E3.1ElectricalPowerPlan
REFR.A ATVJ J J JJ M M ODO ODO M M J PF M J J 118 DME 102 CONFERENCE 107 OFFICE 108 OFFICE 109 OFFICE 110 OFFICE 106 NURSE 111 MENS 112 WOMENS 114 OFFICE 115 OFFICE 113 STORAGE 116 OFFICE 101 RECEPTION 105 BREAK 103 COPY 104 MED ST 117 BEREAVEMENT GFI GFI GFI GFI GFI WP GFI WP GFI GFI GFI GFI GFI GFI WP 1 METER SOCKET GFI WP AC GFI WP 2 3 3 3 2 3 A1-17 A1-17 A1-17 A1-17 A1-19 A1-19 A1-19 A1-19 A1-21 A1-23A1-21 A1-21 A1-23 A1-23 A1-23A1-21 A1-12 A1-12 A1-12 A1-12 A1-12 A1-8 A1-8 A1-8 A1-8 A1-6 A1-6 A1-6 A1-6 A1-4 A1-4 A1-4 A1-4 A1-2 A1-2 A1-47 A1-39 A1-39 A1-39 A1-41 A1-43 A1-43A1-43 A1-43 A1-43 A1-45A1-45 A1-45 A1-47 A1-47 A1-47 A1-51 A1-51 A1-49 A1-27 A1-25 A1-29 A1-31 A1-31 A1-47 A1-31 A1-31 A1-35 A1-35 A1-37 A1-37 A1-37 A1-33 A1-33 A1-33 A1-33 A1-2 A1-34 A1-36 A1-32 A1-32 A1-32 A1-30 A1-30 A1-30 A1-30 A1-1 A1-1 EF-1 EF-24 4 A1-38 UH-1 A1 5 44" 65 A1-10 7 A1-25 AC A1-29 A1-53 AC AC A1-2 GFI GFI 8 A1-32 A1-30 A1-30 9 A1-31 A1-47 10 11 12 13 A1-45 14A1-45 15 A1-41 A1-41 LCP A1-13 A1-35 16 16 GENERAL ELECTRICAL POWER & SYSTEMS NOTES A. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS. B. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS, WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF HOLES TO THE SATISFACTION OF THE ARCHITECT/ENGINEER. C. LOW VOLTAGE CABLES (LIGHTING CONTROLS) ABOVE ACCESSIBLE CEILINGS SHALL BE SUPPORTED USING J-HOOKS AT INTERVALS NOT TO EXCEED 48" OC, UNO. D. ANY MECHANICAL EQUIPMENT THAT DOES NOT HAVE A DISCONNECT SHOWN AT DEVICE ON PLAN IS PROVIDED W/ A FACTORY DISCONNECT. EC TO CONNECT TO DISCONNECT ELECTRICALLY COMPLETE, VIA THE CIRCUIT SHOWN ON PLAN. SEE MEP COORDINATION SCHEDULE ON E0.2 FOR ADDITIONAL DETAILS. E. ALL BUILDING EXTERIOR RECEPTACLES SHALL BE: GFI STYLE, WEATHER RESISTIVE CONSTRUCTION AND FEATURE A METALLIC WEATHERPROOF-IN- USE COVER THAT IS CAPABLE OF ACCEPTING A STANDARD HASP STYLE PADLOCK, AS WELL AS ANY ADDITIONAL FEATURES WHEN CALLED FOR ON PLANS. 315 North 25th Street, Suite 102 Billings, MT 59101 Phone: 406.656.6000 Project # 6804.001 COPYRIGHT © 2021 THESE DOCUMENTS, IN PART OR IN WHOLE, AND THE DESIGN THEY REPRESENT; ARE THE SOLE PROPERTY OF STUDIO 4 ARCHITECTS. THESE DOCUMENTS ARE INTENDED FOR THE PROJECT ON THE SITE INDICATED. ANY USE, REPRODUCTION, MODIFICATION, OR ADAPTATION WITHOUT THE EXPRESS WRITTEN CONSENT OF STUDIO 4 ARCHITECTS IS STRICTLY PROHIBITED. project: set: dates: sheet: PRE: CRS: CDS: REV: REV: PROJECT NO. DRAWN BY: CHECKED BY: 2-22-21 - - - 27 Shiloh Road Suite 8 Billings, MT 59106 ph: 406.656.1714 fx: 406.656.1715 web: studio4architects.com STUDIO ARCHITECTS 8-6-21 e3.1PRELIMINARY -NOT FOR CONSTRUCTIONTJ JK 2104Stillwater HospiceEvergreen DrivePLANBozeman, Mt1/4" = 1'-0"1 ELECTRICAL POWER AND SYSTEMS PLAN –1ST FLOOR KEY NOTES:# N 1 POWER CONNECTION FOR WALL MOUNTED DISPLAY SCREEN. ROUTE A 1 1/2" CONDUIT FROM THE LOW VOLTAGE SIDE OF TV ROUGH-IN BOX TO A JUNCTION BOX AT 18" AFF AND FROM THE JUNCTION BOX TO THE FLOOR BOXES IN THE ROOM. 2 EC TO PROVIDE POWER CONNECTION TO OH DOOR MOTOR. VERIFY FINAL MOTOR LOCATION W/ INSTALLER PRIOR TO ROUGH-IN AND PROVIDE APPROPRIATE CONNECTION. 