HomeMy WebLinkAbout35 S-A7-0 - DETAILS1/8" SLIPNOT NOSING,
GALVANIZED
STAIR PAN
STRINGER PER STRUCT.
11"1"VARIESCONCRETE TREAD
GRATE 1 1/4", SERRATED TEXTURE
STAIR PAN
STRINGER PER STRUCT.
11"1"VARIES1/8" SLIPNOT NOSING, GALVANIZED
F G
CLCL
TYP
10"3' - 6"
CL 10' - 2"VFY.2' - 2"VFY.2' - 8"7' - 6"2' - 0"1' - 0"
SLAB ON GRADE PER
STRUCTURAL
FINISH FLOOR AS PER SCHEDULE
GRAVEL AS PER
STRUCTURAL
COMPACTED FILL
FOUNDATION RIGID
INSULATION @
PERIMETER PER
INSULATION LEGEND
SIDING PER ELEVATIONS
MOISTURE BARRIER SEALED
AT TOP & BOTTOM OF
WALL & AT ALL OPENINGS
PLYWOOD SHEATHING
PER STRUCTURAL
5/8" GYP BOARD
CONCRETE FOOTING AS PER
STRUCTURAL
VAPOR BARRIER, SEAL
TO FOUND. WALL
• FINISHED FLOORING
• SLAB ON GRADE OVER
• VAPOR BARRIER UNDER ENTIRE SLAB
• RIGID INSULATION FOR 24" AROUND
PERIMETER FOUNDATION WALLS
TYPICAL 1st LEVEL FLOOR ASSEMBLY
TYPICAL EXTERIOR WALL ASSEMBLY
FOR AIR BARRIER CALK
BETWEEN STUDS &
STUDS TO FOUNDATION
• EXTERIOR FINISH MATERIAL PER ELEVATIONS
• MOISTURE BARRIER
• PLYWOOD SHEATHING
• WOOD FRAMING
• 2" MIN., R-14 MIN., CLOSED CELL
POLYURETHANE SPRAY INSULATION ON INSIDE
OF EXTERIOR SHEATHING (ACTS AS EXTERIOR
AIR BARRIER BUT MUST FOLLOW DETAIL AND
BLOCK UNDER WINDOWS & SEAL AROUND
ENTIRE WINDOW, ALSO ACTS AS INTERIOR
VAPOR BARRIER)
• 3-1/2", R-13 BATT INSULATION
• 5/8" GYP BOARD TAPED & SEALED
TROWEL FINISH TOP OF
ALL FOUNDATION WALLS
SET FRAMING FLUSH W/
EXT. FACE OF FND WALL
INSULATION PER
INSULATION LEGEND
SLOPE TO DRAIN
6" WOOD FRAMING
PER STRUCTURAL
TYP. 8" FOUNDATION WALL,
VERIFY SIZE AND PLACEMENT
PER STRUCTURAL
SLAB ON GRADE PER
STRUCTURAL
FINISH FLOOR PER
SCHEDULE, TBD
COMPACTED FILL
MOISTURE BARRIER
PLYWOOD SHEATHING
PER STRUCTURAL
CONCRETE FOOTING AS PER
STRUCTURAL
5/8" GYP BOARD
GRAVEL AS PER
STRUCTURAL
FOUNDATION RIGID
INSULATION @
PERIMETER PER
INSULATION LEGEND
VAPOR BARRIER SEAL
TO FOUND. WALL
FOR AIR BARRIER CAULK
BETWEEN STUDS & STUDS
TO FOUNDATION BRICK VENEER
(SEE STRUCTURAL FOR
VENEER ANCHORS)
WEEPS AT 24" O.C.
BUILDING WRAP LAP
OVER METAL
FLASHING -TYP.
CAVITY DRAINAGE MATERIAL
SET FRAMING FLUSH W/
INT.FACE OF FND. WALL
TROWEL FINISH TOP OF
ALL FOUNDATION WALLS
TYP. 10" FOUNDATION WALL,
VERIFY SIZE AND PLACEMENT
PER STRUCTURAL
6" WOOD FRAMING PER STRUCTURAL
T.O. WALL TO T.O. GRADE TYP.1' - 0"INSULATION PER
INSULATION LEGEND
PLAN -1ST LEVEL
100' -0 3/4"
10
1' - 6"CL1' - 6"4' - 0 1/2"JOB No.SHEET NUMBERPROJECT / OWNERARCHITECTLOCATI ARCHITECTS1007 E. MAIN SUITE 202 BOZEMAN MONTANA406-587-1139 FAX 587-7369COPYRIGHT LOCATI ARCHITECTS P.L.L.P.2020 ALL RIGHTS RESERVEDPROJECT MGR1930UNIVERSITY CROSSING - SOUTHS 19TH AVE & KAGY BLVDBOZEMAN, MTS-A7.0DETAILSXXXXXDETAIL
SCALE: 1 1/2" = 1'-0"S-A7.0 REF: 1 / S-A6.10
(CAST IN PLACE STAIR)1 DETAIL
SCALE: 1 1/2" = 1'-0"S-A7.0 REF: 1 / S-A6.10
(METAL GRATE TREAD STAIR)2
DETAIL
SCALE: 1/2" = 1'-0"S-A7.0 REF: 1 / S-A2.0
(ELECTRICAL METER ELEVATION)3
DETAIL
SCALE: 1 1/2" = 1'-0"S-A7.0
(WOOD STUD W/ SIDING @ FOUNDATION TYP.)5 DETAIL
SCALE: 1 1/2" = 1'-0"S-A7.0
(WOOD STUD W/ BRICK @ FOUNDATION TYP. @ GRADE)6 ISSUE#DATESP RESUBMIT44-13-22DETAIL
SCALE: 1/2" = 1'-0"S-A7.0 REF: 1 / S-A2.0
(GAS METER ELEVATION)4