Loading...
HomeMy WebLinkAbout007--A2.3 Basement Floor PlanWDUPWDUP110 PERMANENTLY WIRED, INTERCONNECTED SMOKE DETECTOR WITH BATTERY BACKUP AND CARBON MONIXIDE ALARMSDSTAIR WIDTHSHALL NOT BE LESS THAN 36" IN CLEAR WIDTH. (IRC-R311.7.1)TREADS & RISERSTHE MAX. RISER HEIGHT SHALL BE 7-3/4" (IRC-R311.7.5.1) AND THE MIN. TREAD DEPTH SHALL BE 10". (IRC-R311.7.5.2)WINDER TREADSSHALL HAVE A MIN. TREAD DEPTH OF 10" MEASURED AT A POINT 12" FROM THE SIDE WHERE THE TREADS ARE NARROWER. WINDER TREADS SHALL HAVE A MIN. TREAD DEPTH OF 6" AT ANY POINT. (IRC-R311.7.5.2)LANDING WIDTHSHALL NOT BE LESS THAN THE STAIRWAY OR DOOR SERVED. EVERY LANDING SHALL HAVE A MIN. DIM. OF 36" MEASURED IN THE DIRECTION OF TRAVEL. (IRC-R311.7.6)HANDRAIL HEIGHTSHALL BE A MIN. OF 34" AND A MAX. OF 38" MEASURED VERTICALLY FROM THE NOSING OF THE TREADS, AND SHALL BE PROVIDED ON AT LEAST ONE SIDE OF STAIRWAYS. (IRC-R311.7.8.1)CONTINUITYHANDRAILS FOR STAIRWAYS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT, FROM A POINT DIRECTLY ABOVE THE TOP RISER OF THE FLIGHT TO A POINT DIRECTLY ABOVE THE LOWEST RISER OF THE FLIGHT. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS OR SAFETY TERMINALS. HANDRAILS ADJACENT TO A WALL SHALL HAVE A SPACE OF NOT LESS THAN 1-1/2" BETWEEN THE WALL AND THE HANDRAIL. (IRC-311.7.8.2)GUARDRAIL HEIGHTSHALL NOT BE LESS THAN 36". (IRC-R312.1.2)RAIL SPACINGRAILS SHALL BE SPACED SO AS NOT TO ALLOW PASSAGE OF A SPHERE 4" IN DIA. (IRC-R312.1.3) THE TRIANGULAR OPENING AT THE OPEN SIDE OF THE STAIR, FORMED BY THE RISER, TREAD AND BOTTOM RAIL OF A GUARD, SHALL NOT ALLOW THE PASSAGE OF A SPHERE 6 INCHES IN DIAMETER. (IRC-312.1.3 -1)GUARDS ON THE OPEN SIDES OF THE STAIRS SHALL NOT HAVE OPENINGS THAT ALLOW PASSAGE OF A SPHERE 4-3/8 INCHES IN DIAMETER. (IRC-312.1.3 -2) R312.2 WINDOW FALL PROTECTIONIN DWELLING UNITS, WHERE THE TOP OF THE SILL OF AN OPERABLE WINDOW OPENING IS LOCATED LESS THAN 24 INCHES ABOVE THE FINISHED FLOOR AND GREATER THAN 72 INCHES ABOVE THE FINISHED GRADE OR OTHER SURFACE BELOW ON THE EXTERIOR OF THE BUILDING, THE OPERABLE WINDOW SHALL COMPLY WITH ONE OF THE FOLLOWING1. OPERABLE WINDOW OPENINGS WILL NOT ALLOW A 4-INCH DIAMITER SPHERE TO PASS THROUGH WHERE THE OPENINGS ARE IN THEIR LARGEST POSITION2. OPERABLE WINDOWS ARE PORIVDED WITH WINDOW FALL PREVENTION DEVICES THAT COMPLY WITH ASTM F20903. OPERABLE WINDOWS ARE PROVIDED WITH WINDOW OPENING CONTROL DEVICES THAT COMPLY WITH SECTION R312.2.2AABBCCDDEE3344556677FLEX ROOM1-001BATH1-002BED 31-003BED 41-004LAUNDRY1-005FLEX ROOM2-001BATH2-002BED 32-003BED 42-004LAUNDRY2-005A6.11A6.22A6.12A6.32EGRESSWINDOW WELLEGRESSWINDOW WELLWINDOW WELLWINDOW WELLAA5.1AA5.1BA5.1BA5.1CA5.2CA5.2EGRESSWINDOW WELLMECH.1-006EGRESSWINDOW WELLSDSDSDSDSDSDWHWHSESE17R@7 3/8"16T@11"17R@7 3/8"16T@11"1A9.41A9.41A9.41A9.4ACC6.11ACC6.12AABBCCDDEE3344556677FLEX ROOM1-001BATH1-002BED 31-003BED 41-004LAUNDRY1-005FLEX ROOM2-001BATH2-002BED 32-003BED 42-004LAUNDRY2-005EGRESSWINDOW WELLEGRESSWINDOW WELLWINDOW WELLWINDOW WELL1-00311-00411-00511-00211-00611-004A1-001A1-001C2-0312-00412-00612-001A2-001C1-001B2-00212-001B2-004A1-003A2-003AEGRESSWINDOW WELLMECH.1-006EGRESSWINDOW WELLSDSDSDMECH.2-006SDSDSDWH22.4WH22.422.722.722.522.5SESE26.226.22-006122.822.86.56.59.49.46.16.15.15.12' - 6 1/2"2' - 6 1/2"17R@7 3/8"16T@11"17R@7 3/8"16T@11"1--00421-00329.49.42--00422-00322345678910FEDCBAGH1PROJECT NO:DATE:20011-B05/12/2022All reports, drawings, specifications, computer files, field data, notes, other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect, LocalElementArchitects, LLC. The Architect shall retain all common law, statutory and other reserved rights, including copyright thereto. The use of this drawing shall be restricted to the original site for which it was prepared and publication thereof is expressly limited to such use. Reuse, reproduction or publication by any method is prohibited without written consent from LocalElementArchitects, LLC. NOT FOR CONSTRUCTION5/12/2022 2:04:23 PM C:\Users\chris\OneDrive\Documents\21001-B-113 S.7th Townhomes_chrisTMMND.rvt119 S. 7TH TOWNHOMES119 S. 7TH AVEBOZEMAN MT, 59715A2.4NOTED BASEMENTFLOOR PLANWINDOW FALL PROTECTIONSTAIR & HANDRAIL NOTESSMOKE DETECTOR LEGENDUNIT 1 AREA CALCULATIONSUNIT 1 RESIDENCEBASEMENT -LIVABLEUNIT 1 BASEMENT 935 SFBASEMENT - LIVABLE: 1 935 SFLIVABLE UNIT 1 MAIN FLOOR 805 SFLIVABLE UNIT 1 SECOND FLOOR 804 SFLIVABLE: 2 1609 SFUNIT 1 RESIDENCE 2544 SFGrand total 2544 SFUNIT 2 AREA CALCULATIONSUNIT 2 RESIDENCEBASEMENT -LIVABLEUNIT 2 BASEMENT 935 SFBASEMENT - LIVABLE: 1 935 SFLIVABLE UNIT 2 MAIN FLOOR 804 SFLIVABLE UNIT 2 SECOND FLOOR 804 SFLIVABLE: 2 1609 SFUNIT 2 RESIDENCE 2544 SFGrand total 2544 SFSCALE: 3/16" = 1'-0"1NOTED BASEMENT FLOORPLANNORTHKEYNOTESREVISIONSNO. DATE DESCRIPTION