Loading...
HomeMy WebLinkAboutA5.1_ADU_Floor_PlansBF1225' - 6"1A5.1GARAGE101A2A5.1EDTENANT GARAGE102MECH103CONCRETE DRIVEWAYMIN 2% SLOPEPOWDER1045/8" TYPE X GWB IN GARAGE INTERIOR & CEILING, TYPCONCRETE GARAGE SLAB3/16" : 12" SLOPE8' - 2"2' - 1"10' - 6"4' - 9"SELF-CLOSING, 1 3/8" SOLID CORE DOOR4S1.1CSTORAGE3A5.1BEAM ABOVE3' - 0"4A5.1EXISTING FENCE ON PROPERTY LINEEXISTING FENCE ON PROPERTY LINECONC WALKWAY AROUND PERIMETERGAS METERELEC METERBEAM ABOVE39' - 6"MAIN WATERLINE FROM HOUSE4' - 6"11' - 9"5' - 10 1/2"8' - 4 1/2"9' - 0"15' - 7"8' - 7"15' - 4"18' - 6"ROOF OVERHANGROOF OVERHANG2 HR FIRE RATED TYPE X GWB 5/8"OVER 7/16" OSB FOR SHEAR5S1.13S1.1BF121A5.1A2A5.125' - 6"E26' - 0"ROOF DECKDBOOKSHELVES ON CASTERS.8' - 4 1/2"5' - 10 1/2"11' - 9"12' - 0"4:12 VAULT3:12 VAULTRIDGE BEAM ABOVE10' - 1"2' - 8"BATH204FLEX203LIVING202KITCHEN201BEDROOM2053" / 12"5" / 12"5" / 12"A7.148' - 8"4' - 1"CA7.1356A7.17RANGE HOOD ABOVE3A5.14A5.1SLOPE 3/16" : 12"8' - 0 1/2"4' - 0"5' - 10 1/2"4' - 6"11' - 9"5' - 10 1/2"8' - 4 1/2"9' - 0"TOP39' - 6"4' - 1"8' - 8"DIMENSIONS ARE TO GRID, FACE OF STUD, OR CENTER OF COLUMN & DOOR/WINDOW OPENINGS. VERIFY ALL OPENINGS WITH ROUGH OPENING REQUIREMENTS.GARAGE SHALL HAVE 5/8" 'TYPE X' GWB AT HOUSE COMMON WALLS AND GARAGE DOORS SHALL HAVE SELF-CLOSING HINGES OR OTHER SELF-CLOSING DEVICE.GRID LINES ARE PLACED AT EXTERIOR FACE OF FRAMING.BATHROOMS REQUIRE FANS TO BE VENTED DIRECTLY TO EXTERIOR, MIN. 50CFM.NO DUCTS TO BE RUN THROUGH GARAGE WITH ANY OPENINGS.FIREBLOCKING VERTICALLY AT FLOOR AND CEILINGS REQUIRED, HORIZONTALLY AT INTERVALS NO GREATER THAN 10'. CONCEALED SPACES (SOFFIT, DROP CEILINGS, MECH. CHASES, ETC.) BETWEEN VERTICAL AND HORIZONTAL SPACE SHALL HAVE FIREBLOCKING. THE SMOKE DEVELOPED INDEX FOR WALLS AND CEILINGS SHALL NOT HAVE AN INDEX GREATER THAN 450. (R302.9.2)THE FLAME SPREAD FOR WALLS AND CEILINGS FINISHED TO BE NOT GREATER THAN 200. (R302.9.1). WATER HEATER REQ'D TO BE 74 GAL. FOR THE FIRST HOUR PER 2018 UPC TABLE 501.1 (2)FOUNDATION FLOOR FRAMING INSPECTION APPROVAL REQUIRED (INCLUDINGSUBFLOOR SHEAR WALLS) PRIOR TO INSTALLATION OF FIRST FLOOR SHEATHING. (IRC R109.4)CLOTHES WASHER, DISHWASHER, AND REFRIDGERATOR TO HAVE WATER HAMER ARRESTORS INSTALLED.ADU USE TABLE IN RESIDENTIAL ZONING DISTRICTS. "LIVING AREA" DEFINED AS "ALL FLOOR AREA EXCLUSIVE OF AREAS WITH A SLOPED CEILING LESS THAN THREE FEET IN HEIGHT, STAIRWELLS, AND EXTERIOR DECKS. SEC. 38.360.040.1.2.3.4.5.6.7.8.9.10.11.12.GENERAL NOTES:CONSTRUCTIVE SOLUTIONS, INC COPYRIGHT 2022PROJECT #:PHASEPRE SDDDCDDATEPO BOX 11529, BOZEMAN, MT 59719406 404-1560 www.constructivesolutionsmt.com24X365/26/2022 5:36:06 PM5/26/20225:36:06PMA3.1FLOOR PLANSSOUTH 5TH ADU809 S 5TH AVEBOZEMAN, MT 59715DESIGN DEVELOPEMENT--2-22-22-N08'12'16'4'Graphic Scale: 1 inch = 4 feet1/4" = 1'-0"A3.11LEVEL 11/4" = 1'-0"A3.12LEVEL 2