HomeMy WebLinkAbout009 G1.2GENERALNOTESPROJECT DESCRIPTION1. DESIGN AND CONSTRUCTION OF A SINGLE STORY GYMNASIUM, PRACTICE FACILITY. WOOD FRAME STRUCTURE WITH WOOD TRUSSESAND CONCRETE FOUNDATION.APPLICABLE CODES2012 INTERNATIONAL ENERGY CONSERVATION CODE2012 INTERNATIONAL BUILDING CODE2012 INTERNATIONAL FUEL GAS CODE2014 NATIONAL ELECTRICAL CODE2012 UNIFORM PLUMBING CODE2012 INTERNATIONAL MECHANICAL CODEANSI A 117.1 - 2003PROJECT INFO & CODE ANALYSIS:ZONING SUMMARYLEGEND:JURISDICTION: CITY OF BOZEMAN ZONING: PUBLIC LANDS AND INSTITUTIONS DISTRICT*ALLOWABLE BLDG. HEIGHT: 65 FEET BUILDING LOT AREA: 64.731 ACRES LEGAL LOT AREA ALLOWED (CODE REFERENCE):FULL COVERAGE OF BLOCK EXCEPT FOR YARD SETBACKSYARD SETBACKS (CODE REFERENCE):FRONT YARD: 15 FT.SIDE YARD: 10 FT.BACK YARD: 10 FT.1 HR FIRE RATED WALL / ASSEMBLY2 HR FIRE RATED WALL / ASSEMBLYFIRE PROTECTIONUSE AND OCCUPANCY:BUILDING HEIGHT AND AREA:TYPE OF CONSTRUCTION:OCCUPANCY GROUPS:A-3OCCUPANCY LOADS (TABLE 1004.1.2)MAIN ASSEMBLY AREA UNCONCENTRATED- SF/15 559 (8,395 SF)ALLOWABLE HEIGHTS / AREAS TABLE 503TYPE VB CONSTRUCTIONGROUP B: 9,000/FLOOR, 2 STORIES (3 STORIES FOR SPRINK.)ALLOWABLE AREA: 9,000/FLR + 18,000/FLR (INCREASE AREA FOR SPRINKLERS) + 14,580/FLR (FRONTAGE) = 41,580/FLOORACTUAL HEIGHT: 30' -4" , 1 STORYACTUAL AREA: 8,395 MAIN FLOOR SF TYPE VB - NON- SPRINKLED-NFPA 13 (903.3.1.1)FIRE RESISTIVE REQUIREMENTS (TABLE 601 AND 602)STRUCTURAL FRAME: 1 HREXTERIOR BEARING WALL: 1 HRINTERIOR BEARING WALL: 0 HRINTERIOR NON-BEARING WALLS: 0 HRFLOOR CONSTRUCTION: 0 HRROOF CONSTRUCTION: 1 HR CEILINGEXTERIOR NON-BEARING WALLS BASED ON SEPARATION DIST.30' OR MORE FIRE SEPARATION DISTANCE: 0 HR10' TO 30' FIRE SEPARATION DISTANCE: 0 HR5' TO 10' FIRE SEPARATION DISTANCE: 1 HR5' OR LESS FIRE SEPARATION DISTANCE: 1 HR18'-0" MIN. CEILING HEIGHTS (1208.2)FLASHING REQUIRED TO PREVENT MOISTURE (1405.4)ROOF FLASHING REQUIRED (1503.2, 1507.5.7)FIRE SPRINKLER NOT REQUIRED THROUGHOUT (NFPA 13)- SECTION 903.3.1.1FIRE PROTECTION SYSTEMS:MEANS OF EGRESS REQUIREMENTSCOMMON PATH OF EGRESS TRAVEL (1014.3):-NOT TO EXCEED 100 FT - GROUP B (WITH SPRINKLER)2 EXITS REQUIRED (1021.2)7" MAX. RISE 11" MIN. TREAD - GROUP BSTAIR LANDING & WIDTH 44" MIN. (1009.4)VERTICAL RISE MAX. 12' (1009.10)EXIT TRAVEL DISTANCE (TABLE 1016.2):WITH SPRINKLER SYSTEMGROUP B = 300 FTCORRIDORS (TABLE 1018.1):WITH SPRINKLERS GROUP B = 0 HRMINIMUM WIDTH OF 44" (TABLE 1018.2)DEAD ENDS 50 FT MAX (1018.4)VERTICAL EXIT ENCLOSURES (1022.2): 3 STORIES OR LESS = 1 HR FIRE BARRIER, NOT REQUIRED TO BE ENCLOSEDACCESSIBLE ROUTE:ELEVATOR REQUIRED (1104.4)INTERIOR ENVIRONMENT:NATURAL VENTILATION REQUIRED (1203.4)8% MIN. OF NATURAL LIGHT REQUIRED (1205.2)FIRE RATED CONSTRUCTIONEXT. WALLS - FIRE SEPARATION DISTANCE (FSD) (TABLE 705.8)AREA OF UNPROTECTED OPENINGS IF FSD > 30' IS NOT REQ'D.IF FIRE SEPARATION DISTANCE (FSD) IS 3' TO < 5', 15% UNPROTECTED OPENINGSIF FIRE SEPARATION DISTANCE (FSD) IS 5' TO < 10', 25% UNPROTECTED OPENINGSIF FIRE SEPARATION DISTANCE (FSD) IS 10' TO < 15', 45% UNPROTECTED OPENINGSPARAPET NOT REQUIRED (705.11):- EXCEPTION 1: THE WALL IS NOT REQUIRED TO BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH TABLE 602 BECAUSE OF FIRE SEPARATION DISTANCE (<45%).SHAFT ENCLOSURE (713.4)CONNECTING 3 STORIES OR LESS: 1 HRCONNECTING 4 STORIES OR MORE: 2 HRFIRE PARTITION (710.4) CONTINUOUS TO UNDERSIDE OF DECK ABOVE OR RATED FLR/ROOF ASSEMBLY CAN HAVE HORIZONTAL OFFSETSHORIZONTAL ASSEMBLIES (711.4)CONTINUOUS WITHOUT OPENINGS/PENETRATIONS (EXCEPT PER 712.1, 714.4, 715, 1009.3 & 1022.1) OPENING REQUIREMENTS (TABLE 716.5)1 HR FIRE BARRIERS (SHAFTS, EXITS):1 HR OPENINGPROVIDE PORTABLE FIRE EXTINGUISHERS (906.1)1 HR FIRE PARTITION (DEMISING WALLS, ELEV. LOBBY):45 MIN. OPENING30 MIN FIRE PARTITIONS (CORRIDORS) 20 MIN OPENINGARCHITECTURE · PLANNING · DEVELOPMENT · INTERIORS1425 WEST MAIN ST. · SUITE A · BOZEMAN, MONTANA · 59715TELEPHONE: (406) 587-1204 · EMAIL: FHA@FHARCHITECTS.COM© 2021 FHA. It is unlawful to use any or all of these document without the expressed written consecnt of Faure Halvorsen Architects PC.A R C H I T E C T SF A U R E H A L V O R S E NDATE: 202110/13/2021 12:31:25PMG1.2CLIENT NAME, PROJECT LOCATIONLEGION INDOOR FACILITYPROJECT ADDRESS, CITY, STATE, ZIP CODEGENERALNOTESJOB NO: 00-000MAN DOOR HOLLOW METAL PAINTED TO MATCH EVERGREEN SIDINGOVERHEAD DOOR W/ LITES, HOLLOW METAL PAINTED TO MATCH EVERGREEN SIDINGMATTE BLACKTUFF RIB METAL ROOFTUFF RIB METAL SIDING, EVERGREENTIMBER COLUMNS