3 PROVIDE ROUGH-IN FOR OVERHEAD DOOR SAFETY BEAMS AT 6" AFF ON BOTH SIDES OF DOOR AND AN 1/2 EMPTY C. W/ PULL STRING ROUTED FROM EACH BOX TO CORRESPONDING DOOR MOTOR FOR CABLING BY OH DOOR INSTALLER. COORDINATE WITH DOOR INSTALLER FOR ADDITIONAL DETAILS AND PROVIDE ALL REQUIRED ELECTRICAL CONNECTIONS TO SUPPORT A COMPLETE AND OPERATION OH DOOR SYSTEM. 4 EC TO PROVIDE POWER CONNECTION FOR EXHAUST FAN THAT IS PROVIDED BY MC. EXHAUST FAN IS TO BE CONTROLLED VIA LIGHTING CONTROL IN THE ROOM. 5 PROVIDE A 5ma GFCI BREAKER IN PANEL TO SERVE LOAD. 6 SPLIT WIRE DEVICE SUCH THAT TOP HALF IS SWITCHED FOR INTERFACE WITH GARBAGE DISPOSAL AND BOTTOM IS UN-SWITCHED FOR USE WITH DISHWASHER. 7 EC TO PROVIDE A 4’X4’X3/4” ½ SHEET OF FIRE TREATED PLYWOOD MOUNTED ON THE WALL AT THIS LOCATION FOR USE BY SERVING TELECOM SERVICE PROVIDER TO MOUNT EQUIPMENT UPON. LOCATE BOTTOM OF PLYWOOD AT 30” AFF. PROVIDE A GROUND BAR AND GROUND CONDUCTOR PER DETAIL ON e0.2, LOCATING GND BAR AT 4’ AFF. 8 MOUNT ALL RECEPTACLES IN THE DME/ GARAGE AREA AT 48”, UNO 9 CONNECT SWITCH COMPLETE TO EF-3 LOCATED ON THE ROOF, WHICH SERVES THE DME/ GARAGE SPACE. PROVIDE A MACHINE PRINTED LABEL ON COVER PLATE THAT READS “EXHAUST FAN”. 10 EMPTY 2” C. W/ PULL LINE FOR TELECOM SERVICE ENTRANCE POINT INTO THE BUILDING. CONDUIT SHALL BE ROUTED FROM LOCATION THAT IS 6” ABOVE FINISHED FLOOR UNDERGROUND AND TO TELEPHONE PEDESTAL ON SITE. UTILIZE LONG RADII SWEEPS FOR ALL CONDUIT TRANSITIONS. SEE SITE AND CIVIL PLANS FOR EXISTING PEDESTAL LOCATION. EC SHALL CLOSELY COORDINATE WITH SERVING UTILITY FOR ADDITIONAL DETAILS. 11 TV BOX LOW VOLTAGE CONDUITS SHALL BE ROUTED AS PER DESCRIPTION ON LEGEND WITH (1) CONDUIT TO ACCESSIBLE CEILING SPACE AND THE OTHER TO JUNCTION BOX NOTED BY KEYNOTE #1, THAT CONTAINS CONDUITS WHICH ARE ROUTED TO THE FLOOR BOX IN THE ROOM. 12 POWER FOR MOTORIZED PROJECTION SCREEN, INSTALLED IN THE CEILING ALONG THIS WALL. EC TO VERIFY FINAL SCREEN LOCATION PRIOR TO ROUGH-IN OF POWER. 13 EC TO PROVIDE A 4” SQ BACK BOX W/ 1 GANG MUD RING LOCATED AT 48” FOR USE WITH MOTORIZED PROJECTION SCREEN SWITCH THAT IS PROVIDED WITH SCREEN, WIRED COMPLETE BY EC. ROUTE A 3/4” C. W/ PULL LINE FROM SWITCH LOCATION TO THE OVERHEAD PROJECTION SCREEN FOR USE WITH THE EC PROVIDED CONDUCTORS. CONDUCTORS SIZE AND QUANTITY SHALL BE PROVIDED AS PER MANUFACTURERS WRITTEN INSTRUCTION BETWEEN THE LOCATIONS, BASE BID SHALL BE (4)-#12’S. EC TO VERIFY FINAL SCREEN LOCATION AND WIDTH PRIOR TO ROUGH-IN OF WALL MOUNTED CONTROL SWITCH, SUCH THAT SWITCH WILL NOT BE LOCATED BEHIND THE SCREEN WHEN EXTENDED. 14 CEILING RECEPTACLE IS FOR OWNER PROVIDED OH PROJECTOR. EC TO VERIFY FINAL DESIRED LOCATION OF PROJECTOR W/ OWNER PRIOR TO TRIM OUT OF POWER IN THE FACE OF THE CEILING TILE. 15 MOUNT DEVICE IN THE BACK OF CASEWORK/ CABINETRY AND CONCEAL ALL RACEWAYS FULLY WITHIN. EC TO COORDINATE W/ CASEWORK INSTALLER FOR ROUTING PATHS AND FINAL CONSTRUCTION DETAILS. 16 EC TO PROVIDE ROUGH-IN AT THE DOOR HEADER CONSISTING OF 1/2” C. FOR FUTURE POWER CONNECTION TO A HANDICAP DOOR OPERATOR AT THIS LOCATION. ROUTE RACEWAY INTO NEAREST ACCESSIBLE CEILING SPACE AND TERMINATE ON A 4” SQ BOX FOR FUTURE EXTENSION/ USE. VERIFY FINAL POWER CONNECTION LOCATION IN DOOR HEADER PRIOR TO ROUGH-IN WITH DOOR HARDWARE INSTALLER FOR BEST USE IN THE FUTURE.