encroachments are meeting code standards at the front and sides.
Applicable supplemental use criteria 38.360 NA
Supplemental
uses/type
None NA
Comments: No uses with supplemental use criteria are proposed.
Wireless facilities 38.370 NA
Affordable Housing 38.380.010 NA
Affordable housing plan NA
Comments: No wireless facilities are proposed. No affordable housing requirements are triggered with
the proposed uses.
6a. Conformance with Article 4 - Community Design Provisions: Transportation
Facilities and Access (38.400)
Meets Code?
Streets 38.400.010 NA
Street and road dedication 38.400.020 NA
Access easements NA
Level of Service
38.400.060
Yes Transportation grid adequate to serve
site
Yes
Comments: A traffic study waiver was provided to the applicant by the Engineering Division based on the
size and proposed intensity of the project, and provided peak trip estimates. Level of service standards
for arterial and collector streets serving the site was also evaluated by engineering. A Waiver of Right to
Staff Report
The Ridge Lot 7A Site Plan
Application No. 21400
July 5, 2022
Page 10 of 13
Protest Creation of Special Improvement Districts (SID’s) for future transportation improvements is
required ensuring participation in funding of future infrastructure improvements that may be required to
offset impacts created by development of the property.
Sidewalks 38.400.080 Yes
Comments: Sidewalks both within and adjacent to the site along all street frontages already exist or are
proposed to be provided.
Drive access 38.400.090 Access to site: 2 Yes
Fire lanes, curbs, signage and striping Yes
Comments: A drive access from Fallon Street is already constructed adjacent to lot 7A. This access allow
circulation to lot 7A and to the larger Ridge PUD site. All circulation and parking is provided adjacent to
the rear and side setbacks and is already constructed.
Street vision triangle 38.400.100 Yes
Transportation pathways 38.400.110 NA
Pedestrian access easements for shared use pathways and similar transportation
facilities
NA
Public transportation 38.400.120 Yes
Comments: No new transportation pathways are proposed with this application. Vehicular access is
already constructed. Pedestrian connections the front and rear of the building from the public sidewalk
constructed along Fallon are proposed. An existing Streamline Bus stop exists approximately 975 feet to
the east along the public sidewalk at the Corner of Ferguson Avenue and Fallon Street.
6b. Conformance with Article 4 – Community Design Provisions: Community
Design and Elements (38.410)
Meets Code?
Neighborhood centers 38.410.020 NA
Comments: This project does not trigger neighborhood center requirements.
Lot and block standards 38.410.030-040 NA
Midblock crossing: rights of way for pedestrians alternative block delineation NA
Comments: This project does not trigger lot and block standards.
If the development is adjacent to an existing or approved public park or public open
space area, have provisions been made in the plan to avoid interfering with public
access to and use of that area
NA
Provisions for utilities including efficient public services and utilities 38.410.050-060 Yes
Easements (City and public utility rights-of-way etc.) Yes
Water, sewer, and stormwater Yes
Other utilities (electric, natural gas, communications) Yes
CIL of water Yes
Comments: Requirements were reviewed by engineering. CIL of water rights is required to be paid prior to
site plan approval. Public utility easements along the Fallon and Ravalli frontages have already been
established.
Municipal infrastructure requirements 38.410.070 Yes
Comments: Municipal water, sanitary sewer, and storm sewer systems proposed with this project have
been reviewed by engineering.
Grading & drainage 38.410.080 Yes
Location, design and capacity of stormwater facilities Yes
Stormwater maintenance plan Yes
Landscaping: native species, curvilinear, 75% live vegetation 38.410.080.H NA
Comments: No surface ponds are proposed. Grading and drainage has been reviewed by engineering and
found to be adequate.
Staff Report
The Ridge Lot 7A Site Plan
Application No. 21400
July 5, 2022
Page 11 of 13
Watercourse setback 38.410.100 NA
Watercourse setback planting plan 38.410.100.2.f NA
6c. Conformance with Article 4 – Community Design Provisions: Park and
Recreation Requirements (38.420)
Meets Code?
Parkland requirements 38.420.020.A NA NA
Cash donation in lieu (CIL) 38.420.030 NA
Improvements in-lieu NA
Comments: NA
Park Frontage 38.420.060 NA
Park development 38.420.080 NA
Recreation pathways 38.420.110 NA
Park/Recreational area design NA
Comments: No parks or required parkland are proposed or required with this application.
7a. Conformance with Article 5 – Project Design: Block Frontage Standards
(38.510)
Meets Code?
Block frontage classification Mixed-Landscaped Yes
Departure criteria None requested NA
Comments: The block frontage designations for both Fallon Street and Ravalli Street are Mixed-
Landscaped. The application is meeting building placement with the required PUD setback of 15-feet, and
façade transparency with 34% transparency along Ravalli, and 32% transparency along Fallon. A building
entrance visible and directly accessible from Fallon is proposed. The application is also meeting weather
protection, parking location, landscaping, and sidewalk width requirements.
7b. Conformance with Article 5 – Project Design: Site Planning and Design
Elements (38.520)
Meets Code?
Design and arrangement of the elements of the plan (e.g., buildings, circulation, open
space and landscaping, etc.) so that activities are integrated with the organizational
scheme of the community, neighborhood, and other approved development and produce
an efficient, functionally organized and cohesive development
Yes
Relationship to adjacent properties 38.520.030 NA
Non-motorized circulation and design systems to enhance convenience and safety
across parking lots and streets, including, but not limited to paving patterns, pathway
design, landscaping and lighting 38.420.040
Yes
Comments: Pedestrian paths through the site and to the service areas meet the standards in this section
for location, connections, and widths.
Design of vehicular circulation systems to assure that vehicles can move safely and
easily both within the site and between properties and activities within the general
community 38.420.050
Yes
Internal roadway design 38.520.050.D NA
Comments: NA
On-site open space 38.520.060 NA
Total required NA NA
Total provided NA NA
Comments: Commercial open space is not triggered by this application. Open space is provided within
the Ridge PUD development.
Location and design of service areas and mechanical equipment 38.520.070 Yes
Staff Report
The Ridge Lot 7A Site Plan
Application No. 21400
July 5, 2022
Page 12 of 13
7d. Conformance with Article 5 – Parking (38.540) Meets Code?
Parking requirements 38.540.050 Yes Yes
Parking requirements residential 38.540.050.A.1 0
Reductions residential 38.540.050.A.1.b NA
Parking requirements nonresidential
38.540.050.A.2
20
Reductions nonresidential 38.540.050.A.2.c 4
Provided off-street 16
Provided on-street 4
Bicycle parking 38.540.050.A.4 2
Comments: Parking has already been constructed as a part of The Ridge PUD with 20 parking stalls
provided within the PUD lots and allocated to this lot within the PUD design guidelines. One parking
space was removed by the expansion of the public sidewalk connection at the northeast corner of the lot
to meet current engineering standards for sidewalk width. This space is accommodated by the 20%
parking reduction allowable for R-O zoned lots. Bike parking is to be provided on a concrete pad at the
northwest corner of the building adjacent to the public sidewalk. The bicycle parking will meet the rack
style and dimensions required within this section.
Loading and uploading area requirements 38.540.080 NA
First berth – minimum 70 feet length, 12 feet in width, 14 feet in height NA
Additional berth – minimum 45 feet length NA
Comments: NA
7e. Conformance with Article 5 – Landscaping (38.550) Meets Code?
Mandatory landscaping requirements 38.550.050 Yes
Drought tolerant species 75% required Yes
Parking lot landscaping Yes
Additional screening NA
Street frontage Yes
Street median island NA
Acceptable landscape materials Yes
Protection of landscape areas Yes
Irrigation: plan, water source, system type Yes
Residential adjacency NA
Comments: The provided landscaping plan conforms to standards.
Landscaping of public lands 38.550.070 Yes
Comments: Street trees will be provided along all frontages.
7f. Conformance with Article 5 – Signs (38.560) Meets Code?
Comments: Utility meters and the AC unit are proposed to be screened by a cedar screening fence on
the northwest corner of the building.
7c. Conformance with Article 5 – Project Design: Building Design (38.530) Meets Code?
Compatibility with, and sensitivity to, the immediate environment of the site and the
adjacent neighborhoods and other approved development 38.530.030
Yes
Building massing and articulation 38.530.040 Yes
Building details, materials, and blank wall treatments 38.530.050-070 Yes
Comments: Massing for the single story building is meeting the PUD requirements of at least two primary
materials being used. The application meets the zoning articulation requirements with the use of
windows, structural expression at the building corners, and change in building material.
Staff Report
The Ridge Lot 7A Site Plan
Application No. 21400
July 5, 2022
Page 13 of 13
Allowed SF/building 38.560.060 NA NA
Proposed SF/building NA NA
Comments: No signage is proposed with this application. A separate sign permit is required prior to the
installation of any commercial signs.
7g. Conformance with Article 5 – Lighting (38.560) Meets Code?
Site lighting (supports, cutoff, footcandles, temperature) 38.570.040 Yes
Building-mounted lighting (supports, cutoff, footcandles, temperature) 38.570.040.B Yes
Comments: The application proposes recessed soffit lights at the building entrances. The lighting meets
the required cutoff and intensity requirements.
8. Conformance with Article 6 – Natural Resource Protection Meets Code?
Floodplain regulations 38.600 NA
Wetland regulations 38.610 NA
Comments: NA
9. Relevant Comment from Affected Parties (38.220) Meets Code?
Public Comment Yes
Comments: A public notice period was conducted meeting the requirements of this section and detailed on
page 1 of this report. No public comment has been received as of the writing of this report.
10. Division of Land Pertaining to Subdivisions (38.240-Part 4) Meets Code?
Subdivision exemptions NA
Required easements NA
Comments: No new easements or lot line adjustments are triggered with this application.