Loading...
HomeMy WebLinkAbout15 C5.1 - CIVIL DETAILS04/13/2022ISOLATOR ROW PLUS(SEE DETAIL)PLACE MINIMUM 12.50' OF ADSPLUS125 WOVEN GEOTEXTILE OVER BEDDINGSTONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALLCHAMBER INLET ROWSPerimeterCBACONCEPTUAL ELEVATIONSMAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED):9.83MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC):3.83MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC):3.33MINIMUM ALLOWABLE GRADE (TOP OF RIGID CONCRETE PAVEMENT):3.33MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT):3.33TOP OF STONE:2.58TOP OF SC-310 CHAMBER:1.838" x 8" TOP MANIFOLD INVERT:0.7912" ISOLATOR ROW PLUS INVERT:0.58BOTTOM OF SC-310 CHAMBER:0.50BOTTOM OF STONE:0.00PROPOSED LAYOUT75STORMTECH SC-310 CHAMBERS28STORMTECH SC-310 END CAPS9STONE ABOVE (in)6STONE BELOW (in)40STONE VOID2729INSTALLED SYSTEM VOLUME (CF)(PERIMETER STONE INCLUDED)(COVER STONE INCLUDED)(BASE STONE INCLUDED)2170SYSTEM AREA (SF)237.7SYSTEM PERIMETER (ft)*INVERT ABOVE BASE OF CHAMBERMAX FLOWINVERT*DESCRIPTIONITEM ONLAYOUTPART TYPE0.90"12" BOTTOM PREFABRICATED END CAP, PART#: SC310EPE12BR / TYP OF ALL 12" ISOLATOR ROWPLUS CONNECTIONSAPREFABRICATED END CAP3.50"8" x 8" TOP MANIFOLD, MOLDED FITTINGSBMANIFOLD2.3 CFS IN30" DIAMETER (24.00" SUMP MIN)CNYLOPLAST (INLET W/ ISOPLUS ROW)NOMINAL CHAMBER SPECIFICATIONSSIZE (W X H X INSTALLED LENGTH)34.0" X 16.0" X 85.4" (864 mm X 406 mm X 2169 mm)CHAMBER STORAGE14.7 CUBIC FEET (0.42 m³)MINIMUM INSTALLED STORAGE*31.0 CUBIC FEET (0.88 m³)WEIGHT35.0 lbs.(16.8 kg)*ASSUMES 6" (152 mm) ABOVE, BELOW, AND BETWEEN CHAMBERSBUILD ROW IN THIS DIRECTIONSC-310 TECHNICAL SPECIFICATIONNTSOVERLAP NEXT CHAMBER HERE(OVER SMALL CORRUGATION)START END34.0"(864 mm)16.0"(406 mm)90.7" (2304 mm) ACTUAL LENGTH85.4" (2169 mm) INSTALLED LENGTHAABC9.9"(251 mm)15.6"(396 mm)PART #STUBABCSC310EPE06T / SC310EPE06TPC6" (150 mm)9.6" (244 mm)5.8" (147 mm)---SC310EPE06B / SC310EPE06BPC---0.5" (13 mm)SC310EPE08T / SC310EPE08TPC8" (200 mm)11.9" (302 mm)3.5" (89 mm)---SC310EPE08B / SC310EPE08BPC---0.6" (15 mm)SC310EPE10T / SC310EPE10TPC10" (250 mm)12.7" (323 mm)1.4" (36 mm)---SC310EPE10B / SC310EPE10BPC---0.7" (18 mm)SC310EPE12B12" (300 mm)13.5" (343 mm)---0.9" (23 mm)SC310EPE12BR12" (300 mm)13.5" (343 mm)---0.9" (23 mm)ALL STUBS, EXCEPT FOR THE SC310EPE12B ARE PLACED AT BOTTOM OF END CAP SUCH THAT THE OUTSIDE DIAMETER OFTHE STUB IS FLUSH WITH THE BOTTOM OF THE END CAP. FOR ADDITIONAL INFORMATION CONTACT STORMTECH AT1-888-892-2694.* FOR THE SC310EPE12B THE 12" (300 mm) STUB LIES BELOW THE BOTTOM OF THE END CAP APPROXIMATELY 0.25" (6 mm).BACKFILL MATERIAL SHOULD BE REMOVED FROM BELOW THE N-12 STUB SO THAT THE FITTING SITS LEVEL.NOTE: ALL DIMENSIONS ARE NOMINALPRE-FAB STUB AT BOTTOM OF END CAP WITH FLAMP END WITH "BR"PRE-FAB STUBS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B"PRE-FAB STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "T"PRE CORED END CAPS END WITH "PC"ISOLATOR ROW PLUS(SEE DETAIL)PLACE MINIMUM 12.50' OF ADSPLUS125 WOVEN GEOTEXTILE OVER BEDDINGSTONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALLCHAMBER INLET ROWSPerimeter42.09'18.17'36.78'16.16'ABCCONCEPTUAL ELEVATIONSMAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED):9.83MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC):3.83MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC):3.33MINIMUM ALLOWABLE GRADE (TOP OF RIGID CONCRETE PAVEMENT):3.33MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT):3.33TOP OF STONE:2.33TOP OF SC-310 CHAMBER:1.838" x 8" TOP MANIFOLD INVERT:0.7912" ISOLATOR ROW PLUS INVERT:0.58BOTTOM OF SC-310 CHAMBER:0.50BOTTOM OF STONE:0.00PROPOSED LAYOUT25STORMTECH SC-310 CHAMBERS10STORMTECH SC-310 END CAPS6STONE ABOVE (in)6STONE BELOW (in)40STONE VOID935INSTALLED SYSTEM VOLUME (CF)(PERIMETER STONE INCLUDED)(COVER STONE INCLUDED)(BASE STONE INCLUDED)765SYSTEM AREA (SF)120.5SYSTEM PERIMETER (ft)MAX FLOWINVERT*DESCRIPTIONITEM ONLAYOUTPART TYPE0.90"12" BOTTOM PREFABRICATED END CAP, PART#: SC310EPE12BR / TYP OF ALL 12" ISOLATOR ROWPLUS CONNECTIONSAPREFABRICATED END CAP3.50"8" x 8" TOP MANIFOLD, MOLDED FITTINGSBMANIFOLD2.3 CFS IN30" DIAMETER (24.00" SUMP MIN)CNYLOPLAST (INLET W/ ISOPLUS ROW)*INVERT ABOVE BASE OF CHAMBER