Loading...
HomeMy WebLinkAboutP.1PlumbingPlanssHWR CW HW CW HW CWHWCWHWHWR CW HW HWRHWCWGWsdsdsdsdNGNGv vv v v vssssssss ss ss sdsdsdsdsdsdsdsdsdP-1 general notes A.COORDINATE ALL WORK WITH OTHER TRADES. ADDITIONAL COMPENSATION OR TIME WILL NOT BE GRANTED DUE TO LACK OF COORDINATION BETWEEN TRADES B.ALL WORK SHALL BE COMPLETED IN A PROFESSIONAL AND WORKMANSHIP TYPE MANNER. ANY WORK THAT IS SUB STANDAR WILL NEED TO BE REDONE AT NO ADDITIONAL EXPENSE TO THE OWNER. C.UNLESS OTHERWISE NOTED, ALL CW AND HW PIPING CONNECTIONS TO FIXTURES ARE 1/2". D. UNLESS OTHERWISE NOTED, ALL SANITARY SEWER, STORM DRAIN, DRAIN, SHALL SLOPE AT 1/4" PER FT TO DRAIN. PLUMBING PLAN N 13524PE S T A T E OF MONTANA PROF ESSI ONAL E N G IN EEREDRB ERGECD.YAJ3" STORM DRAIN UP TO RD-1 AND OFD-1 SEE ARCHITECTURAL SHEETS FOR INSTALLATION DETAILS 3" STORM DRAIN UP TO RD-1 AND OFD-1 SEE ARCHITECTURAL SHEETS FOR INSTALLATION DETAILS 3" STORM DRAIN UP TO RD-1 AND OFD-1 SEE ARCHITECTURAL SHEETS FOR INSTALLATION DETAILS 3" STORM DRAIN UP TO RD-1 AND OFD-1 SEE ARCHITECTURAL SHEETS FOR INSTALLATION DETAILS DSN AT 24" ABOVE GRADE DSN AT 24" ABOVE GRADE 4" SANITARY SEWER SEE CIVIL FOR CONTINUATION 4" SAND/OIL WASTE SEE CIVIL FOR CONNECTION TO SAND OIL INTERCEPTOR DSN AT 24" ABOVE GRADE DSN AT 24" ABOVE GRADE DSN AT 24" ABOVE GRADE 3" STORM DRAIN SEE CIVIL FOR CONTINUATION 3" STORM DRAIN SEE CIVIL FOR CONTINUATION FD-2 FCO PROVIDE DOUBLE OUTLET SUPPLY STOP ON HW FOR BOTH SINK AND DISHWASHER 3/4" 3/4" 1/2" 3/4" 3/4" 1/2" 1" 1" UNDERGROUND DOMESTIC WATER SUPPLY TYPE K COPPER SEE WATER SERVICE ENTRANCE DETAIL HWH-1 IN BONUS ROOM ABOVE GARAGE SEE DETAIL 1-1/4" AT BOTTOM OF TRUSSES 3/4" 3/4" UP TO RTU RTU ON ROOF SEE SHEET M-2 FOR PIPING CONNECTIONS RTU ON ROOF SEE SHEET M-2 FOR PIPING CONNECTIONS WH-1 FD-2 2" VENT UP 4" VENT THROUGH ROOF. SEE DETAIL. 2" VENT UP 4" VENT THROUGH ROOF. SEE DETAIL. ARCHITECTS STUDIO CH JC - COPYRIGHT 2019 THESE DOCUMENTS, IN PART OR IN WHOLE, AND THE DESIGN THEY REPRESENT; ARE THE SOLE PROPERTY OF STUDIO 4 ARCHITECTS. THESE DOCUMENTS ARE INTENDED FOR THE PROJECT ON THE SITE INDICATED. ANY USE, REPRODUCTION, MODIFICATION, OR ADAPTATION WITHOUT THE EXPRESS WRITTEN CONSENT OF STUDIO 4 ARCHITECTS IS STRICTLY PROHIBITED. - - - 11-3-21 7-8-21 27 Shiloh Road Suite 8 Billings, MT 59106 ph: 406.656.1714 fx: 406.656.1715 web: studio4architects.com Bozeman, Montana PROJECT: C DATES: PRE: CRS: CHECKED BY: DRAWN BY: PROJECT NO. SHEET: REV: REV: CDS: SET:Stillwater Hospice1" STUB OUT FOR IRRIGATION 3/4" NAT GAS TO UH-1 SEE SHEET M-1 L-1 WC-1 L-1 WC-1 S-1 3" STORM DRAIN SEE CIVIL FOR CONTINUATION 3" STORM DRAIN SEE CIVIL FOR CONTINUATION 3/4" UP TO RTU 3" STORM DRAIN UNDER SLAB 3" STORM DRAIN UNDER SLAB UNDERGROUND NAT GAS BY UTILITY CO. NAT GAS METER BY UTILITY CO. 305 MBH LOAD PIPING ABOVE CEILING WATER HAMMER ARRESTOR 3" 4" 2